ELRO CBFS58R 433MHz Smoke Alarm Device Instruction Manual INTENDED USE: FIRE SAFETY ESSENTIAL CHARACTERISTICS: PASSED Nominal Avion condones…
Ground floor
First floor
Attic
INTENDED USE: FIRE SAFETY
ESSENTIAL CHARACTERISTICS: PASSED
Follow instructions to ensure proper installaon. Intended use: Fire detection and fire warning for household or similar residenal applications. Local regulations shall be consulted.
Activate
Test not okay, replace alarm
5a
Press for approximately 15 seconds un l the bu Aon lights up completely. The 30 seconds of pairing mode starts. As long as the led is ON pairing mode is ac ve.
Follow process according alarm fB or adding for more smoke alarms.
5b
IMPORTANT – Ater connecting waits 20 minutes before testing.
Rooms
Low battery alert? Replace battery and test! (see 2 and 3). Mute warning for 8 hours: press the test button.
ALARM PATTERN – ALARMBILDUNG – ALARM PATROON – PATTERN D’ALARME Smoke – Rauch – Rook – Fumée
Bi 0,5s – Pause 0,5s – Bi 0,5s Pause 0,5s – Bi 0,5s Pause 1,5s + Led
ALARM PATTERN – ALARMBILDUNG – ALARM PATROON – PATTERN D’ALARME Heat – Hi e – Hitze – Chaleur
Bi 0,2s – Pause 0,1s + Led
ALARM PATTERN – ALARMBILDUNG – ALARM PATROON – PATTERN D’ALARME Wireless alarm – Drahtoser Alarm – Draadloos alarm – Alarme sans fil
Bi – Bi 0,2s – Pause 1,2s + Led
LED signal (flash) | Acous c signal (Bip) | Descrip on mode | |
Normal | 1 x per 40 seconds | None | Device is functioning properly |
Test | 1 x per second (3 x), pause of 1,5 seconds | 1 x per second (3 x), pause of 1,5 seconds | Device is being tested |
Alarm | 1 x per second (3 x), pause of 1,5 seconds | 1 x per seconds (3 x), pause of 1,5 seconds | Device has detected smoke |
Low battery | 1 x per 40 seconds (simultaneously with beep) | 1 x per 40 seconds (simultaneously with flash) | Battery is running low |
Fault warning | None | 1 x per 40 seconds | Device is not functioning properly |
Symbols:
Read the manual before use and store it in a safe place for future use and maintenance. Download Declara on of Performance (DoP) at www.elro.eu
Warnings:
Troubleshooting: False alarm is one caused by dust or steam. In case of doubt: Leave the building and take ac on! Additional mounting instructions: Corridor max width 3m: Max 15m between 2 alarms. Max. 7,5m to front side and alarms at edges/crossings of corridors. Galleries: Length and width >2m and >16m², additional alarms below gallery. Par al roof slopes: Flat ceiling ≤1m wide, consider as roof slope. Flat ceiling >1m wide, consider as flat ceiling.
0905
DoP: CBFS58R-01 21 CBFS58R
Manufacturer
Siterwell Electronics CO., Limited
No.666 Qingfeng Road, Jiangbei District, Ningbo, Zhejiang Province, China 315034
Importer:
ELRO Europe | www.elro.eu Postbus 9607 – Box E800
1006 GC Amsterdam The Netherlands
ELRO CBFS58R Smoke Alarm Device [pdf] Instruction Manual CBFS58R Smoke Alarm Device, CBFS58R, Smoke Alarm Device, Alarm Device, Device |
TKA8013GB Styline Filter Coffee Machine bMogsyenRBctwehfeowre-sgehlceidcoshobemtnevmeeinorce.ewcyefioootaumsnnr:/d Styline Filter coffee machine TKA80..GB [en] Instruction manual Filter…
4710562754001 Aero Bronze 750W Power Supply
XEVA130 One Charging Station Circular Pedestral a notice d'installation - p. 2 XEVA130 Pied rond…
XC5907 13 in 1 Multifunction USB Type-C Power Hub
31463M VIVALDO Hanging Lamp OFF A INSTRUCTIONS INSTRUCCIONES 31463M / 31467M - VIVALDO SAFETY PRECAUTIONS:…
VA1655 Portable 16 Inch Full HD Monitor VA1655 Display Quick Start Guide Guide de démarrage…