D140 4 Way Cassette
“
Specifications
- Product: Direct Expansion Indoor Unit for VRF
4-way Cassette - Model: Q4DN-3-XY D28 – D140
- Refrigerant: R-410A
Product Usage Instructions
General Technical Data
The indoor unit is available in various models with different
cooling and heating capacities, power supplies, and technical
specifications. Below are the general technical data for each
model:
Model | Cooling Capacity (kW) | Heating Capacity (kW) | Power Supply | Fan Motor Type | Air Flow Rate (m3/h) | Sound Pressure Level (dB) |
---|---|---|---|---|---|---|
Q4DN-3-XY D28 | 2.8 | 3.2 | 1-phase, 220-240V, 50Hz | DC motor | 790 | 30 |
Installation Instructions
1. Ensure the power supply matches the unit requirements.
2. Connect the liquid and gas pipes according to the specified
sizes.
3. Install the drain pipe properly to avoid leakage.
Maintenance and Cleaning
1. Regularly clean the indoor coil and fan motor to maintain
optimal performance.
2. Check for any refrigerant leaks and consult a professional if
needed.
FAQ
Q: What should I do if the unit is not cooling/heating
properly?
A: Check if the filters are clean and ensure proper airflow. If
the issue persists, contact a certified technician for
inspection.
Q: Can I use a different refrigerant than R-410A?
A: It is recommended to use the specified refrigerant to
maintain product efficiency and performance.
“`
Direct expansion indoor unit for VRF
4-way cassette
Q4DN-3-XY D28 – D140
TBEOCLHLNEITCTIALNOBUTLELCENITTCION
EEV
R-410A
SIZE COOLING CAPACITY kW HEATING CAPACITY kW
D28 D36 D45 D56 D71 D80 D90 D100 D112 D140 D160 D180 2,8 3,6 4,5 5,6 7,1 8,0 9,0 10,0 11,2 14,0 16,0 18,0 3,2 4,0 5,0 6,3 8,0 9,0 10,0 11,2 12,5 16,0 18,0 20,0
General technical data
Model Power supply
Cooling1
Capacity Power input
Heating2 Fan motor type Indoor coil
Air flow rate3
Capacity
Power input
Number of rows Tube pitch × row pitch Fin spacing and type Tube OD and type Dimensions (L×H×W) Number of circuits
kW kBtu/h
W kW kBtu/h W
mm mm mm mm
m3/h
Sound pressure level4
dB(A)
Sound power level
dB(A)
Net dimensions6 (W×H×D)
mm
Main body
Packed dimensions (W×H×D) mm
Net/Gross weight
kg
Net dimensions (W×H×D)
mm
Panel
Packed dimensions (W×H×D) mm
Net/Gross weight
kg
Refrigerant type
Design pressure (H/L)
MPa
Liquid/Gas pipe
mm
Pipe connections
Drain pipe
mm
Q4DN-3-XY D28
Q4DN-3-XY D36
Q4DN-3-XY D45
Q4DN-3-XY D56
1-phase, 220-240V, 50Hz
2,8
3,6
4,5
5,6
9,6
12,3
15,4
19,1
17
17
23
23
3,2
4,0
5,0
6,3
10,9
13,7
17,1
21,5
17
17
23
23
DC motor
1
1
2
2
18×10,72
1,2 Hydrophilic aluminum
5 Inner-groove
2165×144×10,72
4
4
8
8
790/740/691/641/591/542/492
840/787/733/680/6 26/573/519
840/791/741/692/6 42/593/543
30/29/28/27,5/27/26/25 30/29/28/27,5/27/26/25 33/32/31/30/29/28/27
33/32/31/30/29/28/27
43/42/41/41/40/39/39
44/43/42/42/41/40/39
49/48/47/46/45/44/43
49/48/48/47/46/45/44
840×204×840
940×250×940
18/20,5
19,5/22
950×53×950
1020×90×1020
5,6/7,3
R410A/R32
4,4/2,6
6,35/12,7
OD 25
Notes: 1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. 2. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. 3. Air flow rate are from the highest speed to the lowest speed, total 7 rates for each model. 4. Sound pressure level is from highest level to lowest level, total 7 levels for each model. Sound pressure level is measured 1.5m below the unit in a semi-anechoic chamber. 5. The dimension is only the body size, excluding the size of the installation lug, connecting copper pipe, etc. For detailed dimensions, please refer to the installation manual. 6. Exposed height of the panel after being installed on the ceiling.
2
General technical data
Model Power supply
Cooling1
Capacity Power input
Heating2
Capacity
Power input
Fan motor type
Number of rows
Tube pitch × row pitch
Indoor coil
Fin spacing and type Tube OD and type
Dimensions (L×H×W)
Number of circuits
Air flow rate3
Sound pressure level4
Sound power level
Net dimensions6 (W×H×D)
Main body
Packed dimensions (W×H×D)
Net/Gross weight
Net dimensions (W×H×D)
Panel
Packed dimensions (W×H×D)
Net/Gross weight
Refrigerant type
Design pressure (H/L)
Liquid/Gas pipe Pipe connections
Drain pipe
kW kBtu/h
W kW kBtu/h W
mm mm mm mm
m3/h dB(A) dB(A) mm mm
kg mm mm kg
MPa mm mm
Q4DN-3-XY D71
7.1 24.2 31 8.0 27.3 31
2
11 1000/943/886/829/772/715/658
37/36/34/33/32/30/29 51/50/49/48/47/46/46
Q4DN-3-XY D80 1-phase, 220-240V, 50Hz
8.0 27.3 41 9.0 30.7 41 DC 2 18×10.72 1.2 Hydrophilic aluminum 5 Inner-groove 2165×198×21.44 11 1330/1239/1148/1057/965/874/783 38/37/35/34/32/31/29 53/52/51/50/49/48/47 840×246×840 940×295×940 22/24.5 950×53×950 1020×90×1020 5.6/7.3 R410A/R32 4.4/2.6 9.52/15.9 OD 25
Q4DN-3-XY D90
9.0 30.7 43 10.0 34.1 43
2
11 1330/1239/1148/1057/965/874/783
38/37/35/34/32/31/29 54/53/52/51/50/49/48
Notes: 1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. 2. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. 3. Air flow rate are from the highest speed to the lowest speed, total 7 rates for each model. 4. Sound pressure level is from highest level to lowest level, total 7 levels for each model. Sound pressure level is measured 1.5m below the unit in a semi-anechoic chamber. 5. The dimension is only the body size, excluding the size of the installation lug, connecting copper pipe, etc. For detailed dimensions, please refer to the installation manual. 6. Exposed height of the panel after being installed on the ceiling.
3
General technical data
Model Power supply
Cooling1
Capacity Power input
Heating2
Capacity
Power input
Fan motor type
Number of rows
Tube pitch × row pitch
Indoor coil
Fin spacing and type Tube OD and type
Dimensions (L×H×W)
Number of circuits
Air flow rate3
Sound pressure level4
Sound power level
Net dimensions6 (W×H×D)
Main body
Packed dimensions (W×H×D)
Net/Gross weight
Net dimensions (W×H×D)
Panel
Packed dimensions (W×H×D)
Net/Gross weight
Refrigerant type
Design pressure (H/L)
Liquid/Gas pipe Pipe connections
Drain pipe
kW kBtu/h
W kW kBtu/h W
mm mm mm mm
m3/h dB(A) dB(A) mm mm
kg mm mm kg
MPa mm mm
Q4DN-3-XY D100
Q4DN-3-XY D112
Q4DN-3-XY D140
1-phase, 220-240V, 50Hz
10,0
11,2
14,0
34,1
38,2
47,8
54
61
89
11,2
12,5
16,0
38,2
42,7
54,6
54
61
89
DC
2
2
3
18×10,72
1.2 Hydrophilic aluminum
5 Inner-groove
2165×252×21.44
2165×252×32.6
14
14
14
1445/1363/1282/1200/1118/1037/955 1600/1497/1393/1290/1186/1083/979 1730/1624/1518/1412/1306/1200/1094
39/38/37/36/35/34/33
41/40/38/37/36/34/33
43/42/40/39/37/36/34
54/53/52/51/50/50/49
57/56/55/54/53/52/51
58/57/56/55/54/53/52
840×288×840
940×335×940
24/26.5
26.5/29
950×53×950
1020×90×1020
5.6/7.3
R410A/R32
4.4/2.6
9.52/15.9
OD 25
Notes: 1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. 2. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. 3. Air flow rate are from the highest speed to the lowest speed, total 7 rates for each model. 4. Sound pressure level is from highest level to lowest level, total 7 levels for each model. Sound pressure level is measured 1.5m below the unit in a semi-anechoic chamber. 5. The dimension is only the body size, excluding the size of the installation lug, connecting copper pipe, etc. For detailed dimensions, please refer to the installation manual. 6. Exposed height of the panel after being installed on the ceiling.
4
General technical data
Model Power supply
Cooling1
Capacity Power input
Heating2
Capacity
Power input
Fan motor type
Number of rows
Tube pitch × row pitch
Indoor coil
Fin spacing and type Tube OD and type
Dimensions (L×H×W)
Number of circuits
Air flow rate3
Sound pressure level4
Sound power level
Net dimensions6 (W×H×D)
Main body
Packed dimensions (W×H×D)
Net/Gross weight
Net dimensions (W×H×D)
Panel
Packed dimensions (W×H×D)
Net/Gross weight
Refrigerant type
Design pressure (H/L)
Liquid/Gas pipe Pipe connections
Drain pipe
kW kBtu/h
W kW kBtu/h W
mm mm mm mm
m3/h dB(A) dB(A) mm mm
kg mm mm kg
MPa mm mm
Q4DN-3-XY D160
Q4DN-3-XY D180
1-phase, 220-240V, 50Hz
16,0
18,0
54.6
61.4
110.0
145.0
18.0
20.0
61.4
68.2
110.0
145.0
DC
3
3
18×10.72
1.2 Hydrophilic aluminum
5 Inner-groove
2165×144×10.72
2165×144×10.72
14
14
2100/1900/1760/1630/1500/1380/1270
2300/2140/1960/1770/1600/1430/1270
48/46/44/43/41/39/37
52/49/47/45/42/39/38
56/53/51/49/47/46/45
59/56/54/51/49/46/45
950×300×950
950×300×950
1050×350×1050
1050×350×1050
32.6/37.2
32.7/37.3
1050×55×1050
1050×55×1050
1115×100×1115
1115×100×1115
7.4/9.7
7.4/9.7
R410A/R32
4.4/2.6
9.52/15.9
9.52/19.1
OD 25
Notes: 1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. 2. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. 3. Air flow rate are from the highest speed to the lowest speed, total 7 rates for each model. 4. Sound pressure level is from highest level to lowest level, total 7 levels for each model. Sound pressure level is measured 1.5m below the unit in a semi-anechoic chamber. 5. The dimension is only the body size, excluding the size of the installation lug, connecting copper pipe, etc. For detailed dimensions, please refer to the installation manual. 6. Exposed height of the panel after being installed on the ceiling.
5
Grandezze D28 ÷ D140 – (unit: mm)
Dimensions
Four-way Cassette dimensions
Four-way Cassette piping connections
MODEL
A
B
C
D
F
E
D28 ÷ D56
204
141
63
41.5
12.7
6.35
D71 ÷ D90
246
163
103
41.5
15.9
9.52
D100 ÷ D140
288
190
103
56.5
15.9
9.52
6
Dimensions
Grandezze D160 ÷ D180 (unit: mm)
MODEL
A
D160
300
D180
300
B
C
D
200
9.52
15.9
200
9.52
19.1
7
Unit Placement
Placement Considerations Unit placement should take account of the following considerations: · Units should not be installed in the following locations:
· A place filled with mineral oil, fumes or mist, like a kitchen. · A place where there are corrosive gases, such as acid or alkaline gases. · A place exposed to combustible gases and using volatile combustible gases such as diluent or gasoline. · A place where there is equipment emitting electromagnetic radiation. · A place where there is a high salt content in the air like a coast. · Do not use the air conditioner in an environment where an explosion may occur. · Places like in vehicles or cabin rooms. · Factories with major voltage fluctuations in the power supplies. · Other special environmental conditions. · Units should be installed in positions where: · Ensure that the airflow in and out of the IDU is reasonably organized to form an air circulation in the room. · Ensure IDU maintenance space. · The nearer the drainage pipe and copper pipe are to the ODU, the lower the pipe cost is. · Prevent the air conditioner from blowing directly to the human body. · The closer the wiring to the power cabinet, the lower the wiring cost is. · Keep the air-conditioning return air away from the setting sun of the room. · Be careful not to interfere with the light tank, fire pipe, gas pipe and other facilities. · The IDU should not be lifted in the places like load-bearing beam and columns that affect the structural safety of the house. · The wired controller and the IDU should be in the same installation space; otherwise, the sampling point setting of the wired con-
troller need to be changed.
Space Requirements
1. The centerline of the maintenance hole should be in the same position as the centerline of the indoor unit. 2. The dimensions of A are shown in Table 2,1
8
Piping Diagram
LEGEND 1 2 3 4
T1
Inlet Air Temp. Sensor
T2A
Liquid Pipe Temp. Sensor
T2
Middle Pipe Temp. Sensor
T2B
Gas Pipe Temp. Sensor
9
Wiring Diagram
10
Notes for installers and service engineers
Caution · All installation , servicing and maintenance must be carried out by competent and suitably qualified, certified and accredited profes-
sionals and in accordance with all applicable legislation. · Units should be grounded in accordance with all applicable legislation . Metal and other conductive components should be insula-
ted in accordance with all applicable legislation. · Power supply wiring should be securely fastened at the power supply terminals – loose power supply wiring would represent a fire
risk. · After installation, servicing or maintenance, the electric control box cover should be closed. Failing to close the electric control box
cover risks fire or electric shock. · The dotted lines indicate the field wiring or optional function · D1D2 communication ports are used for group control communication. When connecting the group controller, the D1D2 port of the
indoor units that are to be group controlled must be connected in daisy chain, and the group controller must be connected to the X1X2 port of one of the indoor units in the group control, and set to group control mode. In addition, D1D2 communication ports can also be connected to the central controller.
11
Cooling Capacity Table
Capacity Tables
MODEL
Q4DN-3-XY D28 Q4DN-3-XY D36 Q4DN-3-XY D45 Q4DN-3-XY D56 Q4DN-3-XY D71 Q4DN-3-XY D80 Q4DN-3-XY D90 Q4DN-3-XY D100 Q4DN-3-XY D112 Q4DN-3-XY D140 Q4DN-3-XY D160 Q4DN-3-XY D180
14/20
TC
SC
2.5
2.4
3.2
3.1
4.0
3.6
5.0
4.5
6.3
5.7
7.1
6.6
8.0
7.2
8.9
8.1
9.9
9.1
12.4
11.0
14.2 12.6
15.9
14.1
Abbreviations: TC: Total capacity (kW) SC: Sensible capacity(kW)
Notes: 1.Shaded cells indicate rating condition.
16/23
TC
SC
2.7
2.5
3.4
3.1
4.3
3.8
5.3
4.6
6.7
5.8
7.6
6.7
8.5
7.4
9.5
8.4
10.6
9.3
13.2
11.4
15.1
13.0
17.0
14.7
Indoor air temperature (°C WB/DB)
18/26
19/27
20/28
TC
SC
TC
SC
TC
SC
2.8
2.5
2.8
2.4
2.9
2.3
3.6
3.2
3.6
3.0
3.7
3.0
4.5
3.8
4.5
3.7
4.6
3.6
5.6
4.7
5.6
4.6
5.7
4.5
7.0
5.9
7.1
5.8
7.2
5.6
7.9
6.8
8.0
6.6
8.1
6.4
8.9
7.5
9.0
7.3
9.1
7.1
9.9
8.4
10.0
8.2
10.1
7.9
11.1
9.4
11.2
9.2
11.3
8.9
13.8
11.5
14.0
11.3
14.2
11.0
15.8 13.2 16.0 12.9 16.2 12.5
17.8
14.8
18.0
14.5
18.2
14.1
22/30
TC
SC
2.9
2.2
3.8
2.8
4.7
3.4
5.8
4.2
7.4
5.4
8.3
6.1
9.4
6.8
10.4
7.6
11.6
8.4
14.5 10.5
16.6 12.0
18.7 13.5
24/32
TC
SC
3.0
2.1
3.9
2.7
4.8
3.3
6.0
4.1
7.6
5.2
8.5
5.8
9.6
6.5
10.6
7.2
11.9
8.1
14.9
10.1
17.0
11.5
19.1
12.9
Heating Capacity Table
Indoor air temperature (°C DB)
MODEL
16
18
20
21
22
24
TC
TC
TC
TC
TC
TC
Q4DN-3-XY D28
3.4
3.4
3.2
3.1
3.0
2.8
Q4DN-3-XY D36
4.2
4.2
4.0
3.8
3.8
3.5
Q4DN-3-XY D45
5.3
5.3
5.0
4.8
4.7
4.4
Q4DN-3-XY D56
6.7
6.6
6.3
6.1
5.9
5.5
Q4DN-3-XY D71
8.5
8.4
8.0
7.8
7.5
7.0
Q4DN-3-XY D80
9.5
9.5
9.0
8.7
8.5
7.8
Q4DN-3-XY D90
10.6
10.5
10.0
9.7
9.4
8.8
Q4DN-3-XY D100
11.9
11.8
11.2
10.9
10.5
9.8
Q4DN-3-XY D112
13.3
13.1
12.5
12.1
11.8
10.9
Q4DN-3-XY D140
17.0
16.8
16.0
15.5
15.0
13.9
Q4DN-3-XY D160
19.1
19.1
18.0
17.4
16.9
15.8
Q4DN-3-XY D180
21.3
21.3
20.0
19.4
18.8
17.5
Abbreviations: TC: Total capacity (kW)
Notes: 1.Shaded cells indicate rating condition.
12
Electrical characteristics
MODEL Hz
Q4DN-3-XY D28
50
Q4DN-3-XY D36
50
Q4DN-3-XY D45
50
Q4DN-3-XY D56
50
Q4DN-3-XY D71
50
Q4DN-3-XY D80
50
Q4DN-3-XY D90
50
Q4DN-3-XY D100
50
Q4DN-3-XY D112
50
Q4DN-3-XY D140
50
Q4DN-3-XY D160
50
Q4DN-3-XY D180
50
Volts
220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240
Power supply
Min. volts Max. volts
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
MCA
0.51 0.51 0.59 0.59 0.94 1.05 1.09 0.95 1.18 1.41 2.30 2.73
MFA
15 15 15 15 15 15 15 15 15 15 15 15
Indoor fan motors
Rated motor output (kW)
FLA
0.045
0.41
0.045
0.41
0.045
0.47
0.045
0.47
0.125
0.75
0.125
0.84
0.125
0.87
0.125
0.76
0.125
0.94
0.125
1.13
0.125
1.83
0.125
2.10
Abbreviations: MCA: Minimum Circuit Amps MFA: Maximum Fuse Amps FLA: Full Load Amps
Notes: Voltage range: Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed range limits. Maximum allowable voltage variation between phases is 2%. Selection wire size based on the value of MCA. MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth circuit breaker).
13
Sound Level
Overall
MODEL
Sound pressure levels dB
SSH SH H
M
L
SL SSL
Q4DN-3-XY D28 30 29 28 27 26.5 26 25
Q4DN-3-XY D36 30 29 28 27 26.5 26 25
Q4DN-3-XY D45 33 32 31 30 29 28 27
Q4DN-3-XY D56 33 32 31 30 29 28 27
Q4DN-3-XY D71 37 36 34 33 32 30 29
Q4DN-3-XY D80 38 37 35 34 32 31 29
Q4DN-3-XY D90 38 37 35 34 32 31 29
Q4DN-3-XY D100 39 38 37 36 35 34 33
Q4DN-3-XY D112 41 40 38 37 36 34 33
Q4DN-3-XY D140 43 42 40 39 37 36 34
Q4DN-3-XY D160 48 46 44 43 41 39 37
Q4DN-3-XY D180 52 49 47 45 42 39 38
Notes: 1. Sound pressure levels are measured 1.5m below the unit in a semi-anechoic chamber at 0 Pa. During in-situ operation, sound pressure levels may be higher as a result of ambient noise.
Octave Band Levels
Q4DN-3-XY D28
Q4DN-3-XY D36
Q4DN-3-XY D45
Q4DN-3-XY D56
14
Sound Level
Q4DN-3-XY D71
Q4DN-3-XY D90
Q4DN-3-XY D112
Q4DN-3-XY D160
Q4DN-3-XY D80 Q4DN-3-XY D100
Q4DN-3-XY D140 Q4DN-3-XY D180
15
Temperature and Airflow Distributions
Simulate condition
MODEL NAME Room size (m)
Q4DN-3-XY D28 Q4DN-3-XY D36 Q4DN-3-XY D45 Q4DN-3-XY D56 Q4DN-3-XY D71 Q4DN-3-XY D80 Q4DN-3-XY D90 Q4DN-3-XY D100 Q4DN-3-XY D112 Q4DN-3-XY D140 Q4DN-3-XY D160 Q4DN-3-XY D180
6×6 6×6 6×6 8×8 8×8 8×8 10×10 10×10 10×10 10×10 10×10 10×10
Ceiling height (m)
2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7
Flow angle (Cooling/Hea-
ting) 30°/65° 30°/65° 30°/65° 30°/65° 30°/65° 30°/65° 30°/65° 30°/65° 30°/65° 30°/65° 30°/65° 30°/65°
Placing
Center Center Center Center Center Center Center Center Center Center Center Center
Note: 1. These figures and videos are based on software simulation. They show typical temperature and airflow distributions in the conditions above. In the actual installation, they may differ from these figures and videos under the influence of air temperature conditions, ceiling height, cooling/heating load, obstacles, etc.
Airflow distributions – Cooling (after 300s)
Q4DN-3-XY D28
Q4DN-3-XY D36
Q4DN-3-XY D45
Q4DN-3-XY D56
Q4DN-3-XY D71
Q4DN-3-XY D80
16
Temperature and Airflow Distributions
Q4DN-3-XY D90
Q4DN-3-XY D100
Q4DN-3-XY D112 Q4DN-3-XY D160
Q4DN-3-XY D140 Q4DN-3-XY D180
17
Temperature and Airflow Distributions
Airflow distributions – Heating (after 300s)
Q4DN-3-XY D28
Q4DN-3-XY D36
Q4DN-3-XY D45
Q4DN-3-XY D56
Q4DN-3-XY D71
Q4DN-3-XY D80
Q4DN-3-XY D90
Q4DN-3-XY D100
18
Temperature and Airflow Distributions
Q4DN-3-XY D112
Q4DN-3-XY D140
Q4DN-3-XY D160
Q4DN-3-XY D180
19
Temperature distributions – Cooling (after 300s)
Q4DN-3-XY D28
Q4DN-3-XY D36
Q4DN-3-XY D45
Q4DN-3-XY D56
Q4DN-3-XY D71
Q4DN-3-XY D80
Q4DN-3-XY D90
Q4DN-3-XY D100
20
Q4DN-3-XY D112 Q4DN-3-XY D160
Q4DN-3-XY D140 Q4DN-3-XY D180
21
Temperature distributions – Heating (after 300s)
Q4DN-3-XY D28
Q4DN-3-XY D36
Q4DN-3-XY D45
Q4DN-3-XY D56
Q4DN-3-XY D71
Q4DN-3-XY D80
Q4DN-3-XY D90
Q4DN-3-XY D100
22
Q4DN-3-XY D112 Q4DN-3-XY D160
Q4DN-3-XY D140 Q4DN-3-XY D180
23
FOR 30 YEARS WE HAVE BEEN OFFERING SOLUTIONS FOR SUSTAINABLE COMFORT AND THE WELL-BEING OF PEOPLE AND THE ENVIRONMENT
www.clivet.com
sales and service
SCRE 4W-Liwnaey4-ic -assWetDtAeN–iQK4DMNF-3-BXTY21ID02083-I–D01240 – BT23N009GB–00
.CLIVET S.p.A
Via Camp Lonc 25, Z.I. Villapaiera 32032 – Feltre (BL) – Italy Tel. +39 0439 3131 – info@clivet.it
CLIVET GMBH
Hummelsbütteler Steindamm 84, 22851 Norderstedt, Germany Tel. +49 40 325957-0 – info.de@clivet.com
Clivet Group UK LTD
Units F5 & F6 Railway Triangle, Portsmouth, Hampshire PO6 1TG Tel. +44 02392 381235 Enquiries@Clivetgroup.co.uk
CLIVET LLC
Office 508-511, Elektozavodskaya st. 24, Moscow, Russian Federation, 107023 Tel. +7495 6462009 – info.ru@clivet.com
Clivet South East Europe
Jaruscica 9b 10000, Zagreb, Croatia
Tel. +3851 222 8784 – info.see@clivet.com
CLIVET MIDEAST FZCO
Dubai Silicon Oasis (DSO) Headquarter Building, Office EG-05, P.O Box-342009, Dubai, UAE Tel. +9714 3208499 – info@clivet.ae
CLIVET France
10, rue du Fort de Saint Cyr – 78180 Montigny le Bretonneux, France
info.fr@clivet.com
Clivet Airconditioning Systems Pvt Ltd
Office No.501 & 502,5th Floor, Commercial I, Kohinoor City, Old Premier Compound, Off LBS
Marg, Kirol Road, Kurla West, Mumbai
Maharashtra 400070, India
Tel. +91 22 30930200 – sales.india@clivet.com
Documents / Resources
![]() | CLIveT D140 4 Way Cassette [pdf] Instruction Manual D140 4 Way Cassette, D140, 4 Way Cassette, Cassette |