SINOTIMER TM-919B

Benutzerhandbuch für den Digitaltimer TM-919B

Model: TM-919B | Brand: SINOTIMER

Einführung

The SINOTIMER TM-919B is a highly versatile 7-day, 24-hour programmable digital timer switch designed for automatic control of various electrical equipment. This device is ideal for applications requiring precise scheduling, such as street lamps, neon lights, water heaters, air conditioners, and agricultural facilities. Its robust design and user-friendly interface ensure reliable operation and easy setup.

Key features include a 30A load capacity, 16 ON/OFF programs, and a built-in rechargeable battery for memory backup during power failures. The timer is designed for DIN rail mounting, making it suitable for integration into electrical distribution boards.

Produkt überview

Front view of the Sinotimer TM-919B digital timer, showing the display and control buttons.

Abbildung 1: Vorderseite view of the TM-919B Digital Timer, displaying the time and control buttons for programming.

Seite view of the Sinotimer TM-919B digital timer, highlighting the DIN rail mounting mechanism.

Abbildung 2: Seite view of the TM-919B, illustrating its compact design and the integrated DIN rail mounting clip.

Front view of the Sinotimer TM-919B digital timer with dimensions indicated.

Abbildung 3: Vorderseite view of the TM-919B with approximate dimensions: 8.7cm height, 6cm width, and 4.5cm depth.

Sicherheitsvorkehrungen

Always disconnect power before installation or maintenance. Installation should be performed by a qualified electrician in accordance with local electrical codes. Do not expose the device to moisture or extreme temperatures. Ensure proper wiring to avoid damage to the unit or connected appliances.

Setup und Installation

  1. Montage: The TM-919B is designed for DIN rail mounting. Securely attach the timer to a standard 35mm DIN rail within your electrical distribution board.
  2. Verdrahtung:
    • Connect the main power supply (220-240V AC, 50/60Hz) to the input terminals (typically marked L and N or 1 and 2).
    • Connect the load (appliance) to the output terminals (typically marked 3, 4, 5 for a changeover switch). Refer to the wiring diagram on the device for precise connections. Ensure the load does not exceed 30A (resistive) or 15A (inductive).
  3. Erstes Einschalten: After wiring, restore power. The display should illuminate. The built-in battery will begin charging, which may take a few hours for full capacity.
  4. Zurücksetzen: If the display is erratic or you wish to clear all settings, press the "R" (Reset) button using a pointed non-metallic object. This will clear all programs and reset the clock.

Bedienungsanleitung

Aktuelle Uhrzeit einstellen

  1. Drücken Sie die "P" button (Program) once to enter time setting mode.
  2. Drücken "D+" um den aktuellen Wochentag einzustellen.
  3. Drücken "H+" um die aktuelle Stunde einzustellen.
  4. Drücken "M+" um die aktuelle Minute einzustellen.
  5. To switch between 12-hour (AM/PM) and 24-hour format, press "P" Und "H+" gleichzeitig.
  6. Drücken Sie die "P" button again to exit time setting and return to normal operation.

Programming ON/OFF Cycles (16 Programs)

Der Timer unterstützt bis zu 16 EIN/AUS-Programme. Jedes Programm besteht aus einer EIN-Zeit und einer AUS-Zeit.

  1. Drücken Sie die "P" button repeatedly to cycle through the program settings (1 ON, 1 OFF, 2 ON, 2 OFF, ..., 16 ON, 16 OFF). The display will show "1 ON", "1 OFF", etc.
  2. When "1 ON" is displayed, use "D+" to select the day(s) of the week for this ON event. Options include individual days, weekdays, weekends, or all days.
  3. Verwenden "H+" Und "M+" um die gewünschte Einschaltzeit (Stunde und Minute) einzustellen.
  4. Drücken "P" again to move to "1 OFF". Set the day(s), hour, and minute for the OFF event using "D+", "H+", Und "M+".
  5. Repeat steps 2-4 for any additional programs (up to 16).
  6. Nachdem Sie alle gewünschten Programme eingestellt haben, drücken Sie die Taste "P" button until the display shows the current time, or wait for 30 seconds for it to automatically return to normal operation.

Manuelle Übersteuerung

The timer has a manual override function to temporarily change the output state.

  • Drücken Sie die "HANDBUCH" button (or a button labeled with a hand icon, if present) repeatedly to cycle through modes:
    • AUF: Der Ausgang ist dauerhaft eingeschaltet.
    • AUTO EIN: Die Ausgabe ist aktuell gemäß dem Programm eingeschaltet.
    • AUS: Der Ausgang ist dauerhaft ausgeschaltet.
    • AUTOM. AUS: Die Ausgabe ist gemäß dem Programm aktuell AUS.
  • Select "AUTO ON" or "AUTO OFF" to ensure the timer follows the programmed schedule.

Wartung

The SINOTIMER TM-919B is designed for low maintenance. Keep the device clean and free from dust. Do not use abrasive cleaners. The built-in rechargeable battery is designed for long life and typically does not require replacement under normal operating conditions. If the display frequently goes blank during power outages, the battery may need servicing by a qualified technician.

Fehlerbehebung

ProblemMögliche UrsacheLösung
Anzeige ist leer.Keine Stromversorgung; interne Batterie entladen.Check power connections. Allow unit to charge for several hours after initial power-up.
Der Timer schaltet sich zu den programmierten Zeiten nicht ein/aus.Incorrect programming; manual override set to ON/OFF; current time incorrect.Verify program settings. Ensure manual override is set to "AUTO ON" or "AUTO OFF". Correct current time.
Der Ausgang ist entweder immer EIN oder immer AUS.Manuelle Übersteuerung aktiviert.Press the "MANUAL" button until "AUTO ON" or "AUTO OFF" is displayed.
Erratic display or unresponsive buttons.System error; static electricity.Perform a full reset by pressing the "R" button. Reprogram all settings.

Technische Daten

ParameterWert
ModellTM-919B
Stromversorgung220-240 V Wechselstrom, 50/60 Hz
Tragfähigkeit30A (Resistive), 15A (Inductive) @ 250V AC
Studiengänge16 Ein-/Ausschaltvorgänge pro Tag/Woche
Mindestintervall1 Minute
Zeitraum1 Minute bis 168 Stunden (7 Tage)
Interne Batterie1.2 V/40 mA wiederaufladbar (für Speichersicherung)
Zeitfehlerkorrektur±30 seconds per week
Abmessungen (L x B x H)87 mm x 60 mm x 45 mm (ca. 8.7 x 4.5 x 6 cm)
MontageDIN-Schiene
MaterialABS + Elektronische Komponenten
ZertifizierungenIEC 60367, CE

Garantie und Support

Specific warranty information for this product is not provided in the available documentation. For warranty claims or technical support, please contact the retailer or manufacturer directly. Ensure you have your purchase receipt and product model number (TM-919B) ready when contacting support.

© 2023 SINOTIMER. Alle Rechte vorbehalten.