Thank you for purchasing the ECHANFIT CRW4106/4106B Magnetic Rowing Machine. Please read this user manual carefully and keep it for future reference. If you need any assistance, please contact our support team with your product model number and Amazon order number.

Package Contents

⚫ Magnetic Rowing Machine CRW4106/4106B
⚫ User Manual
⚫ Toolkits

Product Diagram

ECHANFIT Magnetic Rowing Machine- Product Diagram

IMPORTANT! Please retain the user’s manual for maintenance and adjustment instructions.  Your satisfaction is very important to us, please do not return until you have contacted us.

IMPORTANT SAFETY INFORMATION

Thank you for choosing ECHANFIT magnetic rowing machine CRW4106/4106B.
Warning: To ensure your safety and health, please use this rowing machine correctly. It is important to read this entire manual before assembling and using the rowing machine.  safe and effective use can only be achieved if the rowing machine is assembled, maintained, and used properly. It is your responsibility to ensure that all users of the rowing machine are informed of all warnings and precautions.

  1. Before starting the exercise, you should consult with your doctor to determine if your health and physical condition are adequate for using this product together. Because the bad condition of the body can bring hidden trouble to your health and safety or hinder you to use this rowing machine correctly.
  2. If you are taking medication that affects your heart rate or blood pressure, your doctor’s advice is extremely important.
  3.  Always pay attention to the adverse reactions of the body. Improper and excessive use can damage your body. If you notice any of the following symptoms, stop exercising immediately: Chest pain and chest tightness, abnormal heartbeat, shortness of breath, lightheadedness, dizzy or nauseous. If any of these symptoms occur during exercise, be sure to consult your doctor before continuing exercise.
  4.  Keep children and pets away from rowing machines. This rowing machine is only suitable for adults!
  5. Please place the rowing machine on a firm, flat horizontal surface with soft materials to protect your ground and carpets. Keep at least 0.6m of open space around the rowing machine!
  6. Please make sure all screws and nuts are locked before using the rowing machine.
  7. Use the rowing machine correctly according to the rowing machine label. When parts are found to be defective during assembly or inspection of the appliance, or when you hear abnormal sound from the device, please stop using it immediately. Never continue to use the rowing machine until the problem is solved.
  8. Please wear suitable clothing when you exercise. Avoid loose clothing during exercise, such clothes are easy to hang on or limit movement.
  9. This rowing machine is only for indoor use, max user weight of 264LB.
  10.  Please be careful not to sprain your back when moving or uplift this rowing machine.
  11.  This rowing machine is not suitable for medical rehabilitation.
  12.  Please properly keep the instruction manual and assembly tools for emergency use.

EXPLODED DIAGRAM

ECHANFIT Magnetic Rowing Machine- EXPLODED DIAGRAM

PARTS LIST

No.DescriptionQtyNo.DescriptionQty
1Main frame135Flat washer 52
2Rear foot tube frame136Flat washer 823
3Slide tube frame137Flat washer 101
4Foot pedal tube assembly138Left protective cover1
5Computer bracket139Right protective cover1
6Tension tube140Decorative cover2
7Seat cushion limiting plate241Armrest fixi-ig pad1
8Seat cushion mounting plate242Foot pedal2
9Front foot tube143Belt PJ660260J1
10Magnetic wheel144Ribbon pulley 045’351
11Deep groove ball bearing 608-2RS445Foam L=210mm2
12Deep groove ball bearing 6000-2RS246Foot pedal adjusting belt2
13Pull rod447resistance knob (assembly)1
14Pull rod limiting plate448Pullback device1
15Men wrench149Seat cushion wheel2
16Wrench with screw driver150Seat cushion1
17Lock nut M8551Left front cover1
18Lock nut M10152Eccentric foot cover2
19Nut MB453Circular tube plug2
20Nut M10’1.0454Limit sleeve1
21Nut M10’1.0455Cushion pad4
22Bolt M8’125356Non-slip mat1
23Isolation nylon pad 023’010.5’2257Computer back cover1
24Bolt M8’65458Computer up cover1
25Bolt M10’55159Dry battery2
26Bolt M8’201160Bottom wire L=500m2
27Bolt M8’40261Induction bar clamp1
28Screw ST4.2’12862Roller spacing4
29Suew ST4.2’9.5163Right front cover1
30Bolt M5’10364Seat cushion wheel2
31Bolt ST42’13865Bolt M6’502
32Screw ST4.2’91266Nut M62
33Bolt M6’8467Screw ST4.2’192
34Spring washer 81568Anti-slipped pad A2

HARDWARE PACKAGE

ECHANFIT Magnetic Rowing Machine- HARDWARE PACKAGE

SPARE PARTS LIST

No.DescriptionSpec.Qty.No.DescriptionSpec.Qty.
1Mainframe158Computer1
2Rearfoot tube frame124BoltM8’654
3Slide tube frame126BoltM8’207
4Foot pedal tube assembly136Flat washer813
5Computer bracket128ScrewST4.2’122
9Front foot tube134Spring washer811
42Foot pedal250Seat cushion1
15Allen wrenchS=5155Cushion pad025’182
16Wrench with screwdriverS13, 14. 15159Dry battery2
17LocknutM8227BoltM8’402
31ScrewST4.2’132

Install Tool:
#15 Allen Wrench S=5 1PC
#16 Wrench with screw driver S13、14、15 1PC

INSTALL INSTRUCTIONS

STEP 1:               ECHANFIT Magnetic Rowing Machine- INSTALL INSTRUCTIONS

Use the Allen wrench (15) lock the Front foot tube frame (9) onto the Mainframe (1) with Bolt (24), Washer (36), Spring washer (34).

STEP 2:

ECHANFIT Magnetic Rowing Machine- STEP 2

Use the Bolt (26), Flat washer (36), and Spring washer (34) to lock the Rear foot tube frame (2) on the Slide tube frame (3).

STEP 3: 

ECHANFIT Magnetic Rowing Machine- DISPLAY MANUAL

Install the Seat cushion (50) into the Slide tube frame (3).
STEP 4:

ECHANFIT Magnetic Rowing Machine- STEP 4

1. Use Bolt (26), Spring washers (34), and Flat washers (36) to lock the Slide tube frame (3) on the Mainframe (1).
2. Screw the Cushion pad (55) into the Mainframe (1).

STEP 5:

ECHANFIT Magnetic Rowing Machine- STEP 5
Lock the Foot pedal (42) to the Foot pedal tube assembly (4) with Bolt (23), Flat washer (36) and Locknut (17).
STEP 6:

ECHANFIT Magnetic Rowing Machine- STEP 6

Use Bolt (27), Spring washer (34), and Flat washer (36) to lock the Foot pedal tube assembly (4) to the Mainframe (1).

STEP 7: 

ECHANFIT Magnetic Rowing Machine- STEP 7

Insert the Sensor cable A and B into the Computer bracket (5), and then lock the screw (31) into the Computer (58).
STEP 8:

ECHANFIT Magnetic Rowing Machine- STEP 8

1. Take out the Computer up cover (58), and then put the Dry battery (59) into the Computer up cover (58) as shown in C in the figure;
2. Connect the Sensor cable as shown in figure A and B, to connect the Sensor cable A with A and B with B;
3. Insert the Computer bracket (5) into the Mainframe (1) and fix it with the Screw (28).

PEDAL ADJUSTMENT 

ECHANFIT Magnetic Rowing Machine- PEDAL ADJUSTMENTAccording to the size of feet, the pedal strap is adjustable. The specific tightness adjustment method is shown in the left figure. A direction is tense, B direction is loose.

MOVING THE MACHINE 

ECHANFIT Magnetic Rowing Machine- Frame Movement

Frame Movement:
The front foot tube frame have a transport wheel in the front, lift up the rear foot tube frame, you can move the frame to the position you want.

RESISTANCE AND FRAME BALANCE ADJUSTMENT

ECHANFIT Magnetic Rowing Machine- ADJUSTMENT

Resistance Adjustment:
Adjust the resistance knob (47) clockwise to increase the resistance and counterclockwise to reduce the resistance.
Frame Horizontal Regulation:
If the ground is uneven, the rear foot cover (52) can be adjusted according to the arrow direction A or B in the figure to make the frame level.

DISPLAY MANUAL

Button Function:
MODE: press this button to select the function.
—-Keep pressing this button for 3 seconds to clear all data, included time, times, calories burned, total count, distance and scan (all of the above).
ECHANFIT Magnetic Rowing Machine- DISPLAY MANUAL
Functional Operation:
1. SCAN: press the MODE button into scan state, the computer will automatically scatime, times, calories, the total number of times, and every scan interval is 6 seconds.
2. TIME: show the time from the computer start to the end.
3. COUNT (Times Count ): show the number of times from the computer start to the end.4. CALORIE: show the total calories from the computer start to the end.
5. TOTAL COUNT (Total Number of Times): count all times after installing the battery.
If there is any movement signal, the computer display will close automatically aft4 minutes and will wake up when there is a movement signal or any button is operated.
6. REPS/MIN (Average Speed): show the average number of movements per minute.

Scope Description: 

FunctionScanning intervalEvery 6 seconds
Time (minutes)0:00 —99:59
Times count0 —9999 times
Calories0:0 –999.9 CAL
Total number of times0– 9999 times
Battery2 piece of battery
Working temperature0 40 degree
Storage temperature-0 +60 degree degree

STORAGE AND MAINTENANCE

  1.  Keep the rowing machine in a clean and dry place.
  2.  Grasp the frame to move the rowing machine. Do not use the seat to move it. The seat
    will move and it may hurt your hand and fingers.
  3. Remove the battery before storing the machine for a long time.
  4. Clean the Seat Rail with an absorbent cloth.
  5. Always make sure all the nuts and bolts are properly tightened.
  6.  Regular inspection is required. Replace any worn or damaged parts immediately.

Warranty and Customer Support
For questions, support, or warranty claims, contact us at the address below that corresponds with your region. Please include your Amazon order number and product
model number.

Amazon US Orders: service@camelonfit.com

Please note, ECHANFIT can only provide after-sales service for products purchased directly from ECHANFIT. If you have purchased from a different seller, please contact them directly for service or warranty issues.

Model: CRW4106/4106B

XIAMEN CAMELON TECHNOLOGY CO., LTD.
https://www.amazon.com/echanfit | service@camelonfit.com