Danfoss AS Solenoid Coil
INSTRUCTIONS
Type of control | 1 | ||
Safety classification | Class I | ||
Ambient temperature | 6 W V AC NC valve 7 W V AC NC valve 14 W V DC | -40 – 60 °C (-40 – 140 °F) -40 – 50 °C (-40 – 122 °F) -40 – 60 °C (-40 – 140 °F) | |
Humidity | 0 – 100% R.H. (0 – 97% R.H. non-condensation condition if IP level is below IPX5/NEMA X4) | ||
Voltage variation | V AC V DC | -15% – 10% ±10% | |
Ball pressure test | 200 °C (392 °F) | ||
Impulse withstand voltage | Cable Spade Plug Plug | 4.0 kV at altitude <4000 m (13123 ft) 4.0 kV at altitude <4000 m (13123 ft) 4.0 kV at altitude <2000 m (6561 ft) 3.1 kV 2000 m<altitude<4000 m (6561<altitude<13123 ft) | |
Enclosure rate IPXX Pollution degree PDX | Cable Plug Spades | IP67 IP65 IP00 | PD4 PD3 PD3 |
Installation | Integrated control Incorporated control Independently mounted control | ||
Suitable cable and conductor size for plug | ø6.6 – ø11 mm (ø0.26 – ø0.43 in) 0.75 – 1.5 mm² (21 – 15 AWG flexible cord) | ||
Number of mating for plug | 10 times | ||
Cable size Cable conductor size | ø6.6 mm (ø0.26 in) 3 x 0.75 mm² (3 x 0.001 in2) Installation and handling for cable: > 5 °C (41 °F) | ||
– Only qualified personnel is allowed to install or maintain this product – Disconnect the power when dismounting the coil – Avoid direct exposure to alkaline conditions, use in neutral conditions is recommended – Ensure that the O-ring is in place on the valve -If the coil is used as independently mounted control, the end-user shall use a plastic cable gland with strain relief Special note for R290: The 9 mm coil (IP65/67) is validated in accordance to ISO 5149, IEC 60335 (ref. IEC/EN 60079- 15). Ignition risk is evaluated in accordance to ISO 5149 and IEC 60335 (ref. IEC/EN 60079-15). Please make sure that there is no spark, arc on the spade connection during the application. Always Install a fuse ahead of the coil: rated current: two times of rated current, time lag: medium, to avoid short circuit. The coil used in an area of not more than pollution degree 2.
Follow the installation guide to mount the coil correctly, and apply o-ring for sealing to prevent moisture penetrating inside the coil. Safety note: The 9 mm coil (IP65/67) can be applied on systems with R290 as the working fluid. For countries where safety standards are not an indispensable part of the safety system Danfoss recommends the installer gets a third party approval of any system containing flammable refrigerant. Please follow specific selection criteria stated in the datasheet for these particular refrigerants. Note that 9 mm coil (IP65/67) has NOT been verified ATEX or IECEx or IEC 60079 series zone 2 compliant. The product is only validated for systems in compliance with ISO5149, IEC 60335 (ref. IEC/EN 60079-15). It is the responsibility of the user to verify such compliance. Improper use can cause explosion, fire, leakage potentially causing death, personal injury, or damage to property |