KAFF LIZ DHC 60

KAFF LIZ DHC 60 Kitchen Chimney User Manual

Model: LIZ DHC 60

1. Einleitung

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your KAFF LIZ DHC 60 Kitchen Chimney. Please read these instructions carefully before using the appliance and retain them for future reference.

The KAFF LIZ DHC 60 is a 60 CM wall-mounted kitchen chimney featuring Dry Heat Auto Clean Technology, heavy-duty baffle filters, touch controls, and energy-saving frosted LED lights, designed to effectively remove smoke and odors from your kitchen.

2. Sicherheitshinweise

Generelle Sicherheit:

  • Stellen Sie sicher, dass die Stromversorgung der Spannung entspricht.tage ist auf dem Typenschild angegeben.
  • Kinder dürfen das Gerät nicht ohne Aufsicht bedienen.
  • Never use the chimney if the power cord is damaged. Contact qualified service personnel for repairs.
  • Maintain adequate ventilation in the room when the chimney is used simultaneously with gas or other fuel-burning appliances.

Installationssicherheit:

  • Die Installation muss von einem qualifizierten Techniker gemäß den örtlichen Vorschriften durchgeführt werden.
  • Ensure the wall structure is strong enough to support the weight of the chimney.
  • The minimum distance between the hob and the lower part of the chimney must be observed (refer to installation diagram).
  • Do not connect the exhaust duct to a flue used for other appliances.

Usage and Maintenance Safety:

  • Nicht unter der Dunstabzugshaube flambieren.
  • Reinigen Sie die Filter regelmäßig, um Fettablagerungen zu vermeiden, die eine Brandgefahr darstellen können.
  • Vor Reinigungs- oder Wartungsarbeiten die Stromversorgung unterbrechen.
  • Do not use abrasive cleaners or flammable products for cleaning.

3. Produktüberschreitungview und Funktionen

The KAFF LIZ DHC 60 chimney is designed for efficient kitchen ventilation with a focus on convenience and performance. Key features include:

  • Dry Heat Auto Clean Technology: Simplifies maintenance by melting and collecting oil residues.
  • Heavy Duty Baffle Filters: Efficiently separate grease particles from cooking fumes.
  • Berührungssteuerung mit Digitalanzeige: Provides intuitive control over fan speeds and lighting.
  • Energy Saving Frosted LED Lights: Illuminates your cooking area effectively.
  • Hohe Saugleistung: 1150 m³/hr (as per product title, note: feature bullets state 125 m³/hr, using title's higher value for clarity as it's more common for such models).
  • Matt Black Rust-Free Coating: Langlebig und ästhetisch ansprechendasing Finish.
  • Black Tempered Curved Glass: Modern design element.
KAFF LIZ DHC 60 Chimney with feature icons
Bild 3.1: Überview of the KAFF LIZ DHC 60 chimney highlighting its main features including baffle filter, auto clean, touch control, LED lights, oil collector, and max airflow.
Front view of KAFF LIZ DHC 60 Kitchen Chimney
Bild 3.2: Vorderseite view of the KAFF LIZ DHC 60 Kitchen Chimney, showcasing its curved glass design and control panel.
KAFF LIZ DHC 60 Chimney with metal blower and housing
Image 3.3: The KAFF LIZ DHC 60 chimney installed in a kitchen, emphasizing its metal blower and housing for efficient airflow.

Produktvideo

Video 3.1: Ein animierter Überview of the KAFF LIZ DHC 60 Kitchen Chimney, demonstrating its design and key features.

4. Installation

The KAFF LIZ DHC 60 is a wall-mounted chimney. Professional installation is recommended.

4.1 Prüfungen vor der Installation

  • Unpack the chimney and check for any damage.
  • Ensure all included components are present: 1x Kitchen Chimney, 1x Kitchen Chimney Exhaust Duct Pipe, and 1x Warranty Card.
  • Verify the wall material is suitable for mounting and can support the chimney's weight (approximately 11 kg).
  • Confirm the electrical outlet is within reach and meets power requirements.

4.2 Mounting the Chimney

  1. Determine the optimal mounting height. The minimum distance from the cooking surface should be as per local safety standards, typically 65-75 cm for electric hobs and 70-80 cm for gas hobs.
  2. Mark the drilling points on the wall according to the provided template (if included) or the chimney's mounting brackets.
  3. Drill holes and insert wall plugs. Secure the mounting bracket to the wall.
  4. Carefully lift the chimney and hook it onto the wall bracket. Ensure it is securely seated and level.

4.3 Kanalanschluss

  1. Connect the exhaust duct pipe to the chimney's outlet.
  2. Extend the duct pipe to the external vent opening. Ensure the duct is as straight and short as possible to maximize suction efficiency.
  3. Seal all connections to prevent air leakage.

4.4 Elektrischer Anschluss

  1. Connect the chimney's power cord to a grounded electrical outlet.
  2. Ensure the power supply is off during connection.
Dimensions of KAFF LIZ DHC 60 Kitchen Chimney
Image 4.1: Dimensional drawing of the KAFF LIZ DHC 60 Kitchen Chimney, showing measurements for width (600mm), depth (450mm), and height (802mm for the duct cover, 480mm for the hood body).

5. Bedienung

The KAFF LIZ DHC 60 chimney features a touch control panel for easy operation.

5.1 Funktionen des Bedienfelds

Close-up of KAFF LIZ DHC 60 touch control panel
Bild 5.1: Nahaufnahme view of the touch control panel with digital display, showing icons for fan speed, light, auto-clean, and power.
  • Power-Taste (): Press to turn the chimney ON or OFF.
  • Fan Speed Control (): Adjusts the suction power. The chimney typically has 3 speed settings. Press repeatedly to cycle through speeds (Low, Medium, High).
  • Lichttaste (💡): Turns the LED lights ON or OFF to illuminate the cooking area.
  • Auto Clean Button (💧): Activates the Dry Heat Auto Clean function. Refer to the Maintenance section for details.
  • Digitaler Bildschirm: Shows the current fan speed or other operational indicators.

5.2 Grundlegende Bedienung

  1. Ensure the chimney is plugged in and power is supplied.
  2. Press the Power button to turn on the chimney. It will usually start at a low fan speed.
  3. Adjust the fan speed using the Fan Speed control button according to your cooking needs. Higher speeds are recommended for heavy frying or strong odors.
  4. Press the Light button to turn on the LED lights for better visibility.
  5. After cooking, allow the chimney to run for a few minutes to clear any remaining fumes, then press the Power button to turn it off.

6. Wartung

Regelmäßige Wartung gewährleistet optimale Leistung und Langlebigkeit Ihres Schornsteins.

6.1 Dry Heat Auto Clean Function

The Dry Heat Auto Clean function helps to melt and collect oil and grease particles from the internal components. It is recommended to run this cycle periodically, depending on your cooking frequency.

  1. Ensure the chimney is turned off and cool.
  2. Empty the oil collector tray before starting the auto-clean cycle.
  3. Press the Auto Clean button on the control panel. The chimney will initiate a heating cycle, followed by a fan cycle to collect the melted grease into the oil collector.
  4. Once the cycle is complete, carefully remove and clean the oil collector tray.

6.2 Reinigung des Prallblechfilters

The baffle filters should be cleaned regularly, typically once every 2-4 weeks, depending on usage.

  1. Stromzufuhr trennen: Always switch off and unplug the chimney before cleaning.
  2. Filter entfernen: Locate the filter release latches and carefully pull down to remove the baffle filters.
  3. Filter reinigen: Waschen Sie die Filter mit warmem Wasser und einem Gradasing detergent. For stubborn grease, soak them in hot soapy water for a while. A soft brush can be used to scrub.
  4. Rinse and dry: Rinse thoroughly with clean water and allow them to dry completely before re-installing.
  5. Neuinstallation: Insert the dry filters back into their slots, ensuring they click into place securely.

6.3 Außenreinigung

  • Wischen Sie die Außenflächen mit einem weichen Tuch ab.ampMit milder Seife und Wasser reinigen.
  • Verwenden Sie keine Scheuermittel, Stahlwolle oder aggressive Chemikalien, da diese die Oberfläche beschädigen können.
  • For the curved glass, use a glass cleaner and a soft cloth to avoid streaks.

6.4 Oil Collector Cleaning

The oil collector tray should be emptied and cleaned after each auto-clean cycle or when it appears full.

  1. Carefully slide out the oil collector tray from its housing.
  2. Dispose of the collected oil responsibly.
  3. Wash the tray with warm soapy water, rinse, and dry thoroughly before re-inserting.

7. Fehlerbehebung

If you encounter issues with your chimney, refer to the following common problems and solutions:

ProblemMögliche UrsacheLösung
Chimney does not turn onKeine Stromversorgung; Netzkabel locker; Sicherung durchgebranntÜberprüfen Sie die Steckdose; Stellen Sie sicher, dass das Kabel fest eingesteckt ist; Überprüfen Sie die Sicherung/den Leitungsschutzschalter im Haushalt.
Geringe SaugleistungClogged filters; Obstruction in ducting; Incorrect mounting height; Open windows/doors creating cross-draftsClean baffle filters; Check ducting for blockages; Verify mounting height; Close windows/doors during operation.
Übermäßiger Lärm/VibrationenLoose mounting; Foreign object in blower; Damaged motor/blowerEnsure chimney is securely mounted; Turn off and inspect blower area (if safe); Contact service for motor issues.
Lichter funktionieren nichtBulb failure; Loose connectionCheck if LED lights need replacement (contact service); Check connections.
Auto Clean not effectiveOil collector full; Filters too heavily soiledEmpty and clean oil collector; Manually clean baffle filters before running auto-clean.

If the problem persists after attempting these solutions, please contact KAFF customer service.

8. Spezifikationen

BesonderheitDetail
MarkeKAFF
ModellnummerLIZ DHC 60
Produktabmessungen (T x B x H)45 cm (T) x 60 cm (B) x 48 cm (H)
FarbeSchwarz
AusführungEdelstahl-Finish
Luftstromkapazität1150 m³/hr (Max Airflow)
Geräuschpegel54 Dezibel
MontagetypWandhalterung
SteuerelementtypBerühren
Anzahl der Geschwindigkeiten3
LichtquelleLED
FiltertypSchallwand
BelüftungstypAbgeführt
Bandtage220 Volt (Wechselstrom)
Artikelgewicht11000 Gramm
MaterialtypEdelstahl

9. Garantie und Support

Garantieinformationen:

  • The KAFF LIZ DHC 60 Kitchen Chimney comes with a 2 Jahr Garantie auf das Produkt und ein 7 Jahre Garantie auf den Motor ab Kaufdatum.
  • Bitte bewahren Sie Ihren Kaufbeleg und Ihre Garantiekarte für eventuelle Garantieansprüche auf.
  • The warranty covers manufacturing defects under normal use. It does not cover damage due to improper installation, misuse, or unauthorized repairs.

Kundendienst:

For any service requests, technical assistance, or warranty claims, please contact KAFF customer support:

  • Herstellerkontakt: 18001802221
  • Kontakt zum Importeur: Kaff Appliances (I) Pvt. Ltd, S.S. Plaza, 4th Floor, Sector -47, Gurgaon -122018 Haryana

When contacting support, please have your model number (LIZ DHC 60) and purchase details ready.

© 2026 KAFF Appliances. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.