COMMAND ACCESS MLRK1 Motorized Latch Retraction Kit
INSERT INSTRUCTIONS
The Command Access MLRK1 is a field installable motorized latch-retraction kit for:
- MLRK1-TEL – Tell 9500 series devices
- MLRK1-TTN – Phoenix Titan 66 series devices
- MLRK1-PHI – Philadelphia Hardware 9000 series devices
KIT INCLUDES
A 1 – 60281 – MLRK1
B 2 – 40786 – M4 screws
C 2 – 40351 – Lock Washers
D 1 – 40014 – Phillips Screw with Lock washer
E 1 – 50944 – Molex Pigtail
TOOLS REQUIRED
Cordless Drill or Phillips Screwdriver
SPECIFICATIONS
- Input Voltage: 24VDC +/- 10%
Standard torque AVERAGE LATCH RETRACTION CURRENT: 900 mA - High torque AVERAGE LATCH RETRACTION CURRENT: 2A
- Average holding current: 215 ma
- Wire gauge: Minimum 18 gauge
- Direct wire run – no relays or access control units in-between power supply & module
Recommended Power Supplies: Use a power limited class 2 power supply
All Command Access exit devices & field installable kits have been thoroughly cycle tested with Command Access power supplies at our factory. If you plan on using a non-Command power supply it must be a filtered & regulated linear power supply.
Optional built-in rex
- SPDT – Rated .5a @24V
- green= Common (C)
- Blue = normally open (NO)
- grey = normally closed (NC)
Technical Information
Setting PUSH TO SET (PTS)
**Important Info**
Make sure to set PTS before finishing installation
- Step 1 – Select your preferred torque mode (ships in standard torque). Press the device push pad to the desired setting. (We recommend to fully depress and release 5%, giving the device room for changing door conditions.)
- Step 2 – While depressing the push pad, apply power. (i.e. presenting the credential to the reader).
- Step 3 – Continue to keep the pad depressed, the device will beep 6 times. After the beeps have stopped, release the pad and the adjustment is now complete. If not to your liking repeat the 3 steps.
- Step 4 – Once you have found the correct location. Change Dip Switch 2 to PTS Programming OFF.
Troubleshooting & Diagnostics
Beeps | Explanation | Solution |
2 Beeps | Over Voltage | > 30V unit will shut down. Check voltage & adjust to 24 V. |
3 Beeps | Under Voltage | < 20V unit will shut down. Check voltage & adjust to 24 V. |
4 Beeps | Failed Sensor | Verify all 3 sensor wires are installed correctly. Replace sensor if problem persists by contacting office. |
5 Beeps | Retraction or dogging failure | After 1st fail: 5 beeps then immediately attempts to retract again. After 2nd fail: 5 beeps with pause in-between for 30 seconds then device attempts to retract again. After 3rd fail: 5 beeps every 7 minutes, device will not attempt to retract. To Reset: Depress bar for 5 seconds at any time. |
6 Beeps | PUSH TO SET | Device is recording it’s new position and power mode after the 6th beep. |
INSTALLATION INSTRUCTIONS
- SLIDE HOUSING OFF TO REVEAL BASERAIL. YOU MAY HAVE TO REMOVE TWO SCREWS FROM UNDERSIDE OF HOUSING BEFORE SLIDING OFF.
- IF YOUR DEVICE HAS DOGGING, YOU NEED TO REMOVE DOG-GING ASSEMBLY.
- IF YOUR DEVICE HAS DOGGING, YOU NEED TO REMOVE TAIL PIECE BOTH SCREWS FROM CONNECTING ROD.
- INSTALL KIT ON TOP OF BASERAIL & ATTACHING BRACKET, SLIDING UNDERNEATH THE CONNECTING ROD.
- INSTALL (40064) SCREW TO SECURE ATTACHING BRACKET TO CONNECTING ROD
- INSTALL BOTH (40786) SCREWS & (40351) LOCK WASH-ERS PARTIALLY, SO THE BASERAIL CAN STILL SLIDE BACK INTO THE HOUSING.
- SLIDE BASERAIL WITH MOTOR KIT BACK INTO HOUSING. MAKE SURE IT’S IN THE MIDDLE CHANNEL.
- ONCE HOUSING IS ALL THE WAY ON, GO BACK TO MOTOR MOUNT SCREWS & TIGHTEN ALL THE WAY TO KEEP HOUSING IN PLACE.
- NEXT, HOOK UP TO POWER AND SET THE PUSH-TO-SET ADJUSTMENT. FOLLOW STEPS BELOW TO SET, REMEMBERING TO TURN THE PROGRAMMING SWITCH TO THE OFF POSITION WHEN COMPLETED.
Setting PTS
**Important Info**
Make sure to set PTS before finishing installation
- Step 1 – Select your preferred torque mode (ships in standard torque). Press the device push pad to the desired setting. (We recommend to fully depress and release 5%, giving the device room for changing door conditions.)
- Step 2 – While depressing the push pad, apply power. (i.e. presenting the credential to the reader).
- Step 3 – Continue to keep the pad depressed, the device will beep 6 times. After the beeps have stopped, release the pad and the adjustment is now complete. If not to your liking repeat the 3 steps.
- Step 4 – Once you have found the correct location. Change Dip Switch 2 to PTS Programming OFF.
Documents / Resources