080G5040 IPS 8 Extension Module
“
Product Information
Specifications
- Model: IPS 8 extension module
- Type: MCX08M2
- Number of Digital Outputs: 8
- Total Current Load Limit: 32 A
- Relay Type: 8 relays
- Insulation: Functional insulation between relay, reinforced
insulation between relays and extra-low voltage parts
Product Usage Instructions
Installation
- Connect the IPS 8 extension module via CANbus back to IPS with
MCX15B2. - Ensure proper connection of field connected solenoid coils for
purge points powered from IPS main E-panel. - Hardwire the IPS 8 extension module to field-connected field
coils using CANBus.
Operation
- Utilize the LCD display to monitor and control the 8 purge
points. - Refer to the main screen for serial settings and configuration
details.
Maintenance
- Regularly check the connections and ensure proper functioning
of the relays. - Keep the product clean and free from dust or debris.
FAQ
How to reconfigure Digital output?
To reconfigure a Digital Output such as DO23 as valve 16, follow
these steps:
- Access the settings menu on the IPS 8 with MCX15B2
controller. - Locate the specific Digital Output you wish to reconfigure (in
this case DO23). - Select the desired function for the output, in this case, set
it as valve 16. - Save the changes and ensure proper operation after
reconfiguration.
“`
080R9501 110
080R9501
Installation guide
IPS 8 extension module | 080G5040
Type MCX08M2
Introduction The IPS 8 extension module is always connected via CANbus, back to IPS with MCX15B2. The IPS 8 extension module includes 8 Digital Output which then give up to 8 additional Purge Points.
080R9501 AN508522055668en-000101
Reference: For details please refer data sheet Programmable controller, 8 relays, type MCX08M2 Applications
More info
IPS 8 with MCX15B2 controller Accessory package allowing extra Purge Points
IPS 8 with MCX15B2 controller – Field connected solenoid coils for purge points is powered from IPS main E-panel
Accessory package
Includes – MCX08M2 w/SW IPS 8 extension module
Hardwired to field connected field coils
CANBus
Hardwired to field connected field coils
8 purge points
Dimension IPS 8
8 purge points LCD display
140 © Danfoss | Climate Solutions | 2024.12
63 AN508522055668en-000101 | 1
084H5001, IPS 8, CE, 230 V AC, 1ph, 50Hz 084H5002, IPS 8, 230 V AC, 1ph, 60Hz
Bottom board
+24 V AC/DC
CAN H CAN L CAN GND
MCX15B2
IPS 8, Air Purger
IPS 8 Control box
CAN bus
45 6 8 XT4 XT4 XT4 XT4
CAN H CAN L CAN GND
BR
WH GN SCH
29.5 29.6 29.7 29.8 XM4 XM4 XM4 XM4
084H5003, IPS 8, UL 230 V AC, 1ph, 60Hz
MCX08M2 – BOTTOM
PP9 EV
PP10 EV
PP11 EV
PP12 EV
PP13 EV
PP14 EV
PP15 EV
PP16 EV
Danfoss 80G8036B
Connectors Power supply connector CAN connector Digital output 1-8 connector 2 | AN508522055668en-000101
Type 2 way screw plug-in connector type 4 way screw plug-in connector type 4 way screw plug-in connector type
Dimensions
· pitch 5 mm · section cable 0.22.5 mm
· pitch 5 mm · section cable 0.22.5 mm
· pitch 5 mm · section cable 0.22.5 mm
© Danfoss | Climate Solutions | 2024.12
General features
Features
Power supply
Plastic housing
Ball test Operating conditions Storage conditions Integration Index of protection Period of electric stress across insulat- ing parts Resistance to heat and fire Immunity against voltage surges Software class and structure
Description 2060 V DC and 24 V AC ± 15% 50/60 Hz SELV Maximum power consumption: 10 W, 17 V A Insulation between power supply and the extra-low voltage: functional DIN rail mounting complying with EN 60715 Self extinguishing V0 according to IEC 60695-11-10 and glowing / hot wire test at 960 °C according to IEC 60695-2-12 125 °C according to IEC 60730-1 Leakage current: 250 V according to IEC 60112 CE: -20T60 / UL: 0T55, 90% RH non-condensing -30T80, 90% RH non-condensing In Class I and / or II appliances IP40 only on the front cover
Long
Category D
Category II
Class A
Digital outputs
Type Num Specifications
Relay 8
Insulation between relay: functional Insulation between relays and the extra-low voltage parts: reinforced Total current load limit: 32 A
C1-NO1, C2-NO2 High inrush current (80 A20 ms) normally open contact relays 16 A Characteristics of each relay:
· 10 A 250 V AC for resistive loads – 100.000 cycles · 3.5 A 230 V AC for inductive loads – 230.000 cycles with cos(phi) = 0.5
C5-NO5, C6-NO6 Normally open contact relays 8 A Characteristics of each relay:
· 6 A 250 V AC for resistive loads – 100.000 cycles · 4 A 250 V AC for inductive loads – 100.000 cycles with cos(phi) = 0.6 Option for code 080G0314: · SPST SSR type · 0.5 A 250 V AC resistive load (115 W)
C3-NO3-NC3, C4-NO4-NC4, C7-NO7-NC7, C8-NO8-NC8 Changeover contacts relay 8 A Characteristics of each relay:
· 6 A 250 V AC for resistive loads – 100.000 cycles · 4 A 250 V AC for inductive loads – 100.000 cycles with cos(phi) = 0.6
© Danfoss | Climate Solutions | 2024.12
AN508522055668en-000101 | 3
IPS 8 extension module – Main screen
Serial setting: ID: 125 – expansion module address 125 ComS: 34800 – expansion module baud rate 34800 IPSB ID: 1- main controller address 1
IPS 8 with MCX15B2 controller – settings
All settings are configured in the main controller A. How to activate Expansion module? «Main Menu» «Start» «Main switch OFF» «Main menu» «Login» «Password 200» «General» «Expansion settings» «Yes» «Main Menu» «Start» «Main switch OFF»
B. How to change the number of purge points? «Main Menu» «Start» «Main switch OFF» «Main menu» «Login» «Password 200» «Parameters» «Unit config» «Valve settings» «Max PP …» «Main Menu» «Start» «Main switch OFF»
C. How to reconfigure Digital output? For example: DO23 as valve 16.
«Main Menu» «Start» «Main switch OFF» «Main menu» «Login» «Password 200» «Input/output «I/O Configuration» «Valve settings» «Digital output «Digital output 23» «Valve 16» «Main Menu» «Start» «Main switch OFF»
© Danfoss | Climate Solutions | 2024.12
AN508522055668en-000101 | 4
Documents / Resources
![]() | Danfoss 080G5040 IPS 8 Extension Module [pdf] Installation Guide 080G5040 IPS 8 Extension Module, 080G5040, IPS 8 Extension Module, Extension Module, Module |