User Manual for DALC NET models including: LINE-5CV-DMX Voltage Output For Strip LED and LED Module, LINE-5CV-DMX, Voltage Output For Strip LED and LED Module, Strip LED and LED Module, LED Module
LINE-5CV-DMX
Search
LINE 5CV DMX Device Manual Made in Italy DALCNET S.r.l. 36077 Altavilla Vicentina (VI) – Italy Via Lago di Garda, 22 Tel. 39 0444 1836680
File Info : application/pdf, 18 Pages, 1.05MB
DocumentDocumentLINE 5CV DMX
Device Manual
Made in Italy
FEATURES
DIMMER LED Power Supply: 12-24-48 Vdc Voltage Output for strip LED and LED module WHITE, MONOCOLOR, DYNAMIC WHITE, RGB, RGB+W, RGB+WW and RGB+TW Light Control BUS command:: DMX512-A+RDM Device configuration using Dalcnet LightApp mobile application Uscite in tensione costante per carichi R PWM modulation from 300 to 4000 Hz Parameters that can be set from APP and via RDM:
o PWM Frequency o Adjustment curve o Power On Levels o Personality DMX Indication of operating hours and ignition cycles Short-circuit protection on LED outputs Opto-Isolated DMX Input Soft on/off Soft brightness dimming Extended temperature range 100% Functional test
PRODUCT DESCRIPTION
LINE-5CV-DMX is a 5-channel output LED dimmer, which can be controlled by means of a DMX BUS control. The LED dimmer is suitable for driving loads such as StripLEDs and LED modules, White, Single-color, Dynamic White, RGB, RGB+W, RGB+WW and RGB+TW at constant voltage. A 12-24-48 Vdc power supply can be connected. The maximum output current is 12A. The dimmerLED has the following protections: short-circuit protection on the LED outputs, over-power protection, reverse polarity protection, and input fuse protection.
Through the Dalcnet LightApp mobile application it is possible to configure multiple parameters of the LINE-5CV-DMX such as dimming frequency, dimming curve, max and min brightness level, etc. LightApp can be downloaded free of charge from the Apple App Store and Google Play Store.
For the most up-to-date manual, please visit our website: www.dalcnet.com or the QR Code directly on your device.
DALCNET S.r.l. 36077 Altavilla Vicentina (VI) Italy Via Lago di Garda, 22
Tel. +39 0444 1836680 www.dalcnet.com info@dalcnet.com
Rev. 08/04/2024 - Pag. 1/18
LINE 5CV DMX
Device Manual
Made in Italy
PRODUCT CODE
CODE LINE-5CV-DMX
POWER SUPPLY 12-24-48 VDC
OUTPUT LED N° OF CHANNEL
5 x 5A (max 12A)1
5
BUS COMMAND DMX512-RDM
APP CONFIG APP: LIGHT APP
PROTECTIONS
OVP Over-voltage protection2
RVP Reverse polarity protection2
IFP Protection with input fuse2
SCP Short circuit protection
REFERENCE STANDARDS
EN 55015
EN 61547 EN 61347-1 EN 61347-2-13
ANSI E1.11
ANSI E1.20
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment Equipment for general lighting purposes EMC immunity requirement Lamp Controlgear Part 1: General and safety requirement Lamp Controlgear Part 2-13: Particular requirement for d.c. or a.c. supplied electronic Controlgear for LED modules Entertainment Technology - USITT DMX512-A - Asynchronous Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories Entertainment Technology-RDM-Remote Device Management over USITT DMX512 Networks
1 The maximum output current depends on the operating conditions and the ambient temperature of the installation. For the
correct configuration, check the maximum power that can be delivered in the "Specifiche Tecniche" section. 2 Protections refer to the control logic of the board.
DALCNET S.r.l. 36077 Altavilla Vicentina (VI) Italy Via Lago di Garda, 22
Tel. +39 0444 1836680 www.dalcnet.com info@dalcnet.com
Rev. 08/04/2024 - Pag. 2/18
LINE 5CV DMX
Device Manual
Made in Italy
TECHNICAL SPECIFICATIONS
DC voltage range
Output voltage
Supply current
Output current3
12 Vdc
Nominal power
24 Vdc
48 Vdc
Power loss in standby mode
Type of loads4
Dimming curves5
Dimming method
PWM Frequency5
PWM Resolution
Storage Temperature
Working ambient temperature, Ta3
Type of connector
Wiring section
Solid Size Stranded Size
Wire strip length
IP protection grade
Casing Material
Packaging units (pieces/units)
Mechanical dimensions
Packaging dimensions
Weight
LINE 5CV DMX
Min: 10,8Vdc Max: 52,8Vdc
=Vin
Max 12A
5x max 5A
max 12A Totali
60W
144W Tot.
120W
288W Tot
240W
576W Tot.
< 0,5W
R
Linear Quadratic Exponential
Pulse Width Modulation "PWM"
307 667 1333 2000 4000 Hz
16bit
Min: -40°C Max: 60°C
Min: -10°C Max: 60°C
Morsetti Push-In
0,2 ÷ 1,5 mm2 / 24 ÷ 16 AWG
9 ÷ 10 mm IP20
Plastica 1pz
186 x 29 x 21 mm 197 x 34 x 29 mm
80g
3 These maximum current values can only be applied under conditions of adequate ventilation. 4 Type of load: Resistive and DC/DC Converter.
5 The parameters are configured via LIGHTAPP.
DALCNET S.r.l.
Tel. +39 0444 1836680
36077 Altavilla Vicentina (VI) Italy
www.dalcnet.com info@dalcnet.com
Via Lago di Garda, 22
Rev. 08/04/2024 - Pag. 3/18
LINE 5CV DMX
Device Manual
Made in Italy
WIRING DIAGRAM
Follow the steps below for product installation as shown in the connection diagram:
· Load connection: connect the LED load positive to terminal "L" with the "+" symbol, instead of the LED load negatives to terminals "L1", "L2", "L3", "L4" and "L5" with the "-" symbol.
· DMX-RDM BUS connection: connect the DATA+, DATA- and COM signal respectively to the "DMX" terminals with the "D+" "D-" "COM" symbols. Be sure not to connect live parts to the "INPUT" terminals.
· Supply connection: connect a 12-24-48 Vdc constant voltage SELV power supply (depending on the technical characteristics of the LED load) to the DC IN terminal with the "+" and "- " symbols. Make sure that you are not using a power supply with a constant current output and check that the polarity of the cables is correct.
CONNECTION DIAGRAM: PERSONALITY DIMMER & MACRO DIMMER UP TO 5 WHITE OR MONOCHROME LOADS
CONNECTION DIAGRAM: PERSONALITY DIM TO WARM & DYNAMIC WHITE UP TO 2 LOADS DIM TO WARM OR DYNAMIC WHITE
DALCNET S.r.l. 36077 Altavilla Vicentina (VI) Italy Via Lago di Garda, 22
Tel. +39 0444 1836680 www.dalcnet.com info@dalcnet.com
Rev. 08/04/2024 - Pag. 4/18
LINE 5CV DMX
Device Manual
Made in Italy
PERSONALITY CONNECTION DIAGRAM: SMART HSI RGB & RGB & M+RGB+STROBE CARICHI RGB
PERSONALITY CONNECTION DIAGRAM: SMART HSI RGBW & RGBW & M+RGBW+STROBE RGB+W LOADS
PERSONALITY CONNECTION DIAGRAM: SMART RGB+TW & RGB+TW LOADS
DALCNET S.r.l. 36077 Altavilla Vicentina (VI) Italy Via Lago di Garda, 22
Tel. +39 0444 1836680 www.dalcnet.com info@dalcnet.com
Rev. 08/04/2024 - Pag. 5/18
LINE 5CV DMX
Device Manual
FLICKER PERFORMANCE
Made in Italy
Thanks to its 4kHz dimming frequency, the LINE-5CV-DMX effectively reduces the occurrence of the Flicker phenomenon. Depending on an individual's sensitivity and the nature of their activities, flickering can impact one's well-being, even if the changes in luminance are beyond the threshold detectable by the human eye.
The graph shows the phenomenon of Flickering in function at the frequency, measured throughout the dimming range. The results show the low-risk zone (yellow) and the noeffect zone (green). Defined by IEEE 1789-20156
DIMMING CURVE
Output power [%]
100 90 80 70 60 50 40 30 20 10 0 0
Exponential Linear Quadratic
10 20 30 40 50 60 70 80 90 100 Dimming Level [%]
6 Institute of Electrical and Electronics Engineers (IEEE). IEEE std 1789: Recommended Practices for Modulating Current in High-
Brightness LEDs for Mitigating Health Risks to Viewers.
DALCNET S.r.l. 36077 Altavilla Vicentina (VI) Italy Via Lago di Garda, 22
Tel. +39 0444 1836680 www.dalcnet.com info@dalcnet.com
Rev. 08/04/2024 - Pag. 6/18
LINE 5CV DMX
Device Manual
Made in Italy
DMX+RDM BUS OPERATION
WITH THE DMX+RDM "SLAVE" BUS MODE, THE OUTPUTS ARE MANAGED VIA AN EXTERNAL DMX CONTROL.
REFERENCE STANDARDS FOR THE DMX512+RDM BUS
ANSI E1.11 ANSI E1.20
Entertainment Technology - USITT DMX512-A - Asynchronous Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories Entertainment Technology-RDM-Remote Device Management over USITT DMX512 Networks
PIN OUT 3 AND 5 PIN XLR CONNECTORS
USE Common Reference
Primary Data Link
Secondary Data Link (Optional see clause 4.8 of ANSI E1.11)
3-PIN XLR Pin # 1 2 3
5-PIN XLR Pin # 1 2 3 4 5
DMX512 Function Data Link Common Data 1Data 1+ Data 2Data 2+
DALCNET S.r.l. 36077 Altavilla Vicentina (VI) Italy Via Lago di Garda, 22
Tel. +39 0444 1836680 www.dalcnet.com info@dalcnet.com
Rev. 08/04/2024 - Pag. 7/18
LINE 5CV DMX
Device Manual
CHANNELS MAP DMX512-RDM
DIMMER DMX
CHANNEL 1 2 3 4 5
FUNCTION
DIMMER 1 DIMMER 2 DIMMER 3 DIMMER 4 DIMMER 5
DMX LEVEL 0...255 DMX LEVEL 0...255 DMX LEVEL 0...255 DMX LEVEL 0...255 DMX LEVEL 0...255
Made in Italy
MACRO CANALE
DMX FUNCTION
CHANNEL
1
MACRO DIMMER
DIM TO WARM
DMX CHANNEL
FUNCTION
1
DIM TO WARM 1
2
DIM TO WARM 2
DMX LEVEL 0...255
DMX LEVEL 0...255 DMX LEVEL 0...255
BIANCO DINAMICO
DMX CHANNEL
FUNCTION
1
DIMMER 1
2
CORREZIONE TEMP. COLORE 1
3
DIMMER 2
4
CORREZIONE
TEMP. COLORE 2
DMX LEVEL 0...255 DMX LEVEL 0...255 DMX LEVEL 0...255 DMX LEVEL 0...255
SMART HSI RGB / SMART HSI RGBW
DMX CHANNEL
FUNCTION
MASTER
1
DIMMER
DMX LEVEL 0...255
CORREZIONE 2
TEMP. COLORE
DMX LEVEL 0...255
3
HUE
DMX LEVEL 0...255
HUE ROTATION Hue Fine Hold 30min 15min 6min
3min
1min
30s
15s
6s
3s
4
(RAINBOW) TIME
0...15 16...25 26...51 52...76 77...102 103...127 128...153 154...179 180...204 205...230 231...255
5
SATURAZIONE
DMX LEVEL 0...255
6
STROBO RATE
Fix Blackout 1fps 2fps 3fps 4fps 5fps
6fps
7fps
8fps
9fps
10fps 12fps 14fps 16 fps
Fix
0...15 16...31 32...47 48...63 64...79 80...95 96...111 112...127 128...143 144...159 160...175 176...191 192...207 208...223 224...239 240...255
DALCNET S.r.l. 36077 Altavilla Vicentina (VI) Italy Via Lago di Garda, 22
Tel. +39 0444 1836680 www.dalcnet.com info@dalcnet.com
Rev. 08/04/2024 - Pag. 8/18
LINE 5CV DMX
Device Manual
Made in Italy
SMART HSI RGB+TW
DMX CHANNEL
FUNCTION
MASTER 1
DIMMER RGB
2
HUE
DMX LEVEL 0...255 DMX LEVEL 0...255
3
HUE ROTATION (RAINBOW)
Hue Fine
Hold
30min
15min
6min
3min
1min
30s
15s
6s
3s
TIME
0...15 16...25 26...51 52...76 77...102 103...127 128...153 154...179 180...204 205...230 231...255
4
DIMMER TW
CORREZIONE 5
TEMP. COLORE
DMX LEVEL 0...255 DMX LEVEL 0...255
6
CCT ROTATION Hue Fine Hold
60min 30min 12min
6min
2min
1min
30s
12s
6s
0...15 16...25 26...51 52...76 77...102 103...127 128...153 154...179 180...204 205...230 231...255
RGB DMX
CHANNEL
1 2 3
FUNCTION
DIMMER ROSSO DIMMER VERDE
DIMMER BLU
DMX LEVEL 0...255 DMX LEVEL 0...255 DMX LEVEL 0...255
RGBW
DMX CHANNEL
FUNCTION
1
DIMMER ROSSO
2
DIMMER VERDE
3
DIMMER BLU
4
DIMMER BIANCO
DMX LEVEL 0...255 DMX LEVEL 0...255 DMX LEVEL 0...255 DMX LEVEL 0...255
M+RGB+S DMX
CHANNEL
FUNCTION
1
MASTER DIMMER
2
DIMMER ROSSO
3
DIMMER VERDE
4
DIMMER BLU
5
STROBO
DMX LEVEL 0...255 DMX LEVEL 0...255 DMX LEVEL 0...255
DMX LEVEL 0...255 Fix Blackout 1fps 2fps 3fps 4fps 5fps 6fps 7fps 8fps 9fps 10fps 12fps 14fps 16fps Fix
M+RGBW+S
DMX CHANNEL
FUNCTION
1
MASTER DIMMER
2
DIMMER ROSSO
3
DIMMER VERDE
4
DIMMER BLU
5
DIMMER BIANCO
6
STROBO
DMX LEVEL 0...255 DMX LEVEL 0...255 DMX LEVEL 0...255 DMX LEVEL 0...255 DMX LEVEL 0...255 Fix Blackout 1fps 2fps 3fps 4fps 5fps 6fps 7fps 8fps 9fps 10fps 12fps 14fps 16fps Fix
DALCNET S.r.l. 36077 Altavilla Vicentina (VI) Italy Via Lago di Garda, 22
Tel. +39 0444 1836680 www.dalcnet.com info@dalcnet.com
Rev. 08/04/2024 - Pag. 9/18
LINE 5CV DMX
Device Manual
Made in Italy
RDM SETTINGS
DMX START ADDRESS: DEVICE DMX CHANNEL SETTING.
Within the DMX START ADDRESS configuration, you can configure the DMX channel of the device.
DMX PERSONALITY: DEVICE MAP SETTINGS
Within the DMX PERSONALITY configuration it is possible to select the various maps of the LINE 5CV DMX, including: o MACRO DIMMER o DIM TO WARM o TUNABEL WHITE o SMART HSI RGB o SMART HSI RGBW o RGB o RGBW o MRGB+S o MRGBW+S o DIMMER o SMART HSI RGBW+TW
DEVICE STATE: DEVICE OPERATION STATUS SETTINGS
Within the DEVICE STATE menu there is information on the operating hours and the on/off cycles of the device. These parameters are read-only and cannot be edited.
LAMP MENU: DEVICE POWER-ON STATUS SETTINGS
Within the LAMP MENU' menu it is possible to define "LAMP ON MODE", i.e. the status of the outputs when the device is switched on, whether it is 100% On or Off. This function is only enabled in the absence of the DMX signal.
DIMMER MENU: DIMMING CURVE AND FREQUENCY SETTINGS OF THE DEVICE
Within the DIMMER MENU you can select the Linear, Quadratic or Exponential dimming curve and the dimming frequency 307, 667, 1333, 2000 or 4000 Hz.
DALCNET S.r.l. 36077 Altavilla Vicentina (VI) Italy Via Lago di Garda, 22
Tel. +39 0444 1836680 www.dalcnet.com info@dalcnet.com
Rev. 08/04/2024 - Pag. 10/18
LINE 5CV DMX
Device Manual
Made in Italy
RDM COMMANDS
REQUESTED PARAMETERS
DISC_UNIQUE_BRANCH
DISC_MUTE
DISC_UN_MUTE
SUPPORTED_PARAMETERS
PARAMETER_DESCRIPTION
DEVICE_INVO
DMX_START_ADDRESS
IDENTIFY_DEVICE
MECHANICAL DIMENSIONS
SUPPORTED PARAMETERS
PRODUCT_DETAIL_ID_LIST
DEVICE_MODEL_DESCRIPTION
MANUFACTURER_LABEL
DEVICE LABEL
BOOT_SOFWARE_VERSION_ID
BOOT_SOFWARE_VERSION_LABEL
DMX_PERSONALITY
DMX_PERSONALITY_DECRIPTION
SLOT_INFO
SLOT_DESCRIPTION
DEFAULT_SLOT_VALUE
DEVICE_HOURS
LAMP_ON_MODE
DIMMER_INFO
CURVE
CURVE_DESCRIPTION
MODULATION_FREQUENCY
MODULATION_FREQUENCY_DESCRIPTION
DALCNET S.r.l. 36077 Altavilla Vicentina (VI) Italy Via Lago di Garda, 22
Tel. +39 0444 1836680 www.dalcnet.com info@dalcnet.com
Rev. 08/04/2024 - Pag. 11/18
LINE 5CV DMX
Device Manual
Made in Italy
TECHNICAL NOTE
iNSTALLATION · CAUTION: The product may only be connected and installed by a qualified electrician. All applicable regulations, legislation, and building codes must be observed. Incorrect installation of the product can cause irreparable damage to the product and the connected LEDs. Use caution when connecting LEDs. Polarity reversal results in no light output and can often damage the LEDs. · Maintenance must only be carried out by qualified personnel in compliance with current regulations. The product is designed and intended to operate LED loads only. Powering non-LED loads may push the product outside its specified design limits and is, therefore, not covered by any warranty. Operating conditions of the product may never exceed the specifications as per the product datasheet. · The product must be installed inside a switchgear/controlgear cabinet and/or junction box protection against overvoltage. · The product must be installed in a vertical or horizontal position with the label/top cover facing upwards or vertically. Oth er positions are not permitted. The bottom position is not permitted (label/top cover facing down). · Keep separated 230Vac (LV) circuits and not SELV circuit from safety extra low voltage (SELV) circuit and from any connection with this product. It is absolutely forbitten to connect, for any reason whatsoever, directly or indirectly, the 230Vac mains voltage to the product (terminal block of BUS included). · The product must be dissipated correctly. · The use of the product in harsh environments could limit the output power. · For built-in components inside luminaires, the ta ambient temperature range is a guideline given for the optimum operating environment. However, integrator must always ensure proper thermal management (i.e. correct mounting of the device, air flow etc.) so that the tc point temperature does not exceed the tc maximum limit in any circumstance. Reliable operation and lifetime is only guaranteed if the maximum tc point temperature is not exceeded under the conditions of use.
POWER SUPPLY · Only use SELV power supplies with limited current for device power supply, short circuit protection and the power must be dimensioned correctly. In the case of power supplies equipped with ground terminals, it is mandatory to connect ALL protective ground points (PE= Pr otection Earth) to a properly and certified protection earth. · The connection cables between the very low voltage power source and the product must be properly dimensioned and must be insu lated from any wiring or part at non-SELV voltage. Use double insulated cables. · Dimension the power of the power supply in relation to the load connected to the device. In case the power supply is oversized compared to the maximum absorbed current, insert a protection against over-current between the power supply and the device.
COMMANDS: · The length of the cables connecting between the local commands (N.O. Push button or other) and the product must be less than 10m. The cables must be properly dimensioned and must be insulated from any non-SELV wiring or voltage. It is recommended to use double insulated cables, if deemed appropriate also shielded. · All devices and control signals connected to the buses (DMX512 or other) must be of the SELV type (the connected devices must be SELV or in any case provide a SELV signal).
OUTPUTS: · It is recommended that the length of the connection cables between the product and the LED module is less than 3m. Cables must be properly sized and should be insulated from any non-SELV wiring or parts. It is recommended to use double-insulated cables. If you want to use connection cables between the product and the LED module longer than 3m, the installer must ensure the correct operati on of the system. In any case, the connection between the product and the LED module must not exceed 30m.
DALCNET S.r.l. 36077 Altavilla Vicentina (VI) Italy Via Lago di Garda, 22
Tel. +39 0444 1836680 www.dalcnet.com info@dalcnet.com
Rev. 08/04/2024 - Pag. 12/18
SYMBOLOGIES
LINE 5CV DMX
Device Manual
Made in Italy
All products are manufactured in compliance with European Directives, as reported in the EU Conformity Declaration.
Independent lamp Controlgear: lamp controlgear consisting of one or more separate elements so designed that it can be mounted separately outside a luminaire, with protection according to the marking of the lamp controlgear and without any additional enclosure
"Safety Extra Low Voltage" in a circuit which is isolated from the mains supply by insulation not less than that between the primary and secondary circuits of a safety isolating transformer according to IEC 61558-2-6. At the end of its useful life the product described in this datasheet is classified as waste from electronic equipment, and cannot be disposed together with the municipal undifferentiated solid waste. Warning! Incorrect disposal of this product may cause serious damage to the environment and human health. Please be informed about the correct disposal procedures for waste collecting and processing provided by local authorities.
DALCNET S.r.l. 36077 Altavilla Vicentina (VI) Italy Via Lago di Garda, 22
Tel. +39 0444 1836680 www.dalcnet.com info@dalcnet.com
Rev. 08/04/2024 - Pag. 13/18
LINE 5CV DMX
Device Manual
LIGHTAPP START-UP AND FIRST INSTALLATION
Made in Italy
STARTUP SCREEN
On this screen, the app waits for the device parameters to be read.
To read the parameters, simply bring the back of the smartphone close to the device's label. The read-sensitive zone of the smartphone may vary depending on the model. Once the connection is established, a quick loading screen will appear. You must remain in position with your smartphone until the parameters are fully loaded.
iOS variant: To read the parameters, you need to press the SCAN button at the top right. A pop-up will appear indicating when your smartphone is ready to scan. Move the smartphone closer to the device and remain in place until the parameters are fully loaded.
DALCNET S.r.l. 36077 Altavilla Vicentina (VI) Italy Via Lago di Garda, 22
Tel. +39 0444 1836680 www.dalcnet.com info@dalcnet.com
Rev. 08/04/2024 - Pag. 14/18
LINE 5CV DMX
Device Manual
SETTINGS AND FIRMWARE LOADING SCREENS
SETTINGS
On the settings page you can set:
App language Password: To be used for writing parameters.
Made in Italy
FIRMWARE
On the firmware page, you can update the firmware of the device.
The requested file must be of type *.bin.
Once the file is uploaded, follow the on-screen instructions.
ATTENTION: Once the procedure has begun, it is irrevocable and it is not possible to pause it. In case of interruption the firmware would be corrupted. In this case the device will need to repeat the loading procedure. At the end of the firmware loading, all previously set parameters will be reset to factory values.
If the update is successful and the loaded version is different from the previous one, the device will make 10 flashes
DALCNET S.r.l. 36077 Altavilla Vicentina (VI) Italy Via Lago di Garda, 22
Tel. +39 0444 1836680 www.dalcnet.com info@dalcnet.com
Rev. 08/04/2024 - Pag. 15/18
LINE 5CV DMX
Device Manual
Made in Italy
LOADING PARAMETERS
IMPORTANT: The writing of the parameters must be done with the device off (without input power).
READ
With the app in READ mode, the smartphone will scan the device and show its current configuration on the screen.
WRITE
With the app in WRITE mode, the smartphone will write the configuration of the parameters set on the screen inside the device.
Write all In normal mode (Write All Off) the app writes only the parameters that have changed since the previous reading. In this mode, writing will only be successful if the serial number of the device matches the one previously read.
In Write All mode, all parameters are written. In this mode, writing will be successful only if the device model matches the one previously read. It is recommended to activate the Write All mode only when you need to replicate the same configuration on many other devices of the same model.
WRITE PROTECTION
Using the padlock button, you can set a block when writing parameters. A screen for entering a 4-character password will appear. Once this password has been written to the device, all subsequent parameter changes can only be made if the correct password is written to the Settings page of the app.
To remove the password lock, simply press the padlock button and leave the Password field blank.
WRITING ERROR
If, after writing the parameters, when you turn it back on, the device flashes 2 times per second continuously, it means that the writing was not successful. Therefore, you need to perform the following steps:
Turn off the device. Rewrite the parameters. Wait for the script to be successful or for no error messages to appear. Turn the device back on.
If it does not work, you can perform a factory reset by quickly turning the device off and on 6 times.
DALCNET S.r.l. 36077 Altavilla Vicentina (VI) Italy Via Lago di Garda, 22
Tel. +39 0444 1836680 www.dalcnet.com info@dalcnet.com
Rev. 08/04/2024 - Pag. 16/18
PRODUCT INFORMATION
LINE 5CV DMX
Device Manual
Made in Italy
Product Name: User-settable field for easy identification. By default, the product name is the same as the Model field.
Model: An immutable field. Identifies the device model.
Serial number: This field cannot be edited. Uniquely identifies the specimen.
Firmware version: field not editable. Identifies the firmware version currently loaded on the device.
IMPOSTAZIONI DI CONTROLLO
PWM frequency: allows you to set the frequency of PWM modulation of the output. NOTE: For applications in harsh thermal conditions, it is advisable to lower the PWM frequency to a minimum (307 Hz)
Dimming curve: For details, see the Dimming Curves section of the device manual
Control type: Selection of the control map (see next paragraph).
DALCNET S.r.l. 36077 Altavilla Vicentina (VI) Italy Via Lago di Garda, 22
Tel. +39 0444 1836680 www.dalcnet.com info@dalcnet.com
Rev. 08/04/2024 - Pag. 17/18
CONTROL TYPES
LINE 5CV DMX
Device Manual
Made in Italy
Within the "Control Type" configuration it is possible to select the various maps of the LINE-5CV-DMX, including:
MACRO DIMMER DIM TO WARM TUNABLE WHITE SMART HSI-RGB SMART HSI-RGBW RGB RGBW MRGB+S MRGBW+S DIMMER SMART HSI RGBW+TW
DMX ADDRESSING
For each type of control, the DMX address of the device can be defined within the range (0 ÷ 512).
POWER-ON SETTINGS
Depending on the type of control selected ("Smart HSI-RGB" in the example image) for each output channel it is possible to set the initial switch-on level: during powerup and in the absence of the DMX signal, the device will bring the outputs to the levels set in this section.
It is also possible to set the memorization of the last level available during the shutdown phase (e.g. in case of power failure), by selecting the "Last Level" option: in this case, during the switch-on and in the absence of the DMX signal, the device will bring the outputs to the levels stored during the shutdown phase.
For more information on output channel configurations and levels, refer to the "DMX512-RDM Channel Maps" section of this manual.
DALCNET S.r.l. 36077 Altavilla Vicentina (VI) Italy Via Lago di Garda, 22
Tel. +39 0444 1836680 www.dalcnet.com info@dalcnet.com
Rev. 08/04/2024 - Pag. 18/18