Danfoss Additional Wood Fibre Insulation Installation Guide

Danfoss Additional Wood Fibre Insulation - front page

Danfoss Additional Wood Fibre Insulation - installation steps
Fig. 1: The floor base must be dry and even and load bearing (tolerance maximum 3 mm/m).

Danfoss Additional Wood Fibre Insulation - installation steps
Fig. 2: Attach SpeedUp Eco perimeter insulation on the wall. Avoid overlapping the ends. ¹

Danfoss Additional Wood Fibre Insulation - installation steps
Fig. 3: Fold perimeter insulation to fit into corners.

Danfoss Additional Wood Fibre Insulation - installation steps
Fig. 4: Lay insulation panels in a staggered pattern, cross-laid compared to direction of SpeedUp Eco heat panels.

Danfoss Additional Wood Fibre Insulation - installation steps
Fig. 5: Use a hand circular saw to cut to correct size. Begin next row with the cut off piece. In thresholds only use whole panels.

Danfoss Additional Wood Fibre Insulation - installation steps
Fig. 6: Butt panels tightly to one another. Make sure the panels are level.

Danfoss Additional Wood Fibre Insulation - installation steps
Fig. 7: Always cross-lay the second layer of insulation panels. The final layer of insulation must be cross-layed to the SpeedUp heat panels.

Danfoss Additional Wood Fibre Insulation - installation steps
Fig. 8: Enclose pipe section with panels (max. width 30 cm according to BEB/ZDB Information leaflet), fix and fill up with bonded compound up to level of insulation.

Danfoss Additional Wood Fibre Insulation - installation steps
Fig. 9: Pipe sections with insulated pipes and width from 20 cm must be covered with a 1 mm aluminium plate and with 5 cm overlap. ²

Danfoss Additional Wood Fibre Insulation - installation steps
Fig. 10: Protect insulation from frequent pedestrian traffic to avoid damage.

¹ Additional insulation ≥ 5 cm is laid without perimeter insulation. Position the perimeter insulation afterwards on the additional insulation.

² For light floor constructions (e.g. when laying laminate/parquet directly on the heat panel and all strongboard constructions) pipe channels – in the additional insulation – with a width of more than 10cm must be covered with a metal plate (min. 1 mm). If the pipe channels have a width of more than 15 cm a special loadbaring plate (min. 18 mm OSB or similar) must be used.

Danfoss A/S
Heating Solutions
Haarupvaenget 11
8600 Silkeborg
Denmark
Phone:+45 7488 8000
Fax: +45 7488 8100
Email: ComfortControlsInternet@danfoss.com
www.heating.danfoss.com

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

VICSE302

Produced by Danfoss Heating Solutions © 11/2010

Documents / Resources

Danfoss Additional Wood Fibre Insulation [pdf] Installation Guide
AN002386456741en-010301, VICSE302, Additional Wood Fibre Insulation, Wood Fibre Insulation, Fibre Insulation, Insulation

References

Leave a comment

Your email address will not be published. Required fields are marked *