Mi-Heat E51
Benutzerhandbuch für das digitale Raumthermostat Mi-Heat E51
Modell: E51
Brand: Mi-Heat
1. Einleitung
The Mi-Heat E51 digital room thermostat is designed for precise temperature control of electric and water-based underfloor heating systems. It features a backlit display, a 7-day weekly programming function, and frost protection. The thermostat utilizes both an internal room sensor and an external floor sensor to maintain your desired temperature, ensuring comfort and energy efficiency.
Hauptmerkmale:
- Hintergrundbeleuchtetes LCD-Display
- Weekly Programmable (5/2, 6/1, or 7-day modes)
- Integrated Room Sensor and External Floor Sensor
- Display Calibration/Offset Function
- Frostschutzfunktion
- Key Lock / Child Lock
2. Sicherheitshinweise
- Die Installation muss von einem qualifizierten Elektriker gemäß den örtlichen Verdrahtungsvorschriften durchgeführt werden.
- Always disconnect power at the main circuit breaker before installation, maintenance, or removal of the thermostat.
- Do not expose the thermostat to moisture or extreme temperatures.
- Stellen Sie sicher, dass alle Verbindungen sicher sind, um elektrische Gefahren zu vermeiden.
- Dieses Gerät ist nur für den Gebrauch in Innenräumen vorgesehen.
3. Packungsinhalt
Überprüfen Sie, ob alle Artikel im Paket vorhanden sind:
- Mi-Heat E51 Room Thermostat
- External Floor Sensor (NTC 10 kOhm with 2m lead)
- Befestigungsschrauben
- Bedienungsanleitung

4. Technische Daten
| Besonderheit | Spezifikation |
|---|---|
| Montagetyp | Unterputz |
| Version | Verdrahtet |
| Betriebslautstärketage | 230 V |
| max. Schaltleistung | 16 A / 3680 W |
| Steuerungstyp | Two-point control ON/OFF |
| Betriebstemperatur | 5-50°C |
| Sensor | Internal and external, NTC with 2m lead |
| Temperaturregelbereich (intern) | 0-55°C (Room sensor) |
| Temperaturregelbereich (extern) | 5-55°C (Floor sensor) |
| Frostschutz | Ja |
| Floor Limit Range | 5-50°C |
| Display/Hintergrundbeleuchtung | Ja/Ja |
| Protection Class IP | IP21 |
| Abmessungen (BxHxT) | 80 x 90 x 13/43 mm |
5. Installation
The Mi-Heat E51 thermostat is designed for flush-mounted installation in standard wall boxes. Ensure power is disconnected before proceeding.
5.1. Abmessungen

5.2. Verkabelung
Refer to the wiring diagram below for proper connection. The thermostat supports both electric underfloor heating and water-based underfloor heating (via an actuator).

Verdrahtungsschritte:
- Stellen Sie sicher, dass der Strom am Hauptleistungsschalter ausgeschaltet ist.
- Connect the Live (L) and Neutral (N) power supply wires to the corresponding terminals on the thermostat.
- Connect the heating element or actuator wires to the designated output terminals.
- Connect the external floor sensor cable to the sensor terminals.
- Carefully place the thermostat into the wall box and secure it with the provided screws.
- Die Stromversorgung wiederherstellen und den Thermostat testen.

6. Bedienung
The Mi-Heat E51 thermostat features an intuitive interface with a backlit LCD display and several control buttons.
6.1. Display and Buttons Overview

Tastenfunktionen:
- Selection Button (Book icon): Used to enter menu, confirm settings, or switch modes.
- Increase Value Button (Up arrow): Used to increase temperature, time, or navigate menu options.
- Decrease Value Button (Down arrow): Used to decrease temperature, time, or navigate menu options.
- On/Off Button (Power icon): Schaltet den Thermostat ein oder aus.
6.2. Grundlegende Bedienung
- Ein-/Ausschalten: Press the Power button to turn the thermostat on or off.
- Temperatur einstellen: When the thermostat is on, use the Up/Down arrow buttons to adjust the desired set temperature.
- Key Lock / Child Lock: To activate or deactivate the key lock, press and hold the Selection button for a few seconds until the key icon appears/disappears on the display.
6.3. Wöchentliches Programm
The thermostat allows for 7-day weekly programming with options for 5/2 (weekday/weekend), 6/1 (6 days/1 day), or 7-day individual programming. This feature enables you to set different temperatures for various times of the day across the week.

So erstellen Sie ein wöchentliches Programm:
- Press and hold the Selection button to enter the programming menu.
- Use the Up/Down arrows to navigate through the programming options (e.g., 5/2, 6/1, 7-day mode, time settings, temperature settings for each event).
- Press the Selection button to confirm each setting and move to the next.
- Wiederholen Sie den Vorgang für alle gewünschten Zeiträume und Tage.
- Exit the menu by pressing the Selection button until the main display reappears, or wait for it to time out.
6.4. Frost Protection Function
The frost protection function prevents the temperature from dropping below a set minimum (typically 5°C) to protect pipes and the heating system from freezing. This function is active when the thermostat is in standby or when specifically enabled in the settings.

7. Wartung
Das Mi-Heat E51 Thermostat benötigt nur minimalen Wartungsaufwand.
- Reinigung: Wischen Sie das Display ab und casinMit einem weichen, trockenen Tuch abwischen. Keine Scheuermittel, Lösungsmittel oder chemische Sprays verwenden, da diese die Oberfläche beschädigen können.
- Inspektion: Periodically check the thermostat for any visible damage or loose connections. If any issues are found, disconnect power and consult a qualified technician.
8. Fehlerbehebung
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Thermostat schaltet sich nicht ein | Keine Stromversorgung; lose Verkabelung; durchgebrannte Sicherung/ausgelöster Schutzschalter | Check main power supply; Verify wiring connections; Check and reset circuit breaker/replace fuse. |
| Heizung schaltet sich nicht ein | Set temperature is below room/floor temperature; Thermostat in OFF mode; Wiring issue | Increase set temperature; Ensure thermostat is ON; Check wiring connections to heating system. |
| Ungenaue Temperaturanzeige | Sensor malfunction; Incorrect sensor type selected; Thermostat placed near heat source/draft | Check sensor connection; Verify sensor type in settings; Relocate thermostat if possible or use calibration function. |
| Display not working or flickering | Power fluctuation; Internal fault | Cycle power to the thermostat; If problem persists, contact support. |
| Cannot change settings (Key Lock active) | Key Lock / Child Lock is enabled | Press and hold the Selection button until the key icon disappears to deactivate the lock. |
9. Garantie und Support
For support or inquiries regarding your Mi-Heat E51 thermostat, please contact us Monday - Friday from 09:00 to 16:00. We offer support and shipping directly from Germany.
Refer to your purchase documentation or retailer for specific warranty details and terms.