Dioche A7 Stand Alone Access Control and Reader

Dioche A7 Stand Alone Access Control and Reader-product-image

INTRODUCTION

This product is a Keypad standalone access control. 1500 user capacity and supporting 13.56MHz Mifare card (UID 7 bytes, 4 byets, Plus). It can be access by card, PIN, card + PIN. It also equipped with admin add/delete cards, door detection, external alarm and Wiegand input/output interface.
Features and Benefits

  • A7,A8 Zinc-alloy housing, A9 ABS shell
  • Waterproof, conforms to IP67
  • With Wiegand input & output, it can be used as not only
  • standalone, but also slave reader or access controller.
  • Equipped with admin cards, which can add/delete users quickly.
  • Pulse Mode or Toggle Mode
  • Door Bell button (A8,A9)

Specifications

Operating Voltage10-24V DC
Idle Current≤45mA
Active Current≤80mA
WaterproofIP67
User Capacity1500
Frequency13.56MHz
Card typeMifare (UID 7 bytes, 4 byets, Plus)
Read Range≤6cm
Wiegand InterfaceCard: Wiegand 26 bits or 34 bits, PIN: 4 bits
Lock Output Load≤2A
Alarm Output Load≤500mA

Packing List

Dioche-A7-Stand-Alone-Access-Control-and-Reader-product-image

INSTALLATION

  1.  Remove the back cover from the unit with screw.
  2. Drill hole on the wall according to the back size of the machine  and fix the back cover on the wall.
    Dioche-A7-Stand-Alone-Access-Control-and-Reader-2
  3. Thread the cable through cable hole, connect related cable. For  the un-used cable please separate with insulating tape.
  4. After wiring, install front casing and fix the back cover well with screws.

Wiring

Wire ColorFunctionNotes
OrangeNCRelay NC
PurpleCOMRelay COM
BlueNORelay NO
BlackGNDNegative Pole
RedDC+10-24V DC Power Input
YellowOPENRequest to Exit Button
BrownD_INDoor Contact
GreyALARM-Alarm Negative
GreenD0Wiegand output/input Data0
WhiteD1Wiegand output/input Data1
Grey & BlackBELLExternal BELL
Yellow & BlackBELLExternal BELL

Sound and Light Indication

Operation StatusLEDBuzzer
Stand by ModeRed light bright 
Enter program ModeRed light shines 
In the Program ModeOrange light bright 
Open lockGreen light brightOne beep
Operation failed Three beeps

Modify Admin Code

Programming StepKeystroke CombinationLED
Enter Program Mode* (Admin Code) #

(Factory default is 777777)

Red shines
Modify Admin Code0 (New Admin Code) # (Repeat New Admin Code) #Orange bright
Exit Program Mode*Red bright

Note: Admin should enter Program Mode, then the settings can be set or reset. For security, you must change the Admin Code and then keep in mind.

Factory Default Setting and Add Admin Cards
power off, press exit button , power on, release it until hear two beeps, then the red LED will be orange. It means the device is under the status of waiting for adding admin cards. Swiping two cards, the first card is “Admin Add Card”, the second card is “Admin Delete Card”, thenthe device will be in standby mode and the red light bright. Resets to factory default setting and adding admin cards are successful.
If you don’t need to add admin cards: Press “ ”* , power on, hold it for more than 10 seconds.
Note: Reset to factory default, the users’ information won’t be deleted.

STANDALONE MODE

Connection Diagram
Special Power Supply for Access ControlDioche-A7-Stand-Alone-Access-Control-and-Reader-3

DC power Supply for Access Control

Dioche-A7-Stand-Alone-Access-Control-and-Reader-4

Note: The electric locks must be connected with diode(1N4004), otherwise the device might be damaged. The white end of the diode is connected to positive pole of electric lock and the other end is connected to negative pole of the electric lock.

Add/Delete Users by Admin Cards (in standby mode)

 

Add users

Step 1: Read Admin Add Card Step 2: Read user cards

(Repeat step 2 for additional user cards) Step 3: Read Admin Add Card again to end

 

Delete users

Step 1: Read Admin Delete Card)

Step 2: Read user cards

(Repeat step 2 for additional user cards) Step 3: Read Admin Delete Card again to end

Enter and Exit Program Mode

Programming StepKeystroke Combination
Enter Program Mode* (Admin Code) #

(Factory default is 777777)

Exit Program Mode*

Add Users (ID number: 1-1500)

Programming StepKeystroke CombinationLED
Enter Program Mode* (Admin Code) #Red shines
Add Card User
Add Card: By Card

OR

Add Card: By ID number

OR

Add Card: By Card number

1 (Read Card) #

 

1 (Input ID number) # (Read Card)

 

1 (Input 8/10 digits Card number)#

 

 

Orange bright