AIDA Imaging HD-NDI-CUBE

AIDA HD-NDI-Cube Full HD NDI|HX IP POV Camera User Manual

Comprehensive instructions for the setup, operation, and maintenance of your AIDA HD-NDI-Cube camera.

Vigtige sikkerhedsoplysninger

  • Læs alle instruktioner omhyggeligt, før du betjener enheden.
  • Gem denne vejledning til fremtidig reference.
  • Do not expose the camera to moisture or extreme temperatures.
  • Brug kun den strømadapter, der er angivet til denne enhed.
  • Forsøg ikke at skille kameraet ad eller ændre det. Overlad al service til kvalificeret personale.
  • Ensure proper ventilation around the camera during operation.

Pakkens indhold

Bekræft at alle varer er til stede i pakken:

  • AIDA HD-NDI-Cube Camera
  • Power Adapter (typically included for operation)
  • Dokumentation (denne manual)
  • Note: The product listing generically mentions "item" for 'whats_in_the_box'. This manual assumes the camera unit and necessary power supply are included.

Opsætning

1. Fysisk installation

The AIDA HD-NDI-Cube camera features versatile mounting options for various applications.

  • Identify a suitable location for the camera, ensuring it is stable and has clear line of sight for its intended use.
  • Utilize the top and bottom tripod mounts for secure attachment to tripods, stands, or other mounting hardware.
  • Ensure adequate space for cable connections and ventilation.
AIDA HD-NDI-Cube camera side view

Figur 1: Side view of the AIDA HD-NDI-Cube camera, showing its compact form factor.

2. Forbindelse

Connect the camera to power and network for operation.

  1. Strømtilslutning: Connect the provided 12V DC power adapter to the "12VDC" port on the rear of the camera. Plug the adapter into a suitable power outlet. The power indicator LED should illuminate.
  2. Netværks forbindelse: Connect an Ethernet cable from your network switch or router to the "IP/NDI|HX" Ethernet port on the rear of the camera. This connection is essential for NDI|HX video streaming and IP control.
  3. Installation af objektiv: If a C/CS mount lens is not pre-installed, carefully attach your desired C/CS mount lens to the camera body. Ensure it is securely fastened.
AIDA HD-NDI-Cube camera rear panel with ports

Figure 2: Rear panel of the AIDA HD-NDI-Cube, showing the IP/NDI|HX Ethernet port and 12VDC power input.

AIDA HD-NDI-Cube camera front and side view med linse

Figur 3: Forside og side view of the AIDA HD-NDI-Cube camera, highlighting the C/CS lens mount and SVC port.

Betjeningsvejledning

1. Første opstart

Once connected to power and network, the camera will initiate its startup sequence. The power indicator LED will confirm the device is on.

2. Adgang til Web UI

The camera features an accessible web user interface (UI) for configuration and control.

  1. Sørg for, at din computer er på samme netværk som kameraet.
  2. Use a network scanner tool (e.g., NewTek NDI Tools) to discover the camera's IP address on your network.
  3. Åbn a web browser and enter the camera's IP address into the address bar.
  4. Log in using the default credentials (refer to the camera's specific documentation for default username/password, typically "admin" / "admin" or similar).
  5. Fra web UI, you can adjust image parameters, network settings, and stream directly to social media platforms.

3. NDI|HX Video Streaming

The AIDA HD-NDI-Cube outputs Full HD 1080p60 NDI|HX video, compatible with NDI-enabled software and hardware.

  • Once the camera is connected to the network, it should be discoverable by NDI-compatible applications (e.g., OBS Studio, vMix, TriCaster).
  • In your NDI receiving software, select the AIDA HD-NDI-Cube as an NDI source.
  • Adjust video settings within your software or the camera's web UI as needed for optimal performance.

Opretholdelse

1. Rensning

  • Ensure the camera is powered off and disconnected from all sources before cleaning.
  • Use a soft, dry cloth to wipe the camera body. Do not use liquid cleaners or aerosols.
  • Brug en specialklud og -opløsning til linsen for at undgå ridser.

2. Firmwareopdateringer

Periodically check the AIDA Imaging official website for available firmware updates. Firmware updates can improve performance, add features, and resolve issues.

  • Download the latest firmware from the manufacturer's support page.
  • Follow the specific instructions provided with the firmware update package for installation via the camera's web UI.
  • Forsigtighed: Do not power off the camera during a firmware update, as this may cause irreversible damage.

Fejlfinding

No NDI Signal Detected

  • Netværks forbindelse: Ensure the Ethernet cable is securely connected to both the camera and the network switch/router. Verify network activity lights on the camera's Ethernet port.
  • IP-adressering: Confirm that the camera and the receiving computer are on the same IP subnet. Incorrect subnet masks can prevent NDI discovery. Access the camera's web UI to verify or adjust network settings. A firmware update may be required to resolve specific IP addressing issues.
  • Software Permissions: If using software like OBS Studio on Windows, ensure the application is run with administrator privileges. Some NDI implementations require elevated permissions to access network streams.
  • Firewall-indstillinger: Check firewall settings on your computer and network to ensure NDI traffic is not being blocked.

Intermitterende signaltab

  • Netværksstabilitet: Verify the stability and bandwidth of your network. NDI|HX requires a stable network connection.
  • Kabelintegritet: Inspect Ethernet cables for damage. Try replacing cables if issues persist.
  • Firmware: Ensure the camera's firmware is up to date. Older firmware versions may have known stability issues.

Dårlig billedkvalitet

  • Linsefokus: Adjust the focus of the C/CS mount lens.
  • Lysforhold: Ensure adequate and appropriate lighting for your scene.
  • Web Brugergrænsefladeindstillinger: Få adgang til kameraets web UI to adjust image parameters such as exposure, white balance, and color temperature.
  • Digital zoom: Avoid excessive digital zoom, as it can degrade image quality on 1080p cameras. Consider variable focus lens replacements for optical zoom capabilities.

Tekniske specifikationer

FeatureSpecifikation
MærkeAIDA billedbehandling
ModelnummerHD-NDI-CUBE
Sensortype1/3'' Progressive Scan CMOS
Videooptagelsesopløsning1080p (Full HD)
Effektiv videoopløsning2.07 MP
ForbindelsesteknologiEthernet (NDI|HX)
LinsemonteringC/CS montering
Minimum brændvidde1 Millimeter (Lens dependent)
Maksimal brændvidde4 Millimeters (Lens dependent)
Maksimal blænde3 f (Lens dependent)
Fokus TypeFixed Focus (Lens dependent)
FormfaktorKompakt
FarveSort
FunktionerLow Light Capability
BilledstabiliseringIngen
VandmodstandsniveauIkke vandafvisende
Understøttet lydformatPCM, MP3, AAC
VideooptagelsesformatASF
Understøttet billedformatJPEG
Billedformatforhold16:9
HvidbalanceindstillingerAuto
EksponeringskontroltypeProgram (P)
OptagetilstandeManual, Automatic, Program (P)
Kompatible enhederPC eller Mac
UPC686091739809

Garanti og support

Garantioplysninger

AIDA Imaging products are typically covered by a manufacturer's warranty. For specific warranty terms and conditions, including duration and coverage details, please refer to the warranty card included with your product or visit the official AIDA Imaging webwebsted.

Gem dit købsbevis for garantikrav.

Kundesupport

For technical assistance, troubleshooting beyond this manual, or service inquiries, please contact AIDA Imaging customer support.

  • Visit the official AIDA Imaging webwebsted for supportressourcer, ofte stillede spørgsmål og kontaktoplysninger.
  • Have your product model number (HD-NDI-CUBE) and serial number ready when contacting support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.