Quick Guide
Omniport 40 – Multifunctional Hand-Held Meter
Omniport 40 Hand Held Meter
PLEASE NOTE
Connect the probe to the Omniport before starting. Do not alternate between process probes and hand-held probes on an active device, otherwise the probes will no longer be recognised.

| No. | Function |
| 1 | 2x Probe connection |
| 2 | Status bar symbols’) |
| 3 | Input number, measured parameter and measurement unit |
| 4 | Function corresponding to left function button |
| 5 | “Left function” button |
| 6 | “OK” button: confirms selection |
| 7 | “←” button: cycles through the display modes (e.g. 2-line, stat., diagram,…) or move up one menu level |
| 8 | “F” button: favorites list |
| 9 | Status LED |
| 10 | USB-C port |
| 11 | “ON/OFF” button |
| 12 | “Down arrow” button: scrolls down a list or decreases a parameter value |
| 13 | “Menu” button |
| 14 | “Up arrow” button: scrolls up a list or increases a parameter value |
| 15 | “Right function” button |
| 16 | Function corresponding to right function key |
| 17 | Measured value |
| 18 | Battery compartment fixing screw |
| 19 | Magnet |
| 20 | Foldable stand |
| 1) Status Bar Symbols | Description |
| Battery level | |
| Ext.power supply connected | |
| Ext.power supply connected and missing or wrong batteries | |
| Hold function active | |
| Logging in progress | |
| Measurement in alarm | |
| Device is locked | |
| USB port connected to PC | |
| Real time clock | |
| Adjusted probes connected |
Find this document and further product information on our website at www.epluse.com/omniport40.

Suitable Probes and Cables
Connection cable for hand-held probe (unshielded) 2 m (6.6 ft) – HA010813
Hand-Held Probes
AVP201H – v and T Hand-Held Probe for HVAC Applications
AVP301H – v and T Hand-Held Probe up to 20 m/s (4 000 ft/min)
AVP401H – v and T Hand-Held Probe up to 2 m/s (400 ft/min)
HTP201H – RH and T Hand-Held Probe for HVAC Applications
HTP401H – RH and T Hand-Held Probe up to 100 °C (212 °F)
HTP701H – RH and T Hand-Held Probe up to 180 °C (356 °F)
MOP301H – MIO Immersion Hand-Held Probe up to 120 °C (248 °F)
MOP302H – Short MIO Hand-Held Probe up to 120 °C (248 °F)
Connection cable for process probe
1 m (3.28 ft) – HA040908
Process Probes
EE072 – RH and T Probe
EE074 – T Probe
EE671 – v Probe
EE680 – v and T Probe for Laminar Flow
EE872 – Modular Probe for CO2, RH, T and Ambient Pressure
HTP501 – RH and T Probe up to 120 °C (248 °F)
MOP301 – MIO Probe up to 120 °C (248 °F)
TDS401H – Td Probe down to -60 °C (-76 °F)
Power supply
▪ 4x AA rechargeable NiMH batteries (included in the scope of supply)
▪ 4x AA non-rechargeable batteries
▪ Extern 5 V DC via USB C (Power supply unit or PC-USB connection)
Connection to the PC
To transfer the logged data or advanced settings, the device can be connected to the PC via the USB-C connection cable (includedin the scope of supply).
Ensure that the correct USB mode is set:
USB Mode Settings
| .COM mode | Used for data aquistion. Needed for advanced setting with PCS10 Product Configuration Software. Free download from www.epluse.com/pcs10. |
| Mass storage | Enables easy download of csv files with logged data. No software is required. |
Batteries are charged via USB in both modes.
The following issues must be observed for accurate measurements.
Use the device under the climatic conditions specified in this document:
▪ Operation: -5…+50 °C (+23…+122 °F), 0…85 %RH non-condensing
▪ Storage: -25…+65 °C (-12…+149 °F) (without rechargeable battery)
Do not use the device in places with:
▪ Rapid ambient temperature variations that may cause condensation.
▪ Direct vibrations / shocks to the device.
▪ High-intensity electromagnetic fields or static electricity.
NOTICE
▪ Due to the integrated magnet, a safe distance must be kept from devices that can be damaged by magnetism.
▪ Remove batteries to prevent leakage if the device is stored at a temperature above 50 °C (122 °F) or not used for an extended period of time.
DANGER
▪ Due to the integrated magnet, a minimum distance of 20 cm (7.9″) must be maintained between a pacemaker and the hand-held meter
▪ Do not short-circuit.
▪ Do not expose the batteries to high temperature.
▪ Do not throw the batteries into fire.
E+E Elektronik Ges.m.b.H.
Langwiesen 7
4209 Engerwitzdorf | Austria
T +43 7235 605-0
F +43 7235 605-8
info@epluse.com
www.epluse.com

QG_Omniport40 | Version v1.1 | 11-2024 | All rights reserved