DELL-logoDELL C6400 PowerEdge Node Server

DELL-C6400-PowerEdge-Node-Server

Identifying the rail kit contents

Identify the components to install the rail:

  • Two static rail assemblies
  • Two optional chassis retention brackets
  • Four M5 screws
  • Four M5 cage nuts

DELL-C6400-PowerEdge-Node-Server-1

  1. static rail assembly (2)
  2. optional chassis retention bracket (2)
  3. M5 screw (4)
  4. M5 cage nut (4)

Installing and removing the

CAUTION: When installing rails in a square-hole rack, ensure that the square pegs slide into the square holes and sit firmly.
NOTE: The rails can be installed in both square and round hole racks.
NOTE: The support bracket must be removed if the rail cannot fit between the rack flanges.

  1. To install the rail:
    • Press the release latch on the rail.
    • Align the rail with the rack flange, ensuring that the rail pegs are seated in the designated rack holes.
    • Release the latch to lock the rail in place.
  2. To remove the rail, press the release latch and disengage each rail.

DELL-C6400-PowerEdge-Node-Server-2

  1. rack flange
  2. release latch (2)
  3. support bracket
  4. rail peg (4)

Installing and removing the system

  • To install and secure the system into the rack:
    • If installing the optional chassis retention bracket, insert two cage nuts in the two rack holes above each rail.
      NOTE: If the system is a 1U system, the optional chassis retention brackets cannot be installed. NOTE: The cage nuts must be installed before installing the system in the rack.
    • Position the system on the rail.
    • Hold the system rack ears and slide the system into the rack until the system is seated in place.
    • Tighten the thumbscrews to secure the system.
  •  To remove the system from the rack:
    • Loosen the thumbscrews to release the system.
    • Pull and remove the system out of the rail.

DELL-C6400-PowerEdge-Node-Server-3

  1. thumbscrew (2)
  2. rack ear (2)
  3. system
  4. cage nut (4)

Installing and removing the optional chassis retention bracket

WARNING: When shipping a rack with the system installed, ensure that the two chassis retention brackets are firmly seated on the system.

  1. To install the optional chassis retention bracket:
    • Place the bracket on the system.
    • Secure the bracket to the rack flange with two screws by using Phillips #2 screwdriver.
  2. To remove the optional chassis retention bracket, remove the screws securing the bracket.

DELL-C6400-PowerEdge-Node-Server-4

  1. cage nut (4)
  2. screw (4)
  3. chassis retention bracket (2)

WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed.
NOTE: A NOTE indicates important information that helps you make better use of your system.