SD-9563-KSVQ 6 Inch Round IR Wave to Open Sensor
“
Specifications
- Operating voltage: 12~24 VDC
- Relay type: SPDT dry contact, 1.2A@24VDC
- Response time: 23mA / 29mA
- LEDs: Standby Triggered
- Output duration: 0.5~30 seconds
- Range: 2~7 (5~18 cm)
- Destructive attack level: Not specified
- Line security: Not specified
- Endurance level: Not specified
- Standby power: Not specified
- IP Rating: Not specified
- Operating temperature: Not specified
- Weight: Not specified
Overview
Sensor layout:
Side Sensor range adjustment Output duration adjustment
LED Control jumper 5-Pin connector SPDT Mechanical Override*
23/4 (70mm)
Installation
- Run four wires through the wall to a corresponding back box.
Power must be provided by a low-voltage power-limited/Class 2 power
supply and low-voltage field wiring not to exceed 98.5ft. - Connect the 4 wires from the back box to the sensor according
to the Wiring Diagram. - For weatherproof installation, use a waterproof back box and
apply a bead of silicone sealant around the rim of the back box and
faceplate edge. Apply a small amount of sealant below each screw
head. - Screw the plate into the back box, taking care not to crimp the
wires and ensuring a good seal. - Remove clear protective film from the sensor before use.
Changing the LED Color
The LED factory default color setting is red during standby,
turning to green when triggered. To reverse, move the jumper from
the center and right posts to the left and center posts.
Adjusting the Sensor Range and Output Duration
The sensor range and output duration can be adjusted using the
two potentiometers on the back of the sensor.
Sensor range adjustment:
- The sensor range can be adjusted from 2~7 (5~18 cm). Factory
default is 7 (18cm).
Output duration adjustment:
- Output duration can be adjusted from 0.5~30 seconds (default,
0.5 seconds) or toggle. Turn clockwise to the maximum position for
toggle.
FAQ
Q: Can the sensor be triggered by direct light sources?
A: Yes, due to the nature of IR technology, an IR sensor can be
triggered by direct light sources such as sunlight or reflected
light from shiny objects. It may be necessary to shield the sensor
in such locations.
Q: What is the maximum output duration of the sensor?
A: The maximum output duration of the sensor is 30 seconds.
“`
6″ Round IR WavetoOpen Sensor with Manual Override
SD-9563-KSVQ
Installation Manual
The ENFORCER 6″ Round IR Wave-to-Open Sensor with Manual Override is a full-featured exit plate using IR technology to allow egress from a protected area or activate a device with the simple wave of a hand. Since no touch is required, this sensor is suitable for use in hospitals, clinics, labs, cleanrooms (to reduce the risk of contamination), schools, factories, or offices. Adjustable sensor range up to 7″ (18cm) 1.2A relay, adjustable trigger duration 0.5~30 seconds or toggle LED illuminated sensor for easy identification Selectable LED color turns from red to green (or green to red) when the sensor is activated 6″ Round stainless steel plate for mounting to a single-gang back box IP65 Weatherproof for outdoor use Power must be provided by low-voltage power-limited/Class 2 power supply Use only low-voltage field wiring and do not exceed 98.5 ft (30m)
6″ Round IR WavetoOpen Sensor with Manual Override
Parts List
1x 6″ Round IR Wave-to-Open Sensor
2x Faceplate screws
1x Wiring harness
1x Manual
Specifications
Operating voltage
Current draw (max. ±10%)
Standby red (12/24 VDC) Triggered green (12/24 VDC) Standby green (12/24 VDC) Triggered red (12/24 VDC)
Relay type
Response time
LEDs
Standby Triggered
Output duration
Range
Destructive attack level
Line security
Endurance level
Standby power
IP Rating
Operating temperature
Weight
*Color function reversible When properly installed
12~24 VDC 18mA / 23mA 23mA / 29mA 14mA / 18mA 28mA / 35mA SPDT dry contact, 1.2A@24VDC
10ms Red* Green* 0.5~30 s, toggle 2″~7″ (5~18 cm) Level I Level I Level IV Level I Weatherproof, IP65 -4°~131° F (-20°~55° C) 7.3-oz (208g)
Overview
Sensor layout
Side
ø6″ (ø152mm)
Sensor range adjustment Output duration adjustment
LED Control jumper 5-Pin connector
SPDT Mechanical Override*
23/4″ (70mm)
INSTALLATION NOTES:
This product must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electrical Code CSA C22.1.
Due to the nature of IR technology, an IR sensor can be triggered by a direct light source such as sunlight, reflected light from a shiny object, or other direct light. Therefore, in some locations it may be necessary to install a hood or other barrier to shield the sensor from direct light sources.
2
SECO-LARM U.S.A., Inc.
6″ Round IR WavetoOpen Sensor with Manual Override
Installation
1. Run four wires through the wall to a
Fig. 1 Wiring Diagram
corresponding back box. Power must be
provided by a low-voltage power-
limited/Class 2 power supply and lowvoltage field wiring not to exceed 98.5ft
Red Wire: +12~24 VDC
(30m).
Brown Wire: Ground (-)
2. Connect the 4 wires from the back box to the sensor according to the Wiring Diagram
Blue Wire: COM
(see Fig. 1).
Purple Wire: N.O.
3. For weatherproof installation, use a waterproof back box and apply a bead of
Green Wire: N.C.
silicone sealant (not included) around the
rim of the back box and faceplate edge.
Apply a small amount of sealant below each screw head.
4. Screw the plate into the back box, taking care not to crimp the wires and ensuring a good seal.
5. Remove clear protective film from the sensor before use.
WARNING: Do not connect any device that will exceed 1.2A@24VDC.
Changing the LED Color The LED factory default color setting is red during standby, turning to green when triggered. To reverse, move the jumper from the center and right posts to the left and center posts (see Fig. 2.
Fig. 2
Standby: Green Trigger: Red
Standby: Red Trigger: Green
(default)
Adjusting the Sensor Range and Output Duration
The sensor range and output duration can be Fig. 3
adjusted using the two potentiometers on the back of the sensor (see Fig. 3).
Sensor range adjustment
1. The sensor range can be adjusted from 2″~7″ (5~18 cm). Factory default is 7″ (18cm).
2. Output duration can be adjusted from 0.5~30 seconds (default, 0.5 seconds) or toggle. Turn clockwise to the maximum position for toggle.
NOTE: Do not force the adjustment trimpots to turn. Only minimal force is needed
Output duration adjustment
5cm
18cm 0.5s 30s
Sensor range: 2″~7″ (5~18 cm) Default: 7″ (18cm)
Output duration: 0.5~30 seconds, toggle* Default: 0.5 seconds
*Toggle: turn clockwise to maximum position
SECO-LARM U.S.A., Inc.
3
6″ Round IR WavetoOpen Sensor with Manual Override
Sample Installation
Red wire: 12~24 VDC (+) Brown wire: Ground (-) Blue wire: COM
(+) () N.C. COM N.O.
Purple: N.O.
N.O.
() Electric (+)
(+) ()
Lock
OR Green: N.C.
N.C.
12~24 VDC Power Supply
COM
NC
NO
Manual Override Button
Override button is pre-wired at the factory. No further wiring is necessary.
Troubleshooting
Sensor triggers unexpectedly
Ensure that no strong direct or reflected light source is reaching the sensor. Ensure that sensor is sheltered from direct sunlight.
Sensor remains triggered
Sensor will not trigger
Check that nothing is remaining in range of the sensor including a cone of 60º from the centerline.
Reduce the IR range of the sensor. Ensure that the sensor’s output duration potentiometer is not turned to maximum Check that the power voltage is within the sensor’s specifications.
Increase the IR range of the sensor. Check that the power voltage is within the sensor’s specifications.
Care and Cleaning
The sensor requires special care to ensure reliability and a long operating life.
1. Use a soft, clean, preferably microfiber cloth for cleaning. Use the mildest type of cleaner available. 2. When cleaning, spray the cleaning solution onto the cleaning cloth instead of the unit. 3. Be sure to wipe off any excess liquid from the sensor. Wet spots may affect the sensor’s performance.
IMPORTANT WARNING: For a weather-resistant installation, ensure that the unit is installed in a waterproof back box, and that the faceplate and faceplate screws are properly sealed. Incorrect mounting may lead to exposure to rain or moisture inside which could cause a dangerous electric shock, damage the device, and void the warranty. Users and installers are responsible for ensuring that this product is properly installed and sealed.
IMPORTANT: Users and installers of this product are responsible for ensuring that the installation and configuration of this product complies with all national, state, and local laws and codes. SECO-LARM will not be held responsible for the use of this product in violation of any current laws or codes.
California Proposition 65 Warning: These products may contain chemicals which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.
WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for one (1) year from the date of sale to the original customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damage of any kind to the purchaser or anyone else.
NOTICE: The SECO-LARM policy is one of continual development and improvement. For that reason, SECO-LARM reserves the right to change specifications without
notice. SECO-LARM is also not responsible for misprints. All trademarks are the property of SECO-LARM U.S.A., Inc. or their respective owners. Copyright © 2025
SECO-LARM U.S.A., Inc. All rights reserved.
SECO-LARM ® U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606 Website: www.seco-larm.com Phone: 949-261-2999 | 800-662-0800 Email: sales@seco-larm.com
PITSW1 Order Part# 763-195% MI_SD-9563-KSVQ_250528.docx