APC AP7922

APC AP7922 32A 230V Switched Rack PDU User Manual

Model: AP7922 | Brand: APC by Schneider Electric

Zavedení

This manual provides essential instructions for the safe installation, operation, and maintenance of your APC AP7922 32A 230V Switched Rack PDU. The AP7922 is a rack-mountable power distribution unit designed to provide advanced power control and monitoring capabilities for IT equipment in data centers and server rooms. It features AC 230V input, Ethernet 10/100 connectivity, and 16 output connectors, all within a 2U, 19-inch form factor.

Důležité bezpečnostní informace

Please read and understand all safety instructions before installing or operating this equipment. Failure to follow these instructions could result in electric shock, fire, or serious injury.

  • Toto zařízení je určeno pouze pro vnitřní použití.
  • Connect the PDU to a properly grounded power source.
  • Do not attempt to open or service the PDU. Refer all servicing to qualified personnel.
  • Ensure the total current draw of connected equipment does not exceed the PDU's maximum current rating (32 Amps).
  • Před prováděním jakékoli údržby nebo instalace odpojte napájení.

Obsah balení

Při vybalení ověřte, zda jsou všechny položky přítomny:

  • APC AP7922 Switched Rack PDU
  • Průvodce instalací
  • Držáky pro montáž do racku
  • Serial configuration cable
  • CD s dokumentací

Vlastnosti produktu

The APC AP7922 Switched Rack PDU offers the following key features:

  • Spínané zásuvky: Remotely control power to individual outlets for power cycling, delayed sequencing, and load shedding.
  • Správa sítě: Full-featured network management interface via Ethernet 10/100 for remote monitoring and control.
  • Aktuální sledování: Monitor the aggregate current draw per PDU to prevent circuit overloads.
  • Konstrukce pro montáž do racku: Occupies 2U of rack space, compatible with standard 19-inch racks.
  • Výstupní konektory: Equipped with 16 C13 output connectors.
  • Vstupní objemtage: Supports AC 230V input.
APC AP7922 Switched Rack PDU front view with outlets and network port

Obrázek: Přední strana view of the APC AP7922 Switched Rack PDU, showing the 16 C13 outlets and network interface.

Pokyny pro nastavení

1. Montáž do racku

  1. Identify two available 2U spaces in your standard 19-inch equipment rack.
  2. Attach the provided rack-mounting brackets to the PDU using the screws supplied.
  3. Secure the PDU into the rack using appropriate rack screws. Ensure it is firmly seated and level.

2. Připojení napájení

  1. Connect the PDU's input power cord to a dedicated 230V, 32A power source. Ensure the power source is properly grounded.
  2. Do not overload the circuit. Verify that the total load of connected devices will not exceed 32 Amps.

3. Síťové připojení

  1. Connect a standard Ethernet cable from the PDU's network port to your network switch or router.
  2. The PDU will obtain an IP address via DHCP by default. Refer to the full user manual for static IP configuration.

Návod k obsluze

Powering On/Off Connected Devices

Once the PDU is powered and connected to the network, you can manage its outlets remotely.

  1. Access the PDU's web rozhraní zadáním jeho IP adresy do a web prohlížeč.
  2. Log in using the default credentials (refer to the full manual for details).
  3. Navigate to the outlet control section. From here, you can individually switch on, switch off, or cycle power to each of the 16 C13 outlets.

Monitoring Current Draw

The web interface also provides real-time monitoring of the aggregate current draw. This allows you to ensure that the PDU and its connected circuit are not overloaded.

Údržba

  • Čištění: Periodically clean the exterior of the PDU with a soft, dry cloth. Do not use liquid cleaners or solvents.
  • Aktualizace firmwaru: Zkontrolujte APC website for available firmware updates to ensure optimal performance and security. Follow the instructions provided with the firmware package for safe updating.
  • Správa kabelů: Ensure all power and network cables are neatly routed and secured to prevent accidental disconnections or damage.

Odstraňování problémů

ProblémMožná příčinaŘešení
PDU does not power on.Žádné vstupní napájení; vypnutý jistič.Verify the power cord is securely connected. Check the building's circuit breaker for the PDU's power source.
Nelze získat přístup web rozhraní.Incorrect IP address; network connectivity issue; PDU not powered.Ensure the PDU is powered on. Verify network cable connection. Confirm the correct IP address. Check network settings.
Outlets do not switch.Software issue; PDU fault.Try restarting the PDU. If the issue persists, contact technical support.
Alarm přetížení.Total current draw exceeds PDU rating.Disconnect non-essential equipment to reduce the load. Redistribute equipment across multiple PDUs if necessary.

Technické specifikace

FunkceDetail
Číslo modeluAP7922
ZnačkaSpolečnost APC by Schneider Electric
Form Factor2U Rack-mountable, 19-inch
Vstupní objemtage230 voltů AC
Vstupní proud32 Amps
Výstupní objemtage230 voltů AC
Výstupní proud32 Amps (Max)
Počet vývodů16
Typ konektoruC13
Síťové rozhraníEthernet 10/100
Wattage7360 wattů
Rozměry (V x Š x H)4.49 x 17.52 x 3.5 palce
Hmotnost0.7 kg
MateriálKov
BarvaČerný

Záruka a podpora

Informace o záruce

Produkty APC se obvykle dodávají se standardní zárukou výrobce. Prostudujte si prosím záruční list dodaný s produktem nebo navštivte oficiální webové stránky APC. website for detailed warranty terms and conditions specific to the AP7922 model.

Technická podpora

For technical assistance, troubleshooting, or to report issues, please contact APC customer support. You can find contact information and additional resources on the official Schneider Electric webmísto:

Oficiální informace o APC od společnosti Schneider Electric Webmísto

© 2023 APC by Schneider Electric. All rights reserved. Information in this document is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.