Dickson TM320

Dickson TM320 Temperature and Humidity Data Logger

Manual de instrucciones

1. Introducción

The Dickson TM320 is a versatile data logger designed to accurately monitor and record temperature and humidity levels. Featuring a large display for real-time readings, audio/visual alarms, and convenient data transfer options via USB and flash card, it provides essential environmental monitoring for various applications. Its user-friendly design ensures ease of use and reliable performance.

  • USB Enabled Download: Easily transfer recorded data to a computer.
  • Flash Memory Data Transfer Capability: Utilize flash cards for convenient data retrieval.
  • Jumbo Display: Clear and easy-to-read real-time measurements.
  • Fácil de usar: Intuitive interface for straightforward operation.

2. Información de seguridad

Please read all safety instructions before operating the device. Failure to do so may result in damage to the device or personal injury.

  • No exponga el dispositivo a temperaturas extremas fuera de su rango operativo especificado.
  • Avoid direct contact with water or high humidity environments beyond the non-condensing range.
  • Utilice únicamente fuentes de alimentación y accesorios especificados.
  • No intente abrir ni reparar el dispositivo usted mismo. Encargue cualquier reparación a personal cualificado.
  • Mantener fuera del alcance de los niños.

3. Contenido del paquete

Verifique que todos los artículos estén presentes en el paquete:

  • Dickson TM320 Data Logger
  • Manual de instrucciones (este documento)
  • Cable USB (se puede vender por separado)
  • SD Card (may be sold separately)
  • Batteries (may be pre-installed or included)

4. Producto terminadoview

Frente view of Dickson TM320 Data Logger with display showing '0.0' and battery indicator.

Figura 4.1: Frente View. Shows the large digital display, 'DICKSON' branding, and three control buttons: MIN/MAX, ALARM, and SAVE.

Lado view of Dickson TM320 Data Logger showing USB port, sensor input, and ventilation slots.

Figura 4.2: Lado View con puertos. Illustrates the mini-USB port for data transfer and external sensor input jacks, along with ventilation for internal sensors.

Atrás view of Dickson TM320 Data Logger showing battery compartment and mounting holes.

Figura 4.3: Atrás View. Displays the battery compartment cover and keyhole slots for wall mounting.

Arriba view of Dickson TM320 Data Logger showing the SD card slot.

Figura 4.4: Arriba View. Shows the slot for inserting an SD card for data storage and transfer.

5. Configuración

5.1. Instalación de la batería

  1. Localice el compartimento de la batería en la parte posterior del dispositivo (consulte la Figura 4.3).
  2. Deslice la tapa de la batería para abrirla.
  3. Insert the required batteries (typically AA or AAA, check compartment for type) ensuring correct polarity (+/-).
  4. Cierre bien la tapa de la batería.

5.2. Encendido inicial

The device should power on automatically once batteries are installed. The display will illuminate, showing current readings or a startup sequence.

5.3. Montaje del dispositivo

The TM320 can be placed on a flat surface or mounted on a wall:

  • Colocación de superficie: Ensure the device is placed on a stable, level surface away from direct heat sources or extreme drafts.
  • Montaje en pared: Use appropriate screws (not included) with the keyhole slots on the back of the device (refer to Figure 4.3) to secure it to a wall. Ensure it is mounted in a location representative of the environment you wish to monitor.

6. Operación

6.1. Comprensión de la pantalla

The jumbo display provides real-time information:

  • Lectura actual: Shows the live temperature or humidity value.
  • Unidades: Indicates Fahrenheit (F) or Celsius (C) for temperature, and %RH for humidity.
  • Indicador de batería: Muestra la vida útil restante de la batería.
  • CH (canal): Indicates which channel is currently displayed (e.g., CH 1 for temperature, CH 2 for humidity).

6.2. Funciones de los botones

  • Botón MIN/MAX: Press to cycle through minimum, maximum, and current readings for both temperature and humidity. Hold to reset min/max values.
  • Botón de alarma: Presione para view current alarm settings. Hold to enter alarm setting mode (refer to section 6.4).
  • Botón GUARDAR: Press to manually save a data point.

6.3. Registro de datos

The TM320 automatically logs data at a pre-set interval. Data can be viewed on the display or downloaded to a computer.

6.4. Configuración de alarmas

The device features audio/visual alarms for out-of-range conditions.

  1. Mantenga pulsado el ALARMA button until the alarm setting mode is activated.
  2. Utilice el MÍNIMO MÁXIMO button to navigate between temperature and humidity alarm settings (high/low).
  3. Utilice el AHORRAR button to adjust the alarm threshold values.
  4. Prensa ALARMA nuevamente para confirmar y salir del modo de configuración.

6.5. Descarga de datos (USB)

  1. Connect the TM320 to your computer using a compatible USB cable (refer to Figure 4.2 for port location).
  2. The device should be recognized as a removable storage device or require specific Dickson software (refer to manufacturer's websitio para software).
  3. Follow the software instructions to download and analyze the logged data.

6.6. Data Transfer (Flash Card)

If your model supports flash card data recovery:

  1. Insert a compatible SD card into the SD card slot (refer to Figure 4.4).
  2. The device may automatically transfer data or require a specific button press (consult software/manual for details).
  3. Remove the SD card and insert it into a computer's card reader to access the data.

7. Mantenimiento

7.1. Limpieza

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no liquid enters the sensor vents or ports.

7.2. Reemplazo de la batería

Reemplace las baterías cuando aparezca el indicador de batería baja en la pantalla. Siga los pasos de instalación de las baterías que se indican en la Sección 5.1.

7.3. Almacenamiento

Cuando no lo utilice durante períodos prolongados, retire las baterías y guarde el dispositivo en un lugar fresco y seco, alejado de la luz solar directa y de temperaturas extremas.

8. Solución de problemas

ProblemaPosible causaSolución
El dispositivo no se enciende.Baterías muertas o instaladas incorrectamente.Verifique la polaridad de la batería; reemplácela con baterías nuevas.
No data is being logged.Device not powered on; memory full; logging paused.Ensure device is on; download data to clear memory; check software settings for logging status.
Display shows 'Err' or abnormal readings.Sensor malfunction; out of range conditions.Move device to a stable environment; contact support if error persists.
Cannot download data via USB.Incorrect cable; driver issue; software not installed.Ensure correct USB cable; install necessary drivers/software from Dickson websitio.
La alarma no suena.Alarm disabled; volume too low; thresholds set incorrectly.Check alarm settings (Section 6.4); ensure alarm is enabled and thresholds are appropriate.

9. Especificaciones

CaracterísticaDetalle
Número de modeloTM320
Rango de temperatura-4 a 158 °F (-20 a 70 °C)
Rango de humedad0-95 % HR (sin condensación)
FabricanteDickson Unigage Inc.
Dimensiones del producto19.56 x 16.51 x 8.89 cm (7.7 x 6.5 x 3.5 pulgadas)
Peso del producto385.55 g (0.85 libras)
Transferencia de datosUSB, Flash Card (SD)
MostrarLCD gigante

10. Garantía y soporte

This product is covered by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official Dickson website. For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact Dickson customer service through their official channels.

Dickson Official Websitio: www.dicksonlogger.com