1. Produktet er slutview
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Ingersoll Rand Electric Stationary Air Compressor, Model 7100E15-P. This Type-30 compressor is designed for demanding applications, offering reliable performance for various industrial and commercial uses.

Figur 1: Ingersoll Rand Electric Stationary Air Compressor Model 7100E15-P. This image displays the complete compressor unit, including the motor, pump, and horizontal air receiver tank.
Nøglefunktioner i denne model inkluderer:
- 15 HP motor, 460 Volts, 3 Phase electrical requirement.
- 120 Gallon Horizontal Air Receiver Tank.
- Air-cooled after-cooler for improved air quality.
- Electric drain valve for automatic condensate removal.
- Low oil protection switch to prevent damage from insufficient lubrication.
- Delivers 51 CFM at 90 PSI, with a maximum pressure of 175 PSI.
2. Sikkerhedsoplysninger
Always read and understand all safety warnings and instructions before installing, operating, or performing maintenance on the air compressor. Failure to follow these instructions can result in serious injury or death.
- Ensure proper electrical grounding and wiring by a qualified electrician.
- Brug ikke kompressoren i eksplosive atmosfærer.
- Brug passende personlige værnemidler (PPE), herunder øjen- og høreværn.
- Depressurize the system before performing any maintenance or service.
- Hold børn og uautoriseret personale væk fra den fungerende kompressor.
3. Installation og opsætning
Proper installation is crucial for the performance and longevity of your air compressor. This unit is heavy (approximately 1297 pounds) and requires appropriate lifting equipment for safe placement.
3.1 Valg af sted
- Install the compressor on a level, solid surface capable of supporting its weight.
- Ensure adequate ventilation to prevent overheating. Maintain clear space around the unit for airflow and service access.
- Locate the compressor in a clean, dry area, away from dust, moisture, and corrosive vapors.
3.2 Elektrisk tilslutning
This compressor requires a 460 Volts, 3 Phase electrical supply. All electrical connections must be performed by a qualified and licensed electrician in accordance with local and national electrical codes.
- Verify the power supply matches the compressor's voltage- og fasekrav.
- Ensure proper circuit protection (fuses/breakers) is installed.
- Confirm correct motor rotation after initial power-up.
3.3 Air Line Connection
- Connect the compressor to your air distribution system using appropriate piping and fittings.
- Install a shut-off valve close to the compressor for isolation during maintenance.
- Consider installing a filter/regulator/lubricator (FRL) unit downstream for optimal tool performance and air quality.
4. Betjeningsvejledning
4.1 Tjekliste før brug
- Check the oil level in the compressor pump. Add oil if necessary (refer to maintenance section for oil specifications).
- Sørg for, at alle forbindelser er sikre og fri for lækager.
- Verify the power supply is connected and the main disconnect switch is in the "OFF" position.
4.2 Start af kompressoren
- Turn the main power disconnect switch to the "ON" position.
- Locate the compressor's control panel and press the "START" button.
- Allow the compressor to build pressure. The pressure switch will automatically shut off the motor when the maximum set pressure (175 PSI) is reached.
4.3 Shutting Down the Compressor
- Press the "STOP" button on the control panel.
- Turn the main power disconnect switch to the "OFF" position.
- Drain any accumulated condensate from the air receiver tank using the electric drain valve or manual drain valve if applicable.
5. Vedligeholdelse
Regular maintenance is essential for extending the life and ensuring the reliable operation of your Ingersoll Rand air compressor. Always disconnect power before performing any maintenance.

Figur 2: Internal components of the Ingersoll Rand compressor pump. This diagram illustrates key design features such as the two-stage design, radial fins for cooling, one-piece connecting rod, splash lubrication, and 100% cast iron construction, all contributing to the pump's durability and performance.
5.1 Daglige kontroller
- Check oil level and add if necessary. The low oil protection switch will prevent operation if the level is too low.
- Drain condensate from the air receiver tank. The electric drain valve automates this process, but manual checks are recommended.
- Inspect for unusual noises, vibrations, or leaks.
5.2 Weekly/Monthly Checks
- Clean air intake filter. Replace if heavily soiled or damaged.
- Inspect drive belts for tension and wear. Adjust or replace as needed.
- Tjek alle fastgørelsesanordninger for tæthed.
5.3 Quarterly/Annual Checks
- Change compressor oil. Use only Ingersoll Rand approved compressor oil.
- Inspect safety relief valve for proper operation.
- Have a qualified technician inspect the air receiver tank for corrosion or damage.
For extended pump warranty from 1 year to 2 years, purchase and use the 2yr Warranty Start Up Kit #6131992 (sold separately). This kit typically includes the necessary oil and filters for initial maintenance.
6. Fejlfinding
This section provides guidance for common issues. For problems not listed or if solutions do not resolve the issue, contact authorized service personnel.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Kompressoren starter ikke | No power, tripped breaker, low oil level, faulty pressure switch. | Check power supply, reset breaker, check/add oil, inspect pressure switch. |
| Kompressoren kører kontinuerligt | Air leak, faulty pressure switch, clogged air filter. | Check for leaks, inspect/replace pressure switch, clean/replace air filter. |
| Lavt lufttryk | Air leak, worn pump components, clogged air filter, improper pressure switch setting. | Check for leaks, inspect pump, clean/replace air filter, adjust pressure switch. |
| Overdreven støj eller vibrationer | Loose components, worn bearings, unbalanced motor/pump. | Inspect and tighten components, contact service for bearing/motor issues. |
7. Specifikationer
| Specifikation | Værdi |
|---|---|
| Mærke | Ingersoll Rand |
| Modelnavn | Ingersoll Rand Air Compressor |
| Varemodelnummer | 45466232 |
| Motor hestekræfter | 15 HK |
| Voltage | 460 volt, 3-faset |
| Strømkilde | Elektrisk med ledning |
| Luftmængde kapacitet | 50 CFM (at 175 PSI), 51 CFM (at 90 PSI) |
| Maksimalt tryk | 175 PSI |
| Tank størrelse | 120 gallon vandret |
| Varens vægt | 1297 pund |
| Pakkedimensioner | 83 x 65 x 36 tommer |
| Farve | Grå |
| UPC | 678384662321 |
8. Garantioplysninger
The reciprocating pump typically comes with a 1-year warranty. This warranty can be extended to 2 years with the purchase and use of the 2yr Warranty Start Up Kit #6131992 (solgt separat).
For specific warranty details and claims, please contact Ingersoll Rand directly or refer to the warranty documentation included with your product. The general warranty description states: "Call vendor for warranty."
9. Kundesupport
For technical assistance, parts, or service inquiries, please contact Ingersoll Rand customer support. You can also visit the official Ingersoll Rand store for additional product information and resources.
Official Ingersoll Rand Store: Visit the Ingersoll Rand Store on Amazon