Tenmars TM-902

Tenmars TM-902 LAN Cable Tester User Manual

Model: TM-902

1. Introduktion

The Tenmars TM-902 is a portable, professional test device designed for verifying and troubleshooting twisted-pair LAN cables. It provides comprehensive analysis of cable connections, identifying various faults quickly and efficiently.

This manual provides detailed instructions for the proper use and maintenance of your TM-902 LAN Cable Tester.

2. Pakkens indhold

Før du bruger enheden, skal du kontrollere pakkens indhold for at sikre, at alle dele er til stede:

  • 1 x TM-902 Main Unit
  • 1 x CAT5 STP Cable
  • 1 x Remote ID Unit
  • 6 x 1.5V AAA batterier
  • 1 x bæretaske
  • 1 x engelsk brugervejledning
Tenmars TM-902 LAN Cable Tester package contents including main unit, remote ID, cables, batteries, and carrying case.

Figure 2.1: Complete package contents of the Tenmars TM-902 LAN Cable Tester.

3. Opsætning

3.1 Batteriinstallation

  1. Locate the battery compartment on the back of the TM-902 main unit.
  2. Åbn batterirummets dæksel.
  3. Isæt 6 x 1.5V AAA-batterier, og sørg for korrekt polaritet (+/-).
  4. Luk batterirummets dæksel forsvarligt.

3.2 Tilslutning af kabler til test

The TM-902 supports testing of UTP and STP LAN cables with RJ-45 connectors. It also includes a remote ID unit for testing installed cables.

Nærbillede view of the RJ-45 and F-type coaxial ports on the Tenmars TM-902 LAN Cable Tester.

Figure 3.1: RJ-45 and F-type coaxial ports on the main unit.

  1. Connect one end of the LAN cable to be tested into the RJ-45 port on the main TM-902 unit.
  2. For remote testing, connect the other end of the LAN cable to the Remote ID unit. The device supports up to 8 different remote ID identifiers, though one remote ID unit is included.
  3. For direct testing of shorter cables, both ends can be connected to the main unit if applicable (though typically one end goes to the main unit and the other to the remote unit or a loopback).
Various cables and two remote ID locators for the Tenmars TM-902 LAN Cable Tester.

Figure 3.2: Included cables and remote ID locators.

4. Betjeningsvejledning

The TM-902 features a backlit LCD screen that simultaneously displays wire-map, open circuits, short circuits, miswires, split pairs, and remote end ID numbers graphically.

The Tenmars TM-902 LAN Cable Tester main unit with its LCD screen and control buttons.

Figure 4.1: Tenmars TM-902 main unit with LCD display.

4.1 Udførelse af en kabeltest

  1. Ensure the batteries are installed and the cable is properly connected to the main unit and remote ID (if applicable).
  2. Press the "TEST" button to initiate the cable test.
  3. Observe the backlit LCD screen for test results. The screen will graphically display the wire-map and any detected faults.
  4. The remote ID number, if connected, will also be shown on the LCD screen.

4.2 Understanding Test Results

  • Open Circuit (Open): An open circuit indicates that a wire pair is not connected at both ends. One or more conductors in the cable do not complete the circuit, preventing the signal from reaching its destination. The TM-902 clearly shows which pins are open on the graphic display, helping to identify the problematic wire pair.
  • Short Circuit (Short): A short circuit occurs when two wires that should not be in contact directly touch each other. This can hinder data transmission and potentially damage connected devices. The TM-902 immediately identifies shorted pins and provides an alert on the screen.
  • Miswire: A miswire is a wiring error where the wire ends are connected in the wrong sequence. For example, if pin 3 connects to pin 5 instead of pin 6 at the far end, it's a miswire. Even if a physical connection exists, signals do not reach the correct line, degrading network performance. The TM-902 graphically displays mismatched connections by comparing each pin number.
  • Split Pair: A split pair is a wiring error where wire ends are connected to the correct pins but are grouped into incorrect pairs. Even if electrical continuity is maintained, this error causes interference (crosstalk) in data transmission and leads to network connection issues. The TM-902 can detect split pair errors in cables of at least 5 meters and notifies the user with a "SPLIT" warning. This type of error often results from incorrect pairing of wires during cable assembly and is not visible externally.

Note: A minimum cable length of 5 meters is required for split pair detection.

5. Vedligeholdelse

To ensure the longevity and accurate performance of your Tenmars TM-902 LAN Cable Tester, follow these maintenance guidelines:

  • Rensning: Brug en blød, tør klud til at rengøre enheden. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
  • Opbevaring: Når enheden ikke er i brug, skal den opbevares i dens bæretaske på et køligt, tørt sted, væk fra direkte sollys og ekstreme temperaturer.
  • Udskiftning af batteri: Replace batteries promptly when the low battery indicator appears on the screen to ensure accurate readings and prevent battery leakage. Remove batteries if the device will not be used for an extended period.
  • Håndteres med forsigtighed: Undgå at tabe enheden eller udsætte den for kraftige stød, da dette kan beskadige de interne komponenter.
Tenmars TM-902 LAN Cable Tester with its carrying case, shown on a table.

Figure 5.1: Tenmars TM-902 with its protective carrying case.

6. Fejlfinding

This section provides guidance for common issues encountered during the use of the TM-902 LAN Cable Tester.

  • Enheden tændes ikke:
    • Kontroller, om batterierne er installeret korrekt med den rigtige polaritet.
    • Replace old or depleted batteries with new 1.5V AAA batteries.
  • Inaccurate test results or no display:
    • Ensure cable connectors (RJ-45) are fully inserted into the ports on both the main unit and the remote ID unit.
    • Verify that the cable itself is not visibly damaged.
    • Clean the RJ-45 ports if there is any visible dust or debris.
  • "SPLIT" error on short cables:
    • The TM-902 requires a minimum cable length of 5 meters to accurately detect split pair errors. Test longer cables for this specific fault.
  • Remote ID not detected:
    • Ensure the remote ID unit is properly connected to the far end of the cable.
    • Check if the remote ID unit itself is functioning (though it's a passive device, ensure its connector is clean).

7. Specifikationer

Feature Specifikation
Tested Cable Types UTP, STP
Wiremap Test Detects open circuit, short circuit, miswire, and split pairs.
Cable Category Types CAT5, CAT6
Teststik Shielded 8-pin modular jack (RJ-45)
Length Test Range Op til 255 meter
Length Test Resolution 0.1 meter
Length Test Unit Meter
Længdetestnøjagtighed ± 10% + 1.0 meter
Vise 58mm x 45mm, Backlit LCD
Driftstemperatur og luftfugtighed 5℃ to 40℃, below 80% RH
Opbevaringstemperatur og fugtighed -10℃ to 60℃, below 70% RH
Strømkilde 6 x 1.5V AAA batterier
Dimensioner 156 x 73 x 35 mm
Vægt 170 gram

8. Sikkerhedsoplysninger

Læs og forstå venligst følgende sikkerhedsforanstaltninger, før du bruger enheden:

  • Forsøg ikke at åbne eller ændre enheden. Overlad al service til kvalificeret personale.
  • Udsæt ikke enheden for fugt eller ekstreme temperaturer.
  • Ensure correct battery polarity during installation. Remove batteries if the device is not used for extended periods to prevent leakage.
  • This device is designed for testing LAN cables. Do not connect it to live electrical circuits or power outlets.

© 2023 Tenmars. Alle rettigheder forbeholdes.