Danfoss logo

MAKING MODERN LIVING POSSIBLE

Danfoss TS715Si Electronic Single Channel Time Switch

TS715Si
Electronic Single Channel Timeswitch
with Service Interval Timer
Installation Guide
Danfoss Heating

TS715Si Electronic Single Channel Time Switch

For a large print version of these instructions please call Marketing on 0845 121 7400.

Danfoss TS715Si Electronic Single Channel Time Switch - icon 4

Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. All trademarks in this material are property of the respective companies.
Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

Installation Overview

Please Note:
This product should only be installed by a qualifi ed electrician or competent heating installer and should be in accordance with the current edition of the IEEE wiring regulations.

Product Specifi cation

Specification230V model24V model
Power supply230 Vac, ±15%, 50/60 Hz24 Vac, ±15%, 50/60 Hz
Switching action1 x SPDT voltage free, Type 1B
Switch rating24-230 Vac, 3(1)A
Battery back-up24 hours minimum
Setting/Running Accuracy± 1 minute
Dimensions, mm (W, H, D)135 x 88 x 32
Design standardEN 60730-2-7
Control Pollution SituationDegree 2
Rated Impulse Voltage2.5 kV
Ball Pressure Test75°C

Installation

  • Remove wallplate from unit by unscrewing the two screws on the bottom edge of the unit.
  • From the top left hand corner of the wallplate, there must be clearances of at least 140 mm to the right, 15mm to the left, 30mm above and 100mm below in order to mount the plug-on module.
  • The wallplate must be securely mounted either directly to the wall using suitable wood screws or to a fl ush mounted 1-gang electrical accessory box using M3.5 screws.
  • Cable access can either be from behind for concealed cabling, or from below for surface cabling. If surface cable is used, cut out cable access slot on plug-on module prior to mounting.
  • For wiring connections refer to diagram below.
    TS715 Si models are double insulated and do not require an earth connection, however a parking terminal is provided on the wallplate. This is clearly marked with an Earth symbol.
  • Prior to mounting the plug-on module, DIL switches on the rear of the plug-on module must be set. See diagram on page 6 for available options.
  • Mount plug-on module to wallplate by locating tabs on top of wallplate in apertures on rear of module, hinge down and press fi rmly to wallplate before tightening securing screws on bottom of wallplate.

3.1 Wiring
For wiring conversion tables please see pages 10-13).

Danfoss TS715Si Electronic Single Channel Time Switch - Wiring

Please Note:
Link terminals L and 1 for standard mains voltage operated systems.
On 24 volt models power supply must be wired to A & B on wallplate.

Please Note:
Always switch off mains fi rst and never fi t programmer to a live wallplate.

3.2 DIL Switch Settings
Before mounting the unit, ensure the 4 DIL switches on the rear have been moved to the required settings.

Danfoss TS715Si Electronic Single Channel Time Switch - DIL Switch Settings

Tick the INSTALLER SETTING box on the inside fl ap label to notify user in which mode their unit is set (24hr, 5/2 day or 7 day).

INSTALLER SETTING
24 Hour
5+2 Day
7 Day

Advanced Programming Options

To enter advanced programming press PROG, + and DAY/HOL together and hold for 5 seconds.

Option 1 – (3 or 2 On/Off s per day)
Use + or – to change between 3 or 2 on/off s each day.

Danfoss TS715Si Electronic Single Channel Time Switch - programming

Option 2 – (Disable or enable auto time change)
Press NEXT, then use + or – to change between auto time change enabled to auto time change disabled.

Danfoss TS715Si Electronic Single Channel Time Switch - programming 2

Option 8 – (Advanced Copy Functions)
Press NEXT, then + or – to change between the following copy options:
(0) Standard copy in 7 day and 5+2 day.
(1) Enhanced copy in 7 day, standard copy in 5+2 day.
(2) Enhanced copy in 7 day and AB copy in 5+2 day.
For an explanation of the copy features and how to use them please see below.
Press PROG to return to RUN.

5.0 Copy Functions Explained
There are 3 possible copy functions available. These are; Standard Copy, Enhanced Copy, and AB copy. Copy functions are enabled/ disabled in the Advanced Programming Options (page 6).
Standard Copy: Pressing copy will copy the previous days events into the displayed day. The unit will then display the 1st event for the new day. This copy function is present only if the unit is set to run in 5+2 or 7 day mode.

Enhanced Copy: The enhanced copy function is available in 7 day mode only. This allows any day to be copied to any other day, or days.
To use the enhanced copy function go into the event programming using the PROG button, then:

  1. Use the DAY button to fi nd the day to be copied from.
  2. Press the COPY button to select the day to be copied from. When selected, the day should begin to fl ash.
  3. Use the DAY button to fi nd the day to be copied to.
  4. Press COPY button to copy the selected day.
  5. Repeat steps 3 and 4 to select and copy other days.
  6. To stop copying, use the DAY button to go back to the fl ashing day and press the COPY button. The previously fl ashing day will stop fl ashing to indicate it has been de-selected.

NOTE: When a day has been copied to, it will remain visible and not flashing when the DAY button is used to select other days.

AB Copy: The AB copy function is available in 5+2 mode only and only if activated in the Advanced Programming setting.
A and B days, when selected, can be any group of days e.g. 5+2, 4+3 etc. The days do not have to run in sequence. For example, to operate in a 5+2 day mode the days can be set as follows:

A DaysB Days
Mon Tues Thurs Fri SatWed Sun

To use the AB copy function – press the PROG button:

  1. This will show the “A” days, with all the days selected.
  2. Use the DAY button to highlight a day.
  3. Subsequent presses of the DAY button will increment through the days.
  4. Press the + button to select a specifi c day as an “A” day, or press the – button to specify a day as a “B” day.
  5. Once the day has been selected as an “A” or “B” day the programme will automatically jump to the next day.
  6. When the last day of the week is active, pressing +, -, or DAY will move back to the “A” days displayed with no selected (fl ashing) days (see image below).
  7. Repeat 2 to 6 until all selections have been made.
  8. When selections are completed, press the PROG button to move to event programming.

Danfoss TS715Si Electronic Single Channel Time Switch - AB Copy

Event Programming in AB mode

  1. Programme “A” day events using the + (time advance), – (time decrease), and NEXT (next period) buttons.
  2. Press the DAY button to change to programme the “B” days.
  3. Programme “B” day events using the + (time advance), – (time decrease), and NEXT (next period) buttons.

Service Interval Timer

The TS715 Si is fi tted with an installer setback service interval timer.
If this feature is required please contact our technical department.
Setting instructions for this gas safety feature are only available to bona fi de heating installers.

Wiring Conversions

(Applies only to 230 volt models)
Wiring conversions for other timeswitches which can be replaced with the Danfoss TS715-Si, refer to the second part of the table. If in any doubt, please contact our Technical Services Department before proceeding with the replacement.

DANFOSS RANDALL TS715-SiMAINS
Danfoss TS715Si Electronic Single Channel Time Switch - icon 3NL
Danfoss TS715Si Electronic Single Channel Time Switch - icon 3NL
The existing wallplate may be used when replacing the following, but the wiring link between L & COM terminals of wallplate.
ACL LS111, LS711, LP111 & LP711Danfoss TS715Si Electronic Single Channel Time Switch - icon 3NL
DRAYTON TEMPUS ONE & TEMPUS TWODanfoss TS715Si Electronic Single Channel Time Switch - icon 3NL
LANDIS & GYR RWB3Danfoss TS715Si Electronic Single Channel Time Switch - icon 3NL
LANDIS & GYR RWB30Danfoss TS715Si Electronic Single Channel Time Switch - icon 3NL
The TS75/TS15 wallplate must be used to replace the existing wallplate when repl mains voltage systems, fit wire link between terminal 1 & L of wallplate.
GRASSLIN 45, 45A, 45EDanfoss TS715Si Electronic Single Channel Time Switch - icon 321
HONEYWELL ST6100Danfoss TS715Si Electronic Single Channel Time Switch - icon 3NL
HORSTMANN 423 PEARL, EMERALD & TOPAZDanfoss TS715Si Electronic Single Channel Time Switch - icon 3NL
HORSTMANN KMK2A YMK2Danfoss TS715Si Electronic Single Channel Time Switch - icon 334
HORSTMANN 425 CORONETDanfoss TS715Si Electronic Single Channel Time Switch - icon 3NL
DANFOSS RANDALL 911Danfoss TS715Si Electronic Single Channel Time Switch - icon 3NL
DANFOSS RANDALL 103, 103E, 103E5 & 103E7Danfoss TS715Si Electronic Single Channel Time Switch - icon 356
RANDALL 3020Danfoss TS715Si Electronic Single Channel Time Switch - icon 31,76
DANFOSS RANDALL SET1Danfoss TS715Si Electronic Single Channel Time Switch - icon 3NL
RANDALL TSR2Danfoss TS715Si Electronic Single Channel Time Switch - icon 332
PEGLER SUNVIC SP20 & SP25/30Danfoss TS715Si Electronic Single Channel Time Switch - icon 3NL
POTTERTON MYSON EP4001Danfoss TS715Si Electronic Single Channel Time Switch - icon 3NL
LOADAn additional terminal block may be required where these disconnected leads (or pairs of leads) should be terminated
COMOFFSPAREON
1234ABCD
ust be reconnected as shown below. In addition, in mains voltage systems, fit wire
1243
1342
3142
2314
cing the following timeswitches. Wiring details are shown below. In addition, in
34
1234
314256
12
561423
5426
321
2435
5624
14567
34S5
524ABCD
DANFOSS RANDALL TS715-SiMAINS
Danfoss TS715Si Electronic Single Channel Time Switch - icon 3NL
Danfoss TS715Si Electronic Single Channel Time Switch - icon 3NL
The TS75/TS15 wallplate must be used to replace the existing wallplate when repl mains voltage systems, fit wire link between terminal 1 & L of wallplate.
SANGAMO M64,56
SANGAMO 410 FORM 84,53
SANGAMO S254 FORM 2, S408 FORM 5, S251 FORM 2Danfoss TS715Si Electronic Single Channel Time Switch - icon 3NL
SANGAMO S610 FORM 2, S611 FORM 2, S612 FORM 2, S408 FORM 4, S408 FORM 6, S253 FORM 2, S255 FORM 2Danfoss TS715Si Electronic Single Channel Time Switch - icon 3NMOTOR LIVE
SANGAMO S409 FORM 8Danfoss TS715Si Electronic Single Channel Time Switch - icon 33,N3,L
SANGAMO S263 FORM 2 SANGAMO S264 FORM 2Danfoss TS715Si Electronic Single Channel Time Switch - icon 3NL
SMITHS IND. MKI, MKIIDanfoss TS715Si Electronic Single Channel Time Switch - icon 3NL
SMITHS IND. CENTROLLER 30Danfoss TS715Si Electronic Single Channel Time Switch - icon 312
SMITHS IND. CENTROLLER 40Danfoss TS715Si Electronic Single Channel Time Switch - icon 312
SWITCHMASTERDanfoss TS715Si Electronic Single Channel Time Switch - icon 3NL
TOWERCHRON TCDanfoss TS715Si Electronic Single Channel Time Switch - icon 321
VENNER VENNERETTE MKIIADanfoss TS715Si Electronic Single Channel Time Switch - icon 3NL
VENNER VENNERETTE MKIVADanfoss TS715Si Electronic Single Channel Time Switch - icon 323
VENNER VENOTIME
(WITH NEON INDICATING CIRCUIT ON)
Danfoss TS715Si Electronic Single Channel Time Switch - icon 3NL
VENNER VENOTIME
(WITH NEON INDICATING POWER ON)
Danfoss TS715Si Electronic Single Channel Time Switch - icon 3NL
VENNER VENNERON, VENNERON PDanfoss TS715Si Electronic Single Channel Time Switch - icon 332
LOADAn additional terminal block may be required where these disconnected leadss (or pairs of leads) should be terminated
COMOFFSPAREON
1234ABCD
cing the following timeswitches. Wiring details are shown below. In addition, in
32718
26178
LOAD
SWITCH LIVE 

LOAD
612
OFFON
P2P1P3
34,56
34,5
4213
437891011
LINELOAD
41
123
213
14

Danfoss logo

Danfoss Ltd.
Ampthill Road
Bedford MK42 9ER
Part No. 38163v01s7-06 01/11
Tel: 01234 364621
Fax: 01234 219705
Email: ukheating@danfoss.com
Website: www.heating.danfoss.co.uk

Documents / Resources

Danfoss TS715Si Electronic Single Channel Time Switch [pdf] Installation Guide
TS715Si Electronic Single Channel Time Switch, TS715Si, Electronic Single Channel Time Switch, Single Channel Time Switch, Channel Time Switch, Time Switch, Switch
Danfoss TS715Si Electronic Single Channel Time Switch [pdf] User Guide
TS715Si Electronic Single Channel Time Switch, TS715Si, Electronic Single Channel Time Switch, Single Channel Time Switch, Channel Time Switch, Time Switch

References

Leave a comment

Your email address will not be published. Required fields are marked *