EasuPowern-ICharger-MPPT-6048-Solar-Charge-Controller-logo

EasuPowern ICharger MPPT 6048 Solar Charge Controller

EasuPowern-ICharger-MPPT-6048-Solar-Charge-Controller-product

Product Information

The ICharger MPPT 6048 is a solar charge controller designed for indoor installation only. It features a 3-stage charging mode, including constant current (MPPT), constant voltage, and floating. The controller requires copper wires and air circuit breakers for installation, which should only be done by qualified professionals. The LCD display provides information on battery type, system voltage, and charge current, among other settings.

Product Usage Instructions

Before installation, ensure that the PV modules are disconnected from the controller to avoid accidents. Follow the wire connection sequences outlined in the manual for connecting PV+ and PV- wires to the controller, and BAT+ and BAT- wires to the battery. Use only the screws provided with the controller to avoid damaging the internal PCB. Apply proper torque when pushing the screws into the casing.

Battery Type and System Voltage Settings

The LCD display provides various settings for battery type and system voltage. Use the following chart as a reference for setting the appropriate values:

Battery TypeSystem VoltEQU Charge VoltBST Charge VoltFLD Charge VoltLDV Charge VoltLRV Charge VoltBST_R Charge Volt
GELAuto14.6V14.8VDefined by GEL12.6V13.2V
SELAuto14.2V13.8V12.6V11.1V13.2V
FLDUSE Auto/12/24/36/4813.8V13.2V11.1V13.2V
LI12/24/36/4814.4V13.8V13.8V

Error Codes and Working Modes

The controller’s LCD display also provides information on error codes and working modes. Refer to the manual for a full list of error codes and their corresponding meanings. The working modesinclude:

  • Night mode, no charging (Code 3.0)
  • MPPT mode (Code 4.0)
  • Absorption mode (Code 7.0)
  • Floating mode (Code 8.0)

Remember to read all manuals before installing the controller and contact a qualified professional if you have any doubts or concerns.

Main Feature

  • 60A MPPT solar charge controller
  • MPPT technology
  • Automatic battery voltage detection for 12V/24V/36V/48V
  • 3-stage charging optimizes battery performance
  • Overcharge protection, over-temperature protection
  • Suitable for battery types such as sealed lead acid, vented gel and lithium battery, etc
  • Easy to be mounted

Warning and Caution

Be aware that only qualified professionals could install these controllers. Please read all manuals before installing them.

  1.  Keep controller away from water. Don’t use wet towel to wipe controller.
  2. Keep wiring correct, don’t reverse wiring. Please pay attention to terminal wiring sequence.
  3.  Keep controller in an environmental temperature from – 20℃~+55℃. Avoid direct sunlight.
  4.  Keep good heat dissipation.
  5.  Use the pure copper wires and connect all polarity correctly.
  6.  The load output is only for DC load less 5A current.
  7.  Please don’t set any parameters if you are not professional since the controller can work fine in default condition except lithium battery.

Air Circuit Breaker and Wires Requirement

ModelsICharger MPPT 6048
Copper wires6mm²x2PCS
Air circuit breakers100A

Wire Connection Sequences
For ICharger MPPT 6048, it’s better to connect two wires to two PV+ and another two wires to two PV-. For BAT+ and BAT-, it’s same way to connect wires.

Installation Steps

  1.  The battery voltage should be more than 12V, then the controller can boot up. Install air circuit breaker between controller and batteries. Turn o ffthe circuit breaker, then connect batteries to controller with correct polarity.
  2.  Install air circuit breaker between controller and PV modules. Turn off the circuit breaker, and ensure the PV polarity correct, then connect wires between PV modules and controller.
  3.  Turn on the air circuit breaker between controller and batteries.
  4.  Turn on the air circuit breaker between controller and PV modules.

EasuPowern-ICharger-MPPT-6048-Solar-Charge-Controller-fig-1

LCD Display Indication

EasuPowern-ICharger-MPPT-6048-Solar-Charge-Controller-fig-2

Display Introduction

EasuPowern-ICharger-MPPT-6048-Solar-Charge-Controller-fig-3

Battery Type Setting

EasuPowern-ICharger-MPPT-6048-Solar-Charge-Controller-fig-4

3. System Voltage Setting

  1.  Battery Type = USEEasuPowern-ICharger-MPPT-6048-Solar-Charge-Controller-fig-5
  2. Battery Type = LIEasuPowern-ICharger-MPPT-6048-Solar-Charge-Controller-fig-6
  3. Battery Type = SEL/GEL/FLDEasuPowern-ICharger-MPPT-6048-Solar-Charge-Controller-fig-7

Parameter Setting

  1. Battery Type = USEEasuPowern-ICharger-MPPT-6048-Solar-Charge-Controller-fig-8
  2. Battery Type = LIEasuPowern-ICharger-MPPT-6048-Solar-Charge-Controller-fig-10

Press Key Operation

EasuPowern-ICharger-MPPT-6048-Solar-Charge-Controller-fig-11Error Code

EasuPowern-ICharger-MPPT-6048-Solar-Charge-Controller-fig-13

Working Mode

CodeWorking Mode
3.0Night mode, no charging
4.0MPPT mode
7.0Absorption mode
8.0Floating mode

Manual Setting
Caution! All steps must be carried out when the PV modules are disconnected to controller.

Batteries charge voltage reference

Dimension

EasuPowern-ICharger-MPPT-6048-Solar-Charge-Controller-fig-12

Notes Please use our screws only since it may damage the internal PCB if using other screws. Please use proper torque to push the screws into casing since it may damage the internal PCB by strong torque.

Basic Parameter

ItemParameter
ModelsICharger MPPT 6048
Charging mode3-stage: constant current(MPPT), constant voltage, floating
System voltage12/24/36/48/Auto
Max PV input power720W/12V; 1440W/24V

2160W/36V; 2880W/48V

Max PV input voltage180 Voc
 

Battery voltage automatic recognition

12V system (DC8.7V-DC15.5V)

24V system (DC16V-DC31V)

36V system (DC33V-DC41V)

48V system (DC42V-DC64V)

 

Overcharging protection voltage

12V system (16V) 24V system (32V) 36V system (48V) 48V system (64V)
Limited current protection61A
Max efficiency≥98.1%
PV utilization≥99%
Auto Temperature Compensation-3mV/2V/ºC
Protection Function
Temperature protection80℃
Fan-on temperature>45℃
Fan-o fftemperature<40℃
Properties
Size (mm)214x115x50
Net weight (Kg)1.1
Gross weight (Kg)1.2
Electromagnetic compatibilityAccord to EN61000, EN55022, En55024
EnclosureIP21
Environmental temperature-20℃ ~ +55℃
Storage temperature-40℃ ~ +75℃