User Guide for felicitysolar models including: 358-010371-02, FLA48500 LiFePO4 Battery System for Households, FLA48500, LiFePO4 Battery System for Households, Battery System for Households, System for Households, Battery System, System
LiFePO4 battery storage 25 kWh Felicity Solar
Special Attention: Due to the built-in protection board of the lithium battery pack is with over-discharge protection function, it is strongly recommended to stop using the load when the battery pack is over-discharged. The battery pack cannot be repeatedly activated for discharge. Or the battery may be failed to be activated by the AC or PV activation cable ( It requires a special charging ...
File Info : application/pdf, 9 Pages, 3.73MB
DocumentDocumentLiFePO4 Battery System for Households Make life full of hope USER GUIDE LiFePO4 Battery System for Households 358-010371-02 Contents 1 ABOUT THIS MANUAL ..................................................................................... 1 1.1 Purpose ................................................................................................. 1 1.2 Scope .................................................................................................... 1 1.3 Safety Instructions .................................................................................. 1 2 INTRODUCTION .............................................................................................. 2 2.1 Features................................................................................................. 2 2.2 Product Overview ................................................................................... 2 2.3 Specifications ........................................................................................ 4 2.4 Recommended Settings .......................................................................... 4 3. INSTALLATION ............................................................................................... 5 3.1 Unpacking and Inspection ...................................................................... 5 3.2 Mounting the Unit .................................................................................. 5 3.3 Connection for Parallel Mode .................................................................. 5 4. OPERATION ................................................................................................... 7 4.1 Switch On/Off.......................................................................................... 7 4.2 LCD Display icons .................................................................................. 7 4.3 BMS information Page ............................................................................. 8 4.4 Fault Code Table .................................................................................... 9 4.5 DIP switch SW1-SW4 Description ........................................................... 10 5. EMERGENCY SITUATIONS ............................................................................. 11 5.1 Fire .......................................................................................... . . .......... 11 5.2 Leaking Batteries .................................................................... ...... . ....... 11 5.3 Wet Batteries ........................................................................................ 11 5.4 Damaged Batteries ................................................................................. 11 5.5 Warranty ............................................................................ . . . . .............. 11 LiFePO4 Battery System for Households 1 ABOUT THIS MANUAL 1.1 Purpose This manual describes the introduction, installation, operation and emergency situations of the battery bank. Please read this manual carefully before installations and operations. Keep this manual for future reference. 1.2 Scope This manual provides safety and installation guidelines as well as information on tools and wiring. 1.3 Safety Instructions WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference. 1.Before using the unit, read all instructions and cautionary markings on the unit, the batteries and all appropriate sections of this manual. 2. CAUTION -- To reduce risk of injury,damage,even burst. please use it following using manual. In case of causing personal 3. Do not disassemble the battery. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of fire. 4. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk. 5. CAUTION Only qualified personnel can install this device with inverter. 6. For optimum operation of this battery, please follow required spec to select appropriate cable size. 7. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion or fire. 8. Please strictly follow installation procedure. 9. To support full output load, at least 2 sets for inverter larger than 6KVA in parallel connection. 10. GROUNDING INSTRUCTIONS - This System should be connected to a permanent grounded wiring system. Be sure to comply with local requirements. 11. NEVER cause AC output and DC input short circuited. Do not connect to the mains when DC input short circuits. 12. Warning!! Only qualified service persons are able to service this device. 13. Battery should be installed indoor and kept away from water, high temperature mechanical force and flames. 14. Do not install the battery in any environment of temperature below 0°C or over 55°C,and humidity over 80%. 15. Do not put any heavy objects on the battery. 1.4 Can be connected in parallel 1. The batteries can be connected in parallel. Series connection is not allowed. Use in upright position only. 2. The batteries are not allowed to connected with PWM controller for charging. 3. The batteries are allowed to connected with MPPT controller for charging, but the maximum PV voltage in the system must be less than 100Vdc. Special Attention: Due to the built-in protection board of the lithium battery pack is with over-discharge protection function, it is strongly recommended to stop using the load when the battery pack is over-discharged. The battery pack cannot be repeatedly activated for discharge. Or the battery may be failed to be activated by the AC or PV activation cable ( It requires a special charging activation method), so cannot be charged. Therefore, when the battery pack is low power, please charge the battery as soon as possible when main power or solar energy is available. 01 LiFePO4 Battery System for Households 2. INTRODUCTION The battery system main using solar power system for family house. It also have a with to controller the battery easily and protect our Household application timely. 2.1 Features · LiFePO: Higher safe performance and longer cycle life. · Multiple Protection: Built-in smart BMS, Breaker and Fuse. · Flexible Installation: Movalbe type Floor-Mounted. · Wide Compatibility: Compatible with leading inverter brands. · High Scalability: Capacity up to 375kWh. · Long Warranty: 7 Years. 2.2 Product OverView A 02 LiFePO4 Battery System for Households 1 A 2 56 3 4 7 8 1. LCD display 4. Battery Positive + 7.Earth wire 2. Power On/Charging indicator 5. Switch 8. Breaker 3.Battery Negative 6. Communication port 03 LiFePO4 Battery System for Households 2.3 Specifications Model FLA48500 Capacity 25kWh Battery Type LiFePO4 Nominal Voltage 51.2V Operating Voltage 44.8-57.6V Recommend Charge/Discharge Current[1] 200A Recommend Charge/Discharge Power[1] 10,000W Maximum Charge/Discharge Current(15s) 300A Maximum Charge/Discharge Power(15s) 15,000W Depth of Discharge(DOD) 95% Scalability Up to 15 units in parallel(375kWh) Communication RS485 / CAN Protection Level IP21 Cycle Life[2] 6000 Cycles Charging Temperature Range 0-55 °C Discharging Temperature Range -20-55°C Display LCD+LED Installation Floor-Mounted Protection Built-in smart BMS, Breaker, Fuse Warranty 7 Years Net Weight 218kg Gross Weight 248kg Product Dimension 718x380x990mm Package Dimension 825x498x1162mm [1] Recommend charge/discharge current/power is affected by temperature and SOC. [2] Test conditions: 0.2C Charging/Discharging @25°C , 80% DOD. 2.4 Recommended Settings Lithium battery pack is not same as lead-acid battery, so for the devices which you connect with the battery pack for charging or discharging, such as inverters, MPPT charger controllers or UPS, please implement pre-settings as recommended settings as below before you launched them. Setting FLA48500 Max. Charging Voltage 57.6V Floating charging Voltage 57.6V Max. Charging Current 200A*N Cut-off voltage 48V Notes: "N" means the number of battery packs connected in parallel. 04 LiFePO4 Battery System for Households 3. Installation Procedure 3.1 Setup Script Step 1: Remove the wooden board from the outer box, leaving only the bottom pallet and product A LiFePO4 Battery System for Households Step 3: Take out the fixed parts of the pallet, align them with the U-shaped holes at both ends of the pallet, and clamp them onto the pallet to form unloading steps.Finally, use the M6X12 screw to lock the fixed parts to the baseplate. A A Step 2: Remove the fastening screws on the pallet fixture A Step 4: Push the product down the pallet along the steps and move it to the installation position A 05 06 LiFePO4 Battery System for Households 3. INSTALLATION 3.1 Unpacking and Inspection Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items inside of package. NO NAME SPECIFICATION PICTURE 1 RS485 cable Battery terminal5B6A PCS terminal5B6A 1 2 2 Communication line Used for Communication among batteries 3 Cables Used for battery parallel connection Wire AWG#2 3 4 User manual User manual 4 5 Guarantee card Guarantee card 5 6 CAN/485 com line 7 90 degree wiring terminals Spare for wiring at the output 8 2 M6X12 combination screws Fixed slide rail 9 Ethernet connector Ethernet connector 6 8 7 9 3.2 Mounting the Unit Consider the following points before selecting where to install: · Do not mount the battery on flammable construction materials. · The ambient temperature should be between 0°C and 45°C to ensure optimal operation. · The recommended installation position is to be adhered to the wall vertically. · Be sure to keep other objects and surfaces as shown in the right diagram to guarantee sufficient heat dissipation and to have enough space for removing wires. Please follow below steps to implement battery connection: 1.Assemble battery ring terminal based on recommended battery cable and terminal size. 2.Connect all battery packs as units requires. It's suggested to connect at least 2 sets for inverter larger than 10KVA in parallel connection. Note: If you need the battery wake-up when the grid back, connect the battery with grid use power adapter and communication line 1 shown in the package list. LiFePO4 Battery System for Households 3.3 Connection for Parallel Mode The LPBF series battery support to be connected in parallel for expansion. If you need one more battery bank work in parallel mode, connect the battery as shown in PIC 1. Main Circuit BTCB0606/BTCB0303 Step 1: The schematic diagram of the parallel connection of three battery packs is shown in Figure 1. Note:After completing the above steps, arbitrarily select the positive and negative poles of one of the battery packs to output. After confirming the correct connection of the inverter, controller and battery, you can turn on any of the switches and use the battery group happily. For pure off grid system ,the PV awake wire need to be connected with MPPT charge controller if the battery pack is charged by solar panels only . The connection diagram as below : Make life full of hope 07 08 7 LiFePO4 Battery System for Households 4. OPERATION Once the batteries are connected well, close the breaker to the ON block, press On/Off button to enable the output of the battery pack. 4.1 Switch On / Off 1.Switch on: press On/Off button to switch on the battery, then the battery will do self-inspection before enable output. The LCD will show the SOC. 2.Switch off: press and hold On/Off button for 1to3 seconds, the battery will shut down directly. Description for Communication port Picture PIN Description 1 Trigger-GND 2 Trigger-VCC 3 CANL-PCS 4 CANH-PCS 5 RS485-B 6 RS485-A 7 CANL 8 CANH DIP SWITCH 1-4 Communication Address 5 Termination Resister 09 LiFePO4 Battery System for Households A current or watt Short press A the switch button to switch watt and current Indicates battery level by 0-20%,21-40%, 41-60%61-80%,81-100%.(When charging,this icon is displayed for horse running;When discharging,the icon displays constant). Eg:"515"is the software version ;"400"is the IAP version and temporary version;"02"is the countdown. 10 LiFePO4 Battery System for Households Eg: Rated voltage is "51.2V"; model is "25.0KWH", "01"is the countdown. Eg: "52.0V" / "3.90KW" / "70%" refers to battery voltage. power and SOC. LiFePO4 Battery System for Households Cell ovetemperature Cell undertemperature Eg: "52.0V" / "120A" / "70%" refers to battery voltage. current and SOC. Eg:"52.0V" / "C09" / "70%" are battery voltage, fault code and SOC respectively, and Fault icon constant. Cell overvoltage Cell undervoltage Charge overcurrent Discharge overcurrent MOS overtemperature MOS undertemperature 11 4.5 DIP switch SW1-SW4 Description DIP switch SW1-SW4 Description Sw1 SW2 SW3 SW4 Remarks DIP switch SW5 Description 0 0 0 0 means ID=0,communication address is0x00/0x10 SW5 Remarks 1 0 0 0 means ID=1,communication address is0x01 0 1 0 0 means ID=2,communication address is0x02 means connect 1 120 resistor 1 1 0 0 means ID=3,communication address is0x03 0 0 1 0 means ID=4,communication address is0x04 means disconnect 0 120 resistor 1 0 1 0 means ID=5,communication address is0x05 0 1 1 0 means ID=6,communication address is0x06 1 1 1 0 means ID=7,communication address is0x07 0 0 0 1 means ID=8,communication address is0x08 1 0 0 1 means ID=9,communication address is0x09 0 1 0 1 means ID=10,communication address is0x0A 1 1 0 1 means ID=11,communication address is0x0B 0 0 1 1 means ID=12,communication address is0x0C 1 0 1 1 means ID=13,communication address is0x0D 0 1 1 1 means ID=14,communication address is0x0E 1 1 1 1 means ID=15,communication address is0x0F Remark: 1 in SW1-SW5 indicates ON status, and 0 indicates OFF status. Remark: When multiple battery packs communicate, the last battery pack SW5 needs to be in the ON status, otherwise the communication may have interference. Remark: When the battery pack ID is set to 0, it means stand-alone operation, and it is not necessary to detect whether the parallel condition is satisfied Remark: When the battery pack ID is set to 1-15, it means that the parallel operation is required, and it is necessary to detect whether the parallel condition is satisfied Remark: The parallel condition is that the difference between the battery voltage of the local battery and all the battery pack voltages is <3V, otherwise wait until the condition is satisfied 12 LiFePO4 Battery System for Households 5. EMERGENCY SITUATIONS Felicity cannot guarantee battery absolute safety. 5.1 Fire In case of fires, make sure that the following equipment is available near the system. · SCBA (self-contained breathing apparatus) and protective gear in compliance with the Directive on Personal Protective Equipment 89/686/EEC. · NOVEC 1230, FM-200, or dioxide extinguisher Batteries may explode when heated above 150°C. KEEP FAR AWAY from the battery if it catches fire. 5.2 Leaking Batteries If the battery pack leaks electrolyte, avoid contact with the leaking liquid or gas. If one is exposed the leaked substance, immediately perform the cations described below. · Inhalation: Evacuate the contaminated area, and seek medical attention. · Contact with eyes: Rinse eyes with running water for 5 minutes, and seek medical attention. · Contact with skin: Wash the affected area thoroughly with soap and water, and seek medical attention. · Ingestion: Induce vomiting, and seek medical attention. 5.3 Wet Batteries If the battery pack is wet or submerged in water, do not let people access it, and contact your supplier for help. 5.4 Damaged Batteries Damaged batteries are not fit for use and are dangerous and must be handled with the utmost care. It may leak electrolyte or produce flammable gas. If the battery pack seems to be damaged, pack it in its original container, and then return it to your supplier. 5.5 Warranty Products that are operated strictly in accordance with the user manual are covered by the warranty. Any violation of this manual may void the warranty. Limitation of Liability Any product damage or property loss caused by the following conditions, Felicity does not assume any direct or indirect liability. · Product modified, design changed or parts replaced. · Changed, or attempted repairs and erasing of series number or seals; · System design and installation are not in compliance with standards and regulations; · The product has been improperly stored in end user's premises; · Transport damage (including painting scratch caused by movement inside packaging during shipping). A claim should be made directly to shipping or insurance company. 13 LiFePO4 Battery System for HouseholdsGPL Ghostscript 9.52