DELTA - logoEBSU-CE2818SX1 PP0Y LFP Battery Container
Instruction ManualDELTA EBSU-CE2818SX1 PP0Y LFP Battery Container

Energy Storage Solution

LFP Battery Container

  • Compact design of standard 10-ft shipping container for easy transportation and installation
  • Built-in fire protection system, compliant with UL 9540A safety test standard
  • Battery system with built-in controls, offering flexible scalability from 708 kWh to 7.78 MWh

DELTA EBSU-CE2818SX1 PP0Y LFP Battery Container - icon

Fully-Integrated Battery Solutions

Redefining Safety and Performance with Effortless Installation,
Remarkable Scalability, and Integrated Fire Protection System
Delta’s LFP battery container is designed for grid-scale and medium to large-scale industrial energy storage applications. Built on a standard 10-ft shipping container with compact design and simple installation procedure, the battery system can be rapidly deployed.
LFP battery container is high energy density, offering scalability from 708 kWh to 7.78 MWh. This flexibility allows it to accommodate varying spatial and capacity requirements for different sites, optimizing land utilization.
In addition, LFP battery container features redundant communication support for the installation site with built-in controls, enhancing the communication stability of the energy storage system. It also incorporates several sensors and a fire protection system to ensure the safety of the energy storage system.DELTA EBSU-CE2818SX1 PP0Y LFP Battery Container - Fully-Integrated Battery

Features

High Energy Density with
Flexible and Scalable Configuration

  • High energy density, effectively utilizing space
  • Flexible configuration ranging from 708 kWh to 7.78 MWh battery capacity

Easy Transportation and Installation

  • Whole-container transport without the need to remove battery modules
  • Containers connected by flexible duct connectors on the top, tolerating positioning errors and reducing on-site installation time

Built-in Fire Protection System
Enhancing Inherent Safety

  • Real-time cell monitoring: temperature and voltage of each cell
  • Dual-redundant environmental sensors: smoke, heat, humidity, flammable gas, and flood
  • Fire protection system: detection system, gas venting system, aerosol fire extinguisher and fire sprinkler system

Integrated Control and Monitoring

  • Built-in controls seamlessly integrate batteries and PCSs without the need for additional equipment and space
  • Built-in Human-Machine Interface (HMI): on-site access to real-time field information
  • Dual-redundant communication enhanced of communication stability and monitoring efficiency

Product Configuration and Design

Battery SystemDELTA EBSU-CE2818SX1 PP0Y LFP Battery Container - Battery System

Reinforced Storage Container

  • Three-layer structure composed of double steel plate and fireproof rock wool boards (fire retardant up to 60 minutes)
  • Cables and wires in accordance with IEC 6033
  • IEEE 693 Recommended Practice for Seismic Design of Substations
  • Corrosion protection according to ISO 12944 C5M (C5H optional)
  • Access control for vandalism prevention

Battery Container
Redundant Detection System

  • Smoke detectors
  • Flammable gas detectors
  • Heat detectors
  • Door sensors
  • Flood detectors
  • Humidity sensors

Battery Module Protetcion

  • Real-time monitoring of each battery cell
  • Big data for aging/abnormality detection
  • Insulation design of battery module
  • Built-in fuse
  • Cell balancing mechanism

DELTA EBSU-CE2818SX1 PP0Y LFP Battery Container - Battery ContainerFire Safety Protection

  • Gas venting system
  • Aerosol fire extinguisher
  • Fire sprinkler system
  • Fire alarm siren & strobe

Safety Certification

  • UL 9540A
  • UL 1973
  • IEC 62619 including fire propagation
  • UN 38.3
  • IEC 60730
  • IEC 61000 -6-2/ -6-4
  • IEC 62477
  • CE / UKCA Mark

Software Interface

Human Machine Interface (HMI)

  • Easy Commissioning
    On-site view of real-time information on the battery system
  • Real-Time Monitoring
    Operation information, environment status, UPS status, warnings, and battery information (e.g. SoC, SoH, voltage, current, temperature), etc
  • Convenient Maintenance
    Service mode option enables technicians to maintain the battery system easily

DELTA EBSU-CE2818SX1 PP0Y LFP Battery Container - Software InterfaceBattery Management System (BMS)

  • Clear Overview of Battery Status
    Intuitive UI for real-time display of battery string parameters
  • Quick Diagnosis and Debugging
    Easy access to error codes, database, daily logs, and entry records

DELTA EBSU-CE2818SX1 PP0Y LFP Battery Container - Battery Management System

Specifications

TypeSingle Container (IEC Version)Battery System (IEC Version)
AIOBattery
Model NameEBSU-CE2818SX1 PP0Y1 EBSB-CE2818SX1 PS0Y1EBSB-CE2818S3PP0Y1 EBSB-CE2818S4PP0Y1EBSU-CE2818SX2 PP0Y1 EBSB-CE2818SX2 PS0Y1
Installed Capacity0 to 1416 kWh1770 kWh to 7788 kWh
Rated Power757 kW to 3333 kW
Battery CellLFP 280 Ah Cell
DC Voltage Range1089 to 1386 Vdc
String Configuration396S-1P
Modules per String18
Max. Charge/Discharge Current3080 A
Recommended DoD95%
Auxiliary Power220/380 Vac (3P4W) ±5%
Communication InterfaceEthernet
Communication ProtocolModbus
Environment
Environment ConditionOutdoor
Altitude< 2000m
Operating Temperature-30 ℃ to +50 ℃
Ambient Humidity0 to 100 % RH (non-condensing)
Storage Temperature1 month: -20 ℃ to +45 ℃, <70% RH ; 1 year: 0 ℃ to +35 ℃, <70% RH
Ingress ProtectionIP54; Type 3R, NEMA 3R compliance
Corrosion ResistanceCompliant with Severity-1 (IEC 60068-2-52); Passed 720-hour salt mist test (ISO 9227), ISO 12944 Level C5M
Container StandardISO 668
Seismic LevelIEEE 693 (0.5 G, 2% damping)
Operation
Measurement AccuracyVoltage: ±0.5 %; Current: ±1 % ; Temperature: ±2 ℃; SoC: ≤5 %
HMIFor monitoring and maintenance
BMS Log90 days
BMS Power BackupUPS power backup for 60 minutes
Time CalibrationNTP time synchronization
Safety Protection
Fire Safety EquipmentGas-venting system, aerosol fire extinguisher and fire sprinkler system
Detection Sensors (per Container)Heat (x2), smoke (x2), gas (x2), flood (x2), humidity (x4), door (x4)
Mechanical Information
Dimension (W x D x H)2438 × 2990 × 2896 mm (per Container)
WeightAIO Container: 12,000 kg (with 2 battery strings) Battery Container: 16,000 kg (with 4 battery strings)
  • Where X 1 can be 0,1,2, which indicates the number of battery strings.
  • Where X2 can be a number from 5 to 22, which indicates the number of battery strings.
  • Where Y1 is a serial number indicating the battery system version.

Specifications are subject to change without prior notice.
Please refer to the actual product purchased, and the latest version can be obtained from sales channels.

 

DELTA - logoDelta Electronics
16 Tungyuan Road, Chungli Industrial Zone, Taoyuan City 32063, Taiwan
TEL: +886 3 4526107
EISBG.Marketing@deltaww.com
www.deltaww.comDELTA EBSU-CE2818SX1 PP0Y LFP Battery Container - qr codehttps://www.deltaww.com/en-US/products/Energy-Storage-Systems/ALL/
More Information

Documents / Resources

DELTA EBSU-CE2818SX1 PP0Y LFP Battery Container [pdf] Instruction Manual
EBSU-CE2818SX1 PP0Y LFP Battery Container, EBSU-CE2818SX1, PP0Y LFP Battery Container, LFP Battery Container, Battery Container

References

Leave a comment

Your email address will not be published. Required fields are marked *