1. Úvod
This manual provides essential instructions for the safe and efficient installation, operation, and maintenance of the PHILIPS Advance e-Vision IMH-100-D-BLS 100 Watt Pulse Start Metal Halide Ballast. Please read this manual thoroughly before proceeding with any installation or operation.
2. Bezpečnostní informace
VAROVÁNÍ: Nebezpečí úrazu elektrickým proudem. Před servisem odpojte napájení.
- Always disconnect line voltage before installing, replacing, or servicing the ballast.
- Power must be reset after replacing the lamp.
- Ensure proper grounding by connecting the green wire or through the ballast enclosure.
- This ballast is suitable for recessed use.
- Do not install insulation above or within 3 inches of the ballast sides to prevent overheating.
- Use only 4.0kV pulse rated lampholders for screw base lamps.
- Do not connect the RED or BLUE lead to neutral.
- Instalaci by měl provést kvalifikovaný elektrikář v souladu s národními a místními elektrotechnickými předpisy.
3. Konec produktuview
The PHILIPS Advance e-Vision IMH-100-D-BLS is an electronic ballast designed for (1) 100W Metal Halide lamp. It features IntelliVolt® technology, allowing operation on 120V to 277V, 50/60Hz input. Key features include Lamp End-of-life (EOL) Detection, high power factor, and thermal protection.

Obrázek 1: PHILIPS Advance e-Vision IMH-100-D-BLS Ballast. This image displays the ballast unit with its label, detailing electrical specifications, safety warnings, and basic wiring diagrams for 100W lamp operace.
4. Nastavení a instalace
Follow these steps for proper installation of the ballast:
- Odpojení napájení: Ensure that the main power supply to the circuit is completely disconnected before beginning installation.
- Montáž: Securely mount the ballast in a suitable location, ensuring adequate ventilation. Maintain a minimum clearance of 3 inches from any insulation.
- Připojení kabeláže: Refer to the wiring diagrams below for correct connections.
- Connect the RED lead to the center terminal of the lamp (for screw base lamps).
- Do not connect the RED or BLUE lead to neutral.
- Ensure proper grounding using the green wire or by grounding through the ballast enclosure.
- Lamp Instalace: Install a 100W Metal Halide lamp (ANSI M90 or M140) into a 4.0kV pulse rated lampdržák.
- Obnovení napájení: Once all connections are secure and verified, restore power to the circuit.
Schémata zapojení

Obrázek 2: General wiring diagram for 100W lamp operation, showing connections for input power and lamp output. Note the grounding options.

Obrázek 3: Detailed diagram illustrating the connection of the red lead to the center terminal of a screw base lamp, and the importance of not connecting red or blue leads to neutral.
5. Návod k obsluze
The PHILIPS Advance e-Vision IMH-100-D-BLS ballast is designed for automatic operation. Once properly installed and powered, it will ignite and operate the 100W Metal Halide lamp. The IntelliVolt® feature automatically adjusts to input voltagje mezi 120V a 277V.
- Lamp End-of-Life (EOL) Detection: The ballast is equipped with EOL detection to safely shut down the lamp when it reaches the end of its operational life, preventing potential hazards.
- Minimum Starting Temperature: The ballast is designed to start lamps reliably down to -30°C (-20°F).
6. Údržba
Minimal maintenance is required for the ballast itself. Regular inspection of the lighting system is recommended.
- Čištění: Keep the ballast and surrounding area free from dust and debris to ensure proper heat dissipation.
- Lamp Nahrazení: Při výměně alamp, always disconnect power first. After installing a new lamp, power must be reset to restore output.
- Tepelná ochrana: The ballast is thermally protected. If it shuts down due to overheating, allow it to cool down and ensure proper ventilation before resetting power.
7. Řešení problémů
Pokud lamp fails to operate, consider the following:
- Žádné světlo:
- Zkontrolujte, zda je připojeno a aktivní napájení.
- Zkontrolujte, zda jsou všechna zapojení bezpečná a správná dle schémat.
- Zkontrolujte lamp for damage or if it has reached its end-of-life. Replace if necessary and reset power.
- Ujistěte se, že lampholder is rated for 4.0kV pulse.
- Přerušovaný provoz:
- Zkontrolujte uvolněné spoje.
- Ensure the ballast is not overheating due to insufficient ventilation or high ambient temperatures.
- Lamp Cyklistika: This may indicate a lamp nearing its end-of-life or an issue with the ballast's EOL detection. Replace the lamp first. If the issue persists, consult technical support.
8. Specifikace
Elektrické údaje
| Parametr | Vstup 120V | Vstup 277V |
|---|---|---|
| Vstupní objemtage | 120V | 277V |
| Vstupní watty | 110W | 109W |
| Max. Vstupní proud | 0.92A | 0.40A |
| Open Circuit Voltage | 250 Vrms (Peak Voltage 4KV) | |
Obecné specifikace
- Číslo modelu: IMH-100-D-BLS
- Lamp Typ: (1) 100W Metal Halide (ANSI M90 or M140)
- Vstupní objemtage: IntelliVolt® 120V to 277V, 50/60Hz
- Účiník: High Power Factor (90% minimum)
- Minimum Starting Temperature: -30 °C (-20 °F)
- Hodnocení zvuku: A
- Maximum Case Temperature: 85 °C (185 °F)
- Ochrana: Thermally Protected, Lamp End-of-life (EOL) Detection
- Osvědčení: UL Listed Ballast, NRTL/C, CSA
- Shromáždění: Sestaveno v Mexiku
- Materiál: Kov
- Hmotnost položky: Approximately 0.01 ounces (Note: This weight seems unusually low and may be a data entry error. Refer to product packaging for accurate weight.)
9. Informace o záruce
For warranty details regarding your PHILIPS Advance e-Vision IMH-100-D-BLS ballast, please refer to the documentation included with your purchase or visit the official PHILIPS webZáruční podmínky se obvykle vztahují na vady materiálu a zpracování při běžném používání a servisu.
10. Podpora
If you require technical assistance or have questions not covered in this manual, please contact PHILIPS Advance technical support:
- Technical Information Line: 1-800-372-3331
- Umístění: Rosemont, IL
Please have your model number (IMH-100-D-BLS) available when contacting support.