EPEVER PWM-VS1024AU AU Series Solar Charge Controller

※ Thank you for selecting ViewStar AU series solar charge controller. Please read this manual carefully before using the product.

Overview

Thank you for selecting the ViewStar AU series common positive solar charge controller. The VS-AU controller is a PWM charge controller with built in LCD display that adopts the most advanced digital technique. The multiple load control modes enable it can be widely used on solar home system, traffic signal, solar street light, solar garden lamp, etc. The features are listed below:

  • Adopt high quality components of ST,IR and Infineon, make sure product using lifespan
  • Terminals have UL and VDE certification, the product is more safer and more reliable
  • Controller can work continuously at full load within the environmen temperature range from -25 to 55 ℃
  • 3-Stage intelligent PWM charging:Bulk, Boost/Equalize, Float
  • Support 3 charging options: Sealed, Gel, and Flooded
  • LCD display design, dynamically displaying device’s operating data and working condition
  • Double USB design, the power supply charge for electronic equipment
  • With humanized button settings, operation will be more comfortable and convenient
  • Multiple load control modes
  • Energy statistics function
  • Battery temperature compensation function
  • Extensive Electronic protection

Product Features

LCDBattery Terminals
MENU ButtonLoad Terminals
RTS PortSET Button
PV TerminalsUSB Output Ports※

※ USB output ports provide the power supply of 5VDC/2.4A and have the short circuit protection

Optional Accessory:
Name: Remote Temperature Sensor
Model: RTS300R47K3.81A
Acquisition of battery temperature for undertaking temperature compensation of control parameters, the standard length of the cable is 3m (length can be customized). The RTS300R47K3.81A connects to the port
③ on the controller.

NOTE: Unplug the RTS, the temperature of battery will be set to a fixed value 25ºC.

Wiring

  1. Connect components to the charge controller in the sequence as shown above and pay much attention to the “+” and “-”. Please don’t insert the fuse or turn on the breaker during the installation. When disconnecting the system, the order will be reserved.
  2. After power on the controller, check the LCD on. Otherwise please refer to chapter 6.Always connect the battery first, in order to allow the controller to recognize the system voltage.
  3. The battery fuse should be installed as close to battery as possible. The suggested distance is within 150mm.
  4. The VS AU series is a positive ground controller. Any positive connection of solar, load or battery can be earth grounded as required.
NOTE: Please connect the inverter or other load that it has the large start current to the battery rather than to the controller, if the inverter or other load is necessary.

Operation

Button Function
ButtonFunction
MENU button
  • Browse interface
  • Setting parameter
SET button
  • Load ON/OFF
  • Clear error
  • Enter into Set Mode
  • Save data
LCD Display

  • Status Description
    ItemIconStatus
    PV arrayDay
    Night
    No charging
    Charging
    PV Voltage, Current ,Power
    BatteryBattery capacity, In Charging
    Battery voltage. current, temperature
    Battery type
    LoadLoad ON
    Load OFF
    Load Voltage, Current, Load mode
  • Browse interface

NOTE:

  1. When no operation, the interface will be automatic cycle, but the follow two interfaces not be display.
    PWM-VS1024AU AU Series Solar Charge Controller Display Interface
  2. Accumulative power zero clearing: Under PV power interface, press SET button andhold on 5s then the value blink, press SET button again to clear the value.
  3. Setting temperature unit: Under battery temperature interface, press SET button and hold on 5s to switch.
  • Fault Indication
    StatusIconDescription
    Battery over dischargedBattery level shows empty, battery frame blink, fault icon blink
    Battery over voltageBattery level shows full, battery frame blink, fault icon blink
    Battery OverheatingBattery level shows current value, battery frame blink, fault icon blink
    Load failureLoad overload ①,Load short circuit

① When load current reaches1.02-1.05 times 1.05-1.25 times, 1.25-1.35 times and 1.35-1.5 times more than nominal value, controller will automatically turn off loads in 50s, 30s,10s and 2s respectively

Load mode setting

Operating Steps:
Under load mode setting interface, press SET button and hold on 5s till the number begin flashing, then press MENU button to set the parameter, press SET button to confirm.

Timer 1Timer 2
Light ON/OFFDisabled
Load will be on for 1 hour since sunsetLoad will be on for 1 hour before sunrise
Load will be on for 2 hours since sunsetLoad will be on for 2 hours before sunrise
Load will be on for 3~13 hours since sunsetLoad will be on for 3~13 hours before sunrise
Load will be on for 14 hours since sunsetLoad will be on for 14 hours before sunrise
Load will be on for 15 hours since sunsetLoad will be on for 15 hours before sunrise
Test modeDisabled
Manual mode (Default load ON)Disabled

NOTE: Please set Light ON/OFF, Test mode and Manual mode via Timer1. Timer2 will be disabled and display “2 n”.

Battery Type
  • Operating Steps

Under Battery Voltage interface, press SET button and hold on 5s then enter into the interface of Battery type setting. After choosing the battery type by pressing MENU button, waiting for 5s or pressing SET button again to modify successfully.

  • Battery Type

NOTE: Please refer to the battery voltage parameters table for the different battery type.

Protections

ProtectionConditionsStatus
PV Reverse PolarityWhen the battery is correct connecting, the PV can be reversed.The controller is not damage
Battery Reverse PolarityWhen the PV is not connecting, the battery can be reversed.
Battery Over VoltageThe battery voltage reaches to the OVDStop charging
Battery Over DischargeThe battery voltage reaches to the LVDStop discharging
Battery OverheatingTemperature sensor is higher than 65℃Output is OFF
Temperature sensor is less than 55℃Output is ON
Controller OverheatingTemperature sensor is higher than 85℃Output is OFF
Temperature sensor is less than 75℃Output is ON
Load Short CircuitLoad current ≥2.5 times rated current One short circuit, the output is OFF 5s; Two short circuit, the output is OFF 10s;
Three short circuit, the output is OFF 15s; Four short circuit, the output is OFF 20s;
Five short circuit, the output is OFF 25s; Six short circuit, the output is OFF
Output is OFF
Clear the fault: Restart the controller or wait for one night-day cycle (night time>3 hours).
Load OverloadLoad current ≥2.5 times rated current 1.02-1.05 times, 50s,
1.05-1.25 times, 30s
1.25-1.35 times,10s
1.35-1.5 times 2s
Output is OFF
Clear the fault: Restart the controller or wait for one night-day cycle (night time>3 hours).
Damaged RTSThe RTS is short-circuited or damagedCharging or discharging at 25℃

Troubleshooting

FaultsPossible reasonsTroubleshooting
The LCD is off  during daytime when sunshine falls on PV modules properlyP array disconnectionConfirm that PV wire connections are correct and tight
Wire connection is correct, LCD not display
  1. Battery voltage is lower than 9V
  2. PV voltage is less than battery voltage
  1. Please check the voltage of battery. At least 9V voltage to activate the controller
  2. Check the PV input voltage which should be higher than battery’s
Interface blinkBattery over voltageCheck if the battery voltage is higher than OVD point (over voltage disconnect voltage), and disconnect the PV.
Interface blinkBattery over dischargedWhen the battery voltage is restored to or above LVR point (low voltage reconnect voltage), the load will recover
Interface blinkBattery OverheatingThe controller will automatically turn the system off. But while the temperature decline to be below 50 ºC, the controller will resume.
Interface blinkOver load or Short circuitPlease reduce the number of electric equipments or check carefully loads connection.

Disclaimer

This warranty does not apply under the following conditions:

  1. Damage from improper use or use in an unsuitable environment.
  2. PV or load current, voltage or power exceeding the rated value of controller.
  3. The controller is working temperature exceed the limit working environment temperature.
  4. User disassembly or attempted repair the controller without permission.
  5. The controller is damaged due to natural elements such as lighting.
  6. The controller is damaged during transportation and shipment.

Technical Specifications

ItemVS1024AUVS2024AUVS3024AUVS3048AUVS4524AUVS4548AUVS6024AUVS6048AU
Nominal system voltage12/24VDC Auto12/24/36/48VDC Auto12/24VDC

Auto

12/24/36/48VDC

Auto

12/24VDC

Auto

12/24/36/48VDC

Auto

Battery input voltage range9V~32V9V~64V9V~32V9V~64V9V~32V9V~64V
Rated charge/discharge current10A@55℃20A@55℃30A@55℃45A@55℃60A@55℃
Max. PV open circuit voltage50V96V50V96V50V96V
Battery typeSealed(Default) / Gel / Flooded
Equalize Charging Voltage※Sealed:14.6V/ Gel: No/ Flooded:14.8V
Boost Charging Voltage※Sealed:14.4V/ Gel:14.2V/ Flooded:14.6V
Float Charging Voltage※Sealed/Gel/Flooded:13.8V
Low Voltage Reconnect Voltage※Sealed/Gel/Flooded:12.6V
Low Voltage Disconnect Voltage※Sealed/Gel/Flooded:11.1V
Self-consumption≤9.2mA/12V;≤11.7mA/24V; ≤14.5mA/36V;≤17mA/48V
Temperature compensation coefficient-3mV/℃/2V(25℃)
Charge circuit voltage drop≤0.29V
Discharge circuit voltage drop≤0.16V
LCD temperature range-20℃~+70℃
Working environment temperature-25℃~+55℃(Product can work continuously at full load)
Relative humidity≤95%, N.C.
EnclosureIP30
GroundingCommon Positive
USB output5VDC/2.4A(Total)
Overall dimension142x85x41.5mm160×94.9×49.3mm181×100.9×59.8mm194×118.4×63.8mm214×128.7×72.2mm
Mounting dimension130x60mm148x70mm172x80mm185x90mm205x100mm
Mounting hole sizeΦ4.5mmΦ5mmΦ5mmΦ5mm
Terminals4mm2/12AWG10mm2/8AWG16mm2/6AWG16mm2/6AWG25mm2/4AWG
Net weight0.22kg0.35kg0.55kg0.58kg0.76kg0.88kg1.02kg1.04kg
Above the parameters are in 12V system at 25, twice in 24Vsystem, triple in 36V system and quadruple in 48V system.

Any changes without prior notice! Version number:V1.2

BEIJING EPSOLAR TECHNOLOGY CO., LTD. Tel: +86-10-82894112 / 82894962 Website:www.epsolarpv.com / www.epever.com

Documents / Resources

EPEVER PWM-VS1024AU AU Series Solar Charge Controller [pdf] User Manual
PWM-VS1024AU AU Series Solar Charge Controller, PWM-VS1024AU, AU Series Solar Charge Controller, Solar Charge Controller, Charge Controller, Controller

References

Leave a comment

Your email address will not be published. Required fields are marked *