EPH CONTROLS R37-RF 3 Zone RF Programmer Instruction Manual

EPH CONTROLS R37-RF 3 Zone RF Programmer Instruction

CAUTION

Installation and connection should only be carried out by a qualifiedperson and in accordance with national wiring regulations.

  • Before commencing any work on the electrical connections, you must first disconnect the programmer from the mains. None of the 230V connections must be live until the installation has been completed and the housing is closed. Only qualified electricians or authorised service staff are permitted to open the programmer. Disconnect from mains supply in the event of any damage to any buttons.
  • There are parts that carry mains voltage behind the cover. The programmer must not be left unsupervised when open. (Prevent non specialists and especially children from gaining access to it.)
  • I f the programmer is used in a way not specified by the manufacturer, its safety may be impaired.
  • Ensure that this wireless enabled programmer is installed 1 metre from any metalic object, television, radio or wireless internet transmitter.
  • Prior to setting the programmer, it is neccessary to complete all required settings described in this section.
  • Never remove this product from the electrical baseplate. Do not use sharp tools to push any button.

INSTALLATION

This programmer can be mounted in the following ways:

  1. Directly wall mounted
  2. Mounted to a recessed conduit box

Contents

  1. Factory default settings
  2. Specifications & wiring
  3. Setting the date & time
  4. Frost protection
  5. Master reset

Factory default settings

  • Contacts: 230 Volt
  • Program: 5/2D
  • Backlight: On
  • Keypad: Unlocked
  • Frost Protection: Off
  • Clock type: 24 Hr Clock
  • Day-Light Saving

Specifications & wiring

  • Power Supply: 230 Vac
  • Ambient Temp: 0~35°C
  • Contact Rating: 250 Vac 3A(1A)
    Program Memory
  • backup: 1 year
  • Battery: 3Vdc Lithium LIR 2032
  • Backlight: Blue
  • IP rating: IP20
  • Backplate: British System Standard
  • Pollution degree 2: Resistance to voltage surge 2000V as per EN 60730
  • Automatic Action: Type 1.S
  • Software: Class A

Setting the date and time

Lower the cover on the front of the programmer.
Move the selector switch to the CLOCK SET position.

  • Press the or buttons to select the day. press OK
  • Press the or buttons to select the month. press OK
  • Press the or buttons to select the year. press OK
  • Press the or buttons to select the hour. press OK
  • Press the or buttons to select the minute. press OK
  • Press the or buttons to select 5/2D, 7D or 24H press OK

The date, time and function are now set.
Move the selector switch to the RUN position to run the program, or to the PROG SET position to change the program setting.

Frost protection function

Selectable range 5~20°C
This function is set to protect pipes against freezing or to prevent low room temperature when the programmer is programmed to be OFF or is manually OFF.

  • Frost protection can be activated by following the procedure below.
  • Move the selector switch to the RUN position.
  • Press both the and buttons for 5 seconds, to enter selection mode.
  • Press either the or buttons to to turn On or turn off frost protection.
  • Press button to confirm
  • Press either the or buttons to increase or decrease the desired frost protection setpoint. Press to select.

All zones will be switched ON in the event of room temperature falling below the frost protection setpoint.

Master reset

Lower the cover on the front of the programmer. There are four hinges holding the cover in place. Between the 3rd and 4th hinges there is a circular hole. Insert a ball point pen or similar object to master reset the programmer. After pressing the master reset button, the date and time will now need to be reprogrammed.

EPH Controls Ireland
technical@ephcontrols.com
www.ephcontrols.com

EPH Controls UK
technical@ephcontrols.com
www.ephcontrols.co.uk

Documents / Resources

EPH CONTROLS R37-RF 3 Zone RF Programmer [pdf] Instruction Manual
R37-RF 3 Zone RF Programmer, R37-RF, 3 Zone RF Programmer, Zone RF Programmer, RF Programmer, Programmer

Recent Posts

SBS TEJZSPEAKWITCH20BTK WITCHER 20 Wireless Speaker User Manual

TEJZSPEAKWITCH20BTK WITCHER 20 Wireless Speaker TEJZSPEAKWITCH20BTK WITCHER 20 Wireless Speaker AUX input (7) Type-C port…

1 second ago

SIEMENS EC6A.H.90 Built-In Gas Hob Instruction Manual

EC6A.H.90 Built-In Gas Hob Built-in gas hob EC6A.H.90., EC6A.P.90., EC7A.QB90, EC7A.RB90., EC7A.S.90., EC9A.RB90., EC9A.TB90, EC9A.S.90…

33 seconds ago

BOSCH PSB3A.B20 Built-In Gas Hob User Manual

PSB3A.B20 Built-In Gas Hob boMsgecywRnthBefeeo-rwhegslcecoidsohbmetmevneeinocree.wecfyiooaotnsnum:dr / Built-in gas hob PSB3A.B20. [en] Information for Use PSB3A.B20.…

36 seconds ago

NANO N2KB Fire Detection And Extinguishing Control System User Manual

N2KB Fire Detection And Extinguishing Control System Concise User Manual NANO FIRE DETECTION AND EXTINGUISHING…

39 seconds ago

TROY-BILT Mustang Z42E XP 42 Inch Battery-Powered Brushless Zero-Turn Mower User Manual

Mustang Z42E XP 42 Inch Battery-Powered Brushless Zero-Turn Mower Models Warranty Mustang Z42E XP This…

17 mins ago

FORTINET 40F and 60F Series Fortigate FortiWiFi 60F Secure SD-WAN Appliance User Guide

40F and 60F Series Fortigate FortiWiFi 60F Secure SD-WAN Appliance QuickStart Guide FortiGate/FortiWiFi 40F &…

25 mins ago