EMTEK - Logo

Installation & Programming Guide
Modern Style & Classic Style Electronic Keypad Lever Locksets

EMTEK Modern Style and Classic Style Electronic Keypad Lever Locksets - Cover

What’s in the Box

ITEM NO.DESCRIPTIONQTY.
1Key2
2Outside Trim Plate Assembly1
3Latch for 23/8” or 23/4” Backset1
4Inside Trim Plate Assembly1
4aInside Chassis1
4bInside Trim Plate1
4c#8-32 x 3/8″ Flat Head Machine Screw2
4d 9V Alkaline Battery1
5#8-32 x 11/2″ Flat Head Machine Screw2
6#8 x 3/4″ Wood Screw4
7Strike Plate1
8Plastic Extender1

Preparation

Confirm Handing
HANDING OF DOOR IS ALWAYS DETERMINED FROM THE OUTSIDE

How to Install

1. Install Latch

Fasten Latch using two #8 x 3/4” Wood Screws (item #6).
EMTEK Modern Style and Classic Style Electronic Keypad Lever Locksets - How to Install 1

Remove Screws from Inside Trim Plate
Use a Phillips head screwdriver to remove screws (item #4c) shown below and detach Inside Trim Plate from the Inside Chassis.

medisana BU 584 Connect Upper Arm Blood Pressure Monitor - icon 8 Remove inside chassis from trim plate before installing the outside trim. Thumbturn must be in neutral position.

EMTEK Modern Style and Classic Style Electronic Keypad Lever Locksets - How to Install 2

Install Outside Trim Plate Assembly

STEP1 While holding Outside Trim
Plate Assembly, Press the Plastic Extender (A) into end of Spindle Shaft (B). The Shaft is properly aligned when the marking ‘TOP’ can be seen from an overhead view.

EMTEK Modern Style and Classic Style Electronic Keypad Lever Locksets - How to Install 3

STEP 2 Position the Outside Trim Plate Assembly through the bore hole.

medisana BU 584 Connect Upper Arm Blood Pressure Monitor - icon 8 Once positioned, outside trim plate assembly requires support.

EMTEK Modern Style and Classic Style Electronic Keypad Lever Locksets - How to Install 5

STEP 3 With the Outside Trim Plate Assembly flush to the door, REMOVE the Plastic Extender.

Install Inside Chassis

STEP 1
Confirm the position of Cam Link.
EMTEK Modern Style and Classic Style Electronic Keypad Lever Locksets - How to Install 6medisana BU 584 Connect Upper Arm Blood Pressure Monitor - icon 8 Cam link must remain in the correct position during installation.

STEP 2
Feed the Wire Harness through Inside Chassis.

EMTEK Modern Style and Classic Style Electronic Keypad Lever Locksets - How to Install 6STEP 3
Fasten Inside Chassis using two #8-32 x 11/2”
Flat Head Machine Screw (item #5).

STEP 4
Connect Wire Harness (A) and tuck Connectors as shown (B).

EMTEK Modern Style and Classic Style Electronic Keypad Lever Locksets - How to Install 7STEP 5
Install Battery.

EMTEK Modern Style and Classic Style Electronic Keypad Lever Locksets - How to Install 8Install Inside Trim Plate
Fasten Inside Trim Plate using two#8-32 x 3/8”
Flat Head Machine Screws (item #4c).

*Neutral position is required for installation and removal of the Inside Trim Plate Assembly.
(Does not apply to Keypad Storeroom/Gate product)

How to Use

Your Lock is Ready to Use
Your Emtek lock is shipped with two 4-digit user codes and a 6-digit programming code.
These codes are randomly generated at the factory.
(Turn to next page for Programming Instructions.)

To Unlock:

  1. Enter 4-digit user codes.
    (See sticker located on the inside trim plate or back cover page).
  2. Turn Handle.
    EMTEK Modern Style and Classic Style Electronic Keypad Lever Locksets - How to Use 1

Passage Feature
(Does not apply to Keypad Storeroom/Gate product)
Activate by turning the inside thumbturn to the unlocked position. This will engage the outside lever so a code is not required to enter.

To Lock

  1. Rotate Thumbturn from inside.

EMTEK Modern Style and Classic Style Electronic Keypad Lever Locksets - How to Use 2

How to Program

Programming Your Lock
In order to perform each of the following six functions, the lock must first be placed in Programming Mode:

  1. Press and hold EMTEK button for 3 seconds
  2. Yellow LED flashes, then remains solid*
  3. Enter Programming Code
  4. Green LED flashes, then 2 beeps
  5. Yellow LED remains solid (awaiting button press; see following table)
If You Wish ToPress ButtonActionsIndicators
Change Programming Code (6 digits)1Enter New
Programming Code
(6 digits)
Re-Enter New
Programming Code
(6 digits)
•1 Green LED flash
•1 beep
•1 Green LED flash
•1 beep
•2 Green LED flashes
•2 beeps
Add User Code (4 digits) (Store up to 20 User Codes)2Enter New User
Code (4 digits)
Re-Enter New User
Code (4 digits)
•1 Green LED flash
•1 beep
•1 Green LED flash
•1 beep
•2 Green LED flashes
•2 beeps
Delete User Code3Enter User Code to be DeletedRe-Enter User Code to be Deleted•1 Green LED flash
•1 beep
•1 Green LED flash
•1 beep
•2 Green LED flashes
•2 beeps
**Enable/Disable All User Codes4Entering ‘ disables all Users
(enables all if disabled)
•2 Green LED flashes
•2 beeps
Delete All User Codes5Re-Enter Programming Code•1 Green LED flash
•1 beep
•2 Green LED flashes
•2 beeps
Turn Beeper On/Off6Entering ‘6’ turns Of F (or ON)•1 Green LED flash
•1 beep
•2 Green LED flashes
•2 beeps

*If no input within 10 seconds, Yellow LED goes out, Red LED flashes and lock exits Programming Mode.
**Also referred to as “vacation mode”. This command temporarily disables all user codes (metal key override will still work).

Keypad Operation – Beeper & LED Indicators

FunctionIndicators
Valid Code•  1 short beep, EMTEK button flashes Green.
Invalid Code/Access Denied*• 1 Red LED flash
•  2 short beeps
Lock-Out Mode Error• 2 short beeps
• 1 short beep per second for duration
Access Accepted• 1 short beep
• 1 Green LED flash
Low Battery• 4 Red LED flashes
• 4 short beeps
Blackout Battery**• 1 long Red LED flash
• 4 long beeps
Button Press Accepted• 1 Yellow LED flash
• 1 Short Beep
Outside Thumb Turn Enabled• 2 Green LED flashes

* If 3 consecutive incorrect codes are entered, the lock emits 4 short beeps and a flashing Red EMTEK button. The lock will not accept additional input for 20 seconds (20 beeps). When the next valid code is entered the lock will beep quickly 3 times to alert of the incorrect codes.
** Battery voltage has dropped too low; keypad will be disabled but metal key override will still work.

Restoring the Lock to Factory Default Setting

This procedure clears the lock of all users and restores the Programming Code and 2 User Codes shipped with the lock.

  • Remove power (disconnect 9V battery) from Lock.
  • Press and hold EMTEK button.
  • While continuing to hold EMTEK button, restore power (reconnect 9V battery).
  • Continue to hold EMTEK button for 3 seconds.
  • 1 Green LED flash and 2 short beeps followed by 1 Green LED Flash and 2 short beeps indicates the lock has been successfully restored

U.S. patents: 8,176,761 8,141,400
Canadian patents: 2,698,041 2,789,278 2,789,280

EMTEK - Logo

Emtek Products
Tel: 800-356-2741626-961-0413
Fax: 800-577-5771626-336-2812
emtek.com

Copyright © Emtek Products, ASSA ABLOY Residential Group Inc. DBA Emtek Products, 2021
Reproduction in whole or in part without the express written permission of Emtek Products is prohibited.
IN8-KEYPADLL

Documents / Resources

EMTEK Modern Style and Classic Style Electronic Keypad Lever Locksets [pdf] Installation Guide
Modern Style and Classic Style Electronic Keypad Lever Locksets, Modern Style Electronic Keypad Lever Locksets, Classic Style Electronic Keypad Lever Locksets, Electronic Keypad Lever Locksets, Electronic Lever Locksets, Keypad Lever Locksets, Lever Locksets, Keypad Locksets, Electronic Locksets, Locksets

References

Leave a comment

Your email address will not be published. Required fields are marked *