Mi-Heat ETR2

Mi-Heat ETR2 DIN Rail Mount Thermostat User Manual

Model: ETR2

Brand: Mi-Heat

1. Einleitung und Produktübersichtview

The Mi-Heat ETR2 controller is a sophisticated DIN rail mount thermostat designed for efficient and economical control of ice and snow melting systems. It is particularly suitable for use in gutters and small outdoor areas, ensuring surfaces remain clear and safe during cold weather conditions.

The ETR2 system operates by utilizing signals from external temperature and humidity sensors (such as ETF-744/99, ETOG-55/56, or ETOR-55). This intelligent control mechanism activates the heating system only when both low temperatures and humidity (indicating rain or snow) are detected, thereby optimizing energy consumption.

Hauptmerkmale:

  • Suitable for gutters and small outdoor areas.
  • Economical energy consumption through combined temperature and humidity sensor input.
  • Automatic activation of the snow melting system upon humidity detection.
  • Output Relay: 16 A potential-free, capable of switching up to 3600 W.
  • Adjustable Temperature Range: 0-10 °C.
  • Adjustable Follow-up Time: 1-5 hours.
  • Mounting: Standard DIN rail.
  • Protection Type: IP20.
Mi-Heat ETR2 Thermostat Front View

Abbildung 1: Vorderseite view of the Mi-Heat ETR2 DIN Rail Mount Thermostat, showing control dials for temperature and time settings.

2. Sicherheitshinweise

Bitte lesen Sie diese Sicherheitshinweise vor der Installation und Inbetriebnahme sorgfältig durch. Die Nichtbeachtung dieser Hinweise kann zu Stromschlag, Brand oder Beschädigung des Produkts führen.

  • Die Installation muss von einem qualifizierten Elektriker gemäß den örtlichen Elektrovorschriften und -bestimmungen durchgeführt werden.
  • Vor Beginn jeglicher Installations-, Verkabelungs- oder Wartungsarbeiten muss unbedingt die Hauptstromversorgung unterbrochen werden.
  • The device is designed for indoor installation within a control cabinet or enclosure with IP20 protection.
  • Setzen Sie das Gerät keiner Feuchtigkeit, extremen Temperaturen oder korrosiven Umgebungen aus.
  • Verify all connections are secure and correctly wired to prevent short circuits or malfunctions.
  • The maximum load for the output relay is 3600 W (16 A). Do not exceed this rating.

3. Einrichtung und Installation

The ETR2 thermostat is designed for DIN rail mounting within a suitable electrical enclosure. Ensure adequate space for wiring and ventilation.

3.1 Montage:

  1. Securely attach the ETR2 thermostat to a standard DIN rail inside your control cabinet.
  2. Ensure the mounting bracket is firmly engaged.

3.2 Kabelverbindungen:

Refer to the wiring diagram below for correct sensor and power connections. The ETR2 requires external temperature and humidity sensors for operation.

Mi-Heat ETR2 Thermostat Wiring Diagram

Figure 2: Wiring diagram for the Mi-Heat ETR2 Thermostat, showing connections for ETOG and ETF/ETOR sensors.

  • Power Supply (Terminals 1-2): Connect the main power supply to these terminals. Ensure the voltage matches the device requirements (typically 230V AC, check product label if unsure).
  • Heating Cable/Mat (Terminals 5-7): Connect your heating cable or mat to the potential-free relay output. Ensure the total wattage überschreitet nicht 3600 W.
  • ETOG Sensor (Terminals 8-14): For ground-mounted sensors (e.g., ETOG-55/56), connect the wires according to the color code shown in Figure 2.
  • ETF/ETOR Sensors (Terminals 8-14): For outdoor temperature sensors (e.g., ETF-744/99) or gutter sensors (e.g., ETOR-55), connect the wires as indicated in Figure 2. Note that some connections might be "Do Not Connect" depending on the sensor type.

After all connections are made, double-check the wiring for correctness and security before restoring power.

4. Bedienungsanleitung

The ETR2 thermostat features two main rotary dials for setting the desired operational parameters.

Mi-Heat ETR2 Thermostat Control Dials

Figure 3: Close-up of the ETR2 thermostat's control dials.

4.1 Temperature Setting (TEMP.SET °C):

  • This dial adjusts the temperature threshold at which the system will operate.
  • The range is typically from 0°C to 10°C.
  • Set the dial to the desired temperature below which ice or snow melting is required. For example, setting it to 2°C means the system will only activate if the temperature drops below 2°C AND humidity is detected.

4.2 Follow-up Time Setting (TIME.SET h):

  • This dial sets the duration (in hours) for which the heating system will continue to operate after the humidity sensor no longer detects moisture.
  • The range is typically from 1 to 5 hours.
  • This feature ensures that any residual moisture is evaporated, preventing immediate refreezing. Adjust this time based on local climate conditions and the specific application.

4.3 Operation Logic:

The ETR2 thermostat activates the connected heating system when the following two conditions are met simultaneously:

  1. The ambient temperature (as measured by the temperature sensor) falls below the set TEMP.SET value.
  2. Humidity (rain or snow) is detected by the humidity sensor.

Once activated, the system will run until both conditions are no longer met, plus the duration of the set TIME.SET follow-up period.

5. Wartung

The Mi-Heat ETR2 thermostat is designed for reliable, long-term operation with minimal maintenance. However, periodic checks can help ensure optimal performance.

  • Sichtprüfung: Periodically inspect the thermostat and its wiring for any signs of damage, loose connections, or corrosion.
  • Sensorprüfung: Ensure external temperature and humidity sensors are clean and free from debris that could obstruct their function.
  • Reinigung: If necessary, gently clean the exterior of the thermostat with a dry, soft cloth. Do not use abrasive cleaners or solvents.
  • Stromabschaltung: Always disconnect power before performing any inspection or cleaning inside the control cabinet.

6. Fehlerbehebung

If the ETR2 thermostat or your snow melting system is not functioning as expected, consider the following:

  • System wird nicht aktiviert:
    • Check if the main power supply to the thermostat is active.
    • Verify that both the temperature is below the set point AND humidity is detected by the sensor.
    • Inspect sensor wiring for loose connections or damage.
    • Ensure sensors are clean and properly installed in their respective locations (e.g., ground, gutter).
  • System Running Continuously:
    • Check the TIME.SET dial; the system will run for this duration after humidity clears.
    • Inspect the humidity sensor for persistent moisture or debris that might be causing a false reading.
    • Verify the temperature sensor is functioning correctly and not reporting an artificially low temperature.
  • No Power to Heating Elements:
    • Check the thermostat's output relay status (if visible indicator is present).
    • Verify connections to the heating cable/mat (Terminals 5-7).
    • Stellen Sie sicher, dass das Gesamtwasser vorhanden isttage of the heating elements does not exceed the 3600 W limit.

If problems persist after checking these points, please contact Mi-Heat customer support.

7. Spezifikationen

Modellnummer:ETR2
Hersteller:infrarot-fussboden-de (Mi-Heat)
Artikel-Nr.:1221
Montageart:DIN-Schienenmontage
Ausgangsrelais:16 A potential-free, max. 3600 W
Temperatur-Einstellbereich:0-10 °C
Follow-up Time Adjustment:1-5 Stunden
Energieverbrauch:3 VA
Umgebungstemperatur:0/+50°C
Schutzart:IP20
Material:Metall
Enthaltene Komponenten:Humidity probe, temperature sensor, DIN rail mounting bracket (sensors sold separately or as part of a kit)

7.1 Abmessungen:

Mi-Heat ETR2 Thermostat Dimensions Diagram

Figure 4: Dimensional drawing of the Mi-Heat ETR2 Thermostat (dimensions in mm).

  • Höhe: 85 mm
  • Breite: 52 mm
  • Depth: 48.8 mm (including DIN rail clip)

8. Garantieinformationen

For detailed warranty information regarding your Mi-Heat ETR2 thermostat, please refer to the specific warranty documentation provided with your purchase or contact your point of sale. Warranty terms and conditions may vary based on region and retailer.

9. Unterstützung und Kontakt

Should you have any questions regarding the Mi-Heat ETR2 thermostat, its installation, operation, or any other product-related inquiries, please do not hesitate to contact our customer support team.

Our support team is available to assist you:

  • Verfügbarkeit: Monday to Friday, from 09:00 to 16:00 (German time).
  • Please refer to your purchase documentation or the Mi-Heat official website for specific contact details (phone number, email address).

We offer support and shipping directly from Germany to ensure prompt assistance.

© 2024 Mi-Heat. Alle Rechte vorbehalten.

This manual is for informational purposes only. Mi-Heat reserves the right to make changes to the product specifications without prior notice.