ARROW AK-22123-CDC Lumen CVC for High Volume Infusions-LOGO

ARROW AK-22123-CDC Lumen CVC for High Volume Infusions

ARROW AK-22123-CDC Lumen CVC for High Volume Infusions-PROD

Contenido

  • Arrowg+ard Blue® Three-Lumen Catheter: 12 Fr. (4.1 mm OD) x 16 cm
  • Spring-Wire Guide, Marked: .035″ (0.89 mm) dia. x 23-5/8″ (60 cm) (Straight Soft Tip on One End – “J” Tip on Other) with Arrow Advancer
  • Catéter: 18 Ga. X 2-1 / 2 ″ (6.35 cm) Radiopaco sobre 20 Ga. Aguja introductora RW
  • Aguja de inyección: 25 Ga. X 1 ″ (2.54 cm)
  • Aguja de relleno roma: 18 Ga. X 1-1 / 2 ″ (3.81 cm)
  • Pressure Transduction Probe
  • Introducer Needle: 18 Ga. x 2-1/2″ (6.35 cm) XTW and 5 mL Arrow® Raulerson Spring-Wire Introduction Syringe
  • Injection Needle: 22 Ga. x 1-1/2″ (3.81 cm) and 5 mL Luer-Slip Syringe
  • Jeringa: 3 mL Luer-Lock
  • Tissue Dilator: 12 Fr. (4.0 mm) x 14 cm
  • 5 ml de solución de lidocaína HCl al 1% y preparación de alcohol
  • 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®1 One-Step Solution with Hi-Lite Orange™ Tint
  • Recipiente para desechos con cierre SharpsAway® II
  • SharpsAway® Disposal Cup
  • Cortina: 41 ″ x 55 ″ con fenestración de 4 ″
  • Portaagujas
  • Bisturí de seguridad: #11
  • Almohadilla de gasa: 2 ″ x 2 ″ (5 cm x 5 cm)
  • Almohadilla de gasa: 4 ″ x 4 ″ (10 cm x 10 cm)
  • Sutura: 3-0 Seda con Aguja Curva

1A registered trademark of CareFusion or one of its subsidiaries.

Solo con receta
Aviso: Read all package insert warnings, precautions, and instructions prior to use. Failure to do so may result in severe patient injury or death. California Prop. 65
⚠ ADVERTENCIA: Cáncer y Daño Reproductivo.
www.P65Warnings.ca.gov
Not made with natural rubber latex. Store between 20 – 25°C (68 – 77°F). Sterilized using ethylene oxide unless otherwise indicated in the contents list. Fluid path components are non-pyrogenic.
Contraindicaciones: The Arrowg+ard Blue antimicrobial catheter is contraindicated for patients with known hypersensitivity to chlorhexidine, silver sulfadiazine and/or sulfa drugs. ARROW AK-22123-CDC Lumen CVC for High Volume Infusions-FIG21

Priming volumes are approximate and are done without accessories. † Flow rate values are approximate and are determined using deionized water at 100 cm head height. Arrow International LLC Subsidiary of Teleflex Incorporated 3015 Carrington Mill Blvd. Morrisville, NC 27560 USA