COOPER Lighting Solutions SLES 2 Socket Fit Light Engine Striplight
Product Usage Instructions
- Ensure power is switched off before installation.
- Mount the Socket-Fit Light Engine Striplight securely on the ceiling using the appropriate hardware.
- Connect the power supply following the provided wiring diagram.
- If emergency or fuse options are included, follow the additional instructions provided.
- Switch off the power and allow the lamp to cool if it has been in use.
- Remove the lamp cover by following the manufacturer’s instructions.
- Replace the lamp with the specified TLED T8 lamp option according to the lamp ordering logic.
- Reassemble the lamp cover securely before switching the power back on.
FAQ
- Q: Can I install the Socket-Fit Light Engine Striplight myself?
- A: While installation can be done by individuals with experience in electrical work, it is recommended to consult a professional electrician for safety and proper installation.
- Q: How do I know which lamp option to choose for replacement?
- A: Refer to the lamp ordering logic provided in the user manual to select the appropriate lamp based on length, series, and wattage requirements.
- Q: What should I do in case of a power outage with the emergency options?
- A: Follow the instructions provided for emergency and fuse options to ensure proper operation during power outages. Contact a qualified technician for assistance if needed.
SLES
- Socket-Fit Light Engine Striplight
Typical Applications
- Retail
- Office
- Education
- Warehouse
Interactive Menu
- Order Information page 2
- Energy and Performance Data
- Product Warranty
Product Certification
Product Features
Top Product Features
- Flip-up sockets, snap-on aligner, and tool-less cover reduce fixture installation time
- Replaceable TLED lamps lower maintenance costs without removing the fixture
- DLC-compliant lamps maximize energy savings and rebates
- TLEDs are 4ft long and come in 3500, 4000 or 5000K CCT
- Fixtures come in 4ft or 8ft lengths; T8 TLED lamps included (lamps shipped separately)
Dimensional Details
Order Information
Fixture and Lamp Ordering Logic
- SAMPLE ORDER NUMBER: 4SLES-2-T8-2G-B835-U
Length | Series | Lamp Rows | Emergency and Fuse Options | Wattage, Material, CCT/CRI (5), (6) | Options | Packaging | |
4=4 ft. Length 8T=8 ft. long Tandem | SLES=Socket-fit Light Engine Striplight | 1=1 Lamp/4 ft. 2=2 Lamps/4 ft. | [Blank]=None GL=Single Element Fuse GM=Double Element Fuse EL12=12.5W Inverter (1), (2) GTR=Bodine Transfer Relay (3), (4) | Type B Glass TLED T8-1G-B=9.9 watts T8-2G-B=12 watts T8-3G-B=14.5 watts | CRI / CCT 835=80CRI, 3500K 840=80CRI, 4000K 850=80CRI, 5000K | PAF=Paint after fabrication 6-3/18 SJT-C&P-515P=Cord & Plug (120V) (15 AMP) (7) 6-3/18 SJT-C&P-L715P=Cord & Plug (277V) (15 AMP) (7) PI/CPI=Plug-In Option (7), (8) | U=Unit Pack |
Notes (1) Factory installed with integral test switch/indicator/laser test. For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency inverter (152 lm/W x 10 = 1520 lumens). (2) 12.5W inverter works for TLEDs up to 15W. (3) Used to bypass local control during outage. Must be used in conjunction with UL 1008 device (provided by others). (4) Must specify voltage as 120V or 277V when ordering these devices. | Notes (5) TLEDs are shipped separately from luminaire. (6) TLED Philips lamps are standard. | Notes (7) Socket brackets left uninstalled. (8) Refer to Strip Accessories Guide for the PI/CPI ordering guide. |
Accessories
Accessories (order separately) |
A-1-B/SPACER-B=Spacer 1-1/2″ to 2-1/2″ from ceiling (Use 2 Per Fixture) GRP-SSF-U=Gripper Hanger (Use 2 Per Fixture) AYC-CHAIN/SET-U=36″ Chain Hanger (Use 1 Set Per Fixture) SCF=Fixed Stem Set (Specify Length) SCS=Swivel Stem Set (Specify Length) SCA=Adjustable 48″ Stem Set CCA-xx-NPF/PFS/PFC=Adjustable cable set – 48″ or 120″ (9) CLC-SSF-B=Long Channel Connector SSF SSF-ASY-4-B=Asymmetric Reflector (4′ long) SSF-SYM12-4-B =12″ Symmetric Reflector WG/SSF-4FT-B=4′ Wire Guard TOGGLE-10=Single Toggle No. 2 10FT long Y-TOGGLE- -2PK=(2) Y-Toggle Cable Kits (Specify 10 or 30 for length in feet) |
Notes (9) Specify Length, call out non-power feed (NPF), straight (PFS), or curly power feed (PFC) |
Lamp Specification / Performance Table (Glass)
Lamp | Philips LED T8 lamp description | Watts | CRI | CCT (K) | Type | Lumens | Lens Material | Efficacy (lm/W) | Philips 12NC | DLC ID |
MainsFit Glass TLED – 4FT | ||||||||||
T8-1G-B835 | 9.9T8/COR/48-835/MF15/G 10/1 | 9.9 | 80 | 3500 | B | 1600 | Glass | 162 | 929002483704 | PJWBAG7L |
T8-1G-B840 | 9.9T8/COR/48-840/MF16/G 10/1 | 9.9 | 80 | 4000 | B | 1650 | Glass | 167 | 929002483804 | P4GNLB60 |
T8-1G-B850 | 9.9T8/COR/48-850/MF16/G 10/1 | 9.9 | 80 | 5000 | B | 1650 | Glass | 167 | 929002483904 | PNRHRC3T |
T8-2G-B835 | 12T8/COR/48-835/MF17/G 10/1 | 12 | 80 | 3500 | B | 1700 | Glass | 136 | 929002484104 | P81MG6WR |
T8-2G-B840 | 12T8/COR/48-840/MF18/G 10/1 | 12 | 80 | 4000 | B | 1800 | Glass | 144 | 929002484204 | PXKUDN50 |
T8-2G-B850 | 12T8/COR/48-850/MF18/G 10/1 | 12 | 80 | 5000 | B | 1800 | Glass | 144 | 929002484304 | PVDPRFDJ |
T8-3G-B835 | 14.5T8/COR/48-835/MF20/G 10/1 | 14.5 | 80 | 3500 | B | 2000 | Glass | 133 | 929002484504 | PWIUOJVW |
T8-3G-B840 | 14.5T8/COR/48-840/MF21/G 10/1 | 14.5 | 80 | 4000 | B | 2100 | Glass | 140 | 929002484604 | P7YG7OL7 |
T8-3G-B850 | 14.5T8/COR/48-850/MF21/G 10/1 | 14.5 | 80 | 5000 | B | 2100 | Glass | 140 | 929002484704 | PDR4QOQZ |
Fixture Performance Data
Ordering Information/Performance
Lumen Output, 83 CRI | Efficacy | Wattage | ||||||
Catalog | Product Description | 3500K | 4000K | 5000K | 3500K | 4000K | 5000K | 120-277V |
4SLES-1-T8-1G-B8XX-U | 4ft 1-lamp T8 SLES strip, 120-277V, 9.9W CorePro Type B TLED included, Glass TLED | 1706 | 1760 | 1760 | 172 | 178 | 178 | 9.9 |
4SLES-2-T8-1G-B8XX-U | 4ft 2-lamp T8 SLES strip, 120-277V, 9.9W CorePro Type B TLED included, Glass TLED | 3323 | 3427 | 3427 | 168 | 173 | 173 | 19.8 |
4SLES-1-T8-2G-B8XX-U | 4ft 1-lamp T8 SLES strip, 120-277V, 12W CorePro Type B TLED included, Glass TLED | 1813 | 1920 | 1920 | 151 | 160 | 160 | 12 |
4SLES-2-T8-2G-B8XX-U | 4ft 2-lamp T8 SLES strip, 120-277V, 12W CorePro Type B TLED included, Glass TLED | 3531 | 3739 | 3739 | 147 | 156 | 156 | 24 |
4SLES-1-T8-3G-B8XX-U | 4ft 1-lamp T8 SLES strip, 120-277V, 14.5W CorePro Type B TLED included, Glass TLED | 2133 | 2240 | 2240 | 147 | 154 | 154 | 14.5 |
4SLES-2-T8-3G-B8XX-U | 4ft 2-lamp T8 SLES strip, 120-277V, 14.5W CorePro Type B TLED included, Glass TLED | 4154 | 4362 | 4362 | 143 | 150 | 150 | 29 |
8TSLES-1-T8-1G-B8XX-U | 8ft Tandem 1-lamp T8 SLES strip, 120-277V, (2) 9.9W CorePro Type B TLED included, Glass TLED | 3413 | 3519 | 3519 | 172 | 178 | 178 | 19.8 |
8TSLES-2-T8-1G-B8XX-U | 8ft Tandem 2-lamp T8 SLES strip, 120-277V, (4) 9.9W CorePro Type B TLED included, Glass TLED | 6647 | 6855 | 6855 | 168 | 173 | 173 | 39.6 |
8TSLES-1-T8-2G-B8XX-U | 8ft Tandem 1-lamp T8 SLES strip, 120-277V, (2) 12W CorePro Type B TLED included, Glass TLED | 3626 | 3839 | 3839 | 151 | 160 | 160 | 24 |
8TSLES-2-T8-2G-B8XX-U | 8ft Tandem 2-lamp T8 SLES strip, 120-277V, (4) 12W CorePro Type B TLED included, Glass TLED | 7062 | 7478 | 7478 | 147 | 156 | 156 | 48 |
8TSLES-1-T8-3G-B8XX-U | 8ft Tandem 1-lamp T8 SLES strip, 120-277V, (2) 14.5W CorePro Type B TLED included, Glass TLED | 4266 | 4479 | 4479 | 147 | 154 | 154 | 29 |
8TSLES-2-T8-3G-B8XX-U | 8ft Tandem 2-lamp T8 SLES strip, 120-277V, (4) 14.5W CorePro Type B TLED included, Glass TLED | 8309 | 8724 | 8724 | 143 | 150 | 150 | 58 |
Note: Lamps shipped separately from the fixture.
Load Data
4′ | 8′ | |
PF | > .9 | |
THD% | < 20% | |
Low Temp Start | -20º C | |
Max Ambient Temp | 45º C | |
Weight lbs. | 4.4 | 9.8 |
Shipping Data (SLES fixture only)
Catalog No. | Length | Wt. | Pallet Qty. | Pallet Weight |
4SLES | 4 ft. | 5.1 lbs. | 90 | 570 lbs. |
8TSLES | 8 ft. | 10.2 lbs. | 72 | 784 lbs. |
Product Specifications
Construction
- Die-formed white steel housing channel
- Multiple channel KOs fit standard trade size conduits
- Available in 4ft and 8ft lengths
- The lamp holder bracket (flip-up socket) rotates and locks in place
- Steel channel/wireway cover secured using 1/4-turn fasteners
- The end plate converts to a snap-on channel aligner for continuous row mounting
Electrical
- Fully tested electrical systems comply with UL TLED requirements
- TLED lamp sources are Type B:
- Energized using direct wire to each TLED socket
- Universal voltage (120-277V)
- Dual-ended lamps prevent damage if the wrong type of lamp is installed.
Performance
- TLEDs provide easy maintenance and replacement similar to traditional fluorescent lamps
- Specialized sockets and electrical protection circuits ensure safety, durability, and electrical code compliance
- Refer to the lamp table for TLED lamp type, lens material,l and lumen data
- The performance will vary by lamp selection and type
- TLED lamps are rated to L70/50K life hours
- TLED lamp included with the order. Shipped separately from fixture
Warranty
- Fixture = 5 years
- Glass lamp = 5 years
Finish
- Pre-treated with multi-stage iron phosphate
- Standard baked white enamel finish
- PAF option available
Compliance
- cULus listed for damp locations
- Rated for -20C to 45C ambient operation
- IESNA LM-79 and LM-80 compliant TLED lamps
- Meets FCC, part 15 Class A requirements
- DesignLights Consortium (R) qualified and classified under DLC Standard
- Suitable for use in closet storage spaces when installed by NFPA-70 and NEC 410.16 spacing requirements
Emergency Options
- Integrated factory installed EL12 inverter option for TLED fixture emergency backup use
- Only ONE lamp will be powered by an EL inverter emergency backup
Mounting
- SLES can be installed using various mounting methods. Numerous options and accessories are available.
- SLES should not be vertically mounted on the wall
CONTACT
Cooper Lighting Solutions
- 1121 Highway 74 South
- Peachtree City, GA 30269
- P: 770-486-4800
- www.cooperlighting.com
© 2022 Cooper Lighting Solutions All Rights Reserved.
Specifications and dimensions are subject to change without notice.