User Manual for Anolis models including: 1.6, UVinere Remote Series LED Light, UVinere Remote Series, LED Light, Light
File Info : application/pdf, 19 Pages, 3.56MB
DocumentDocumentQR code for user manual Version 1.6 UVinere Remote Table of contents 1. Safety instructions ......................................................................................................................................................3 2. Fixture exterior view...................................................................................................................................................5 3. Installation ..................................................................................................................................................................6 3.1 Mounting the fixture ............................................................................................................................................6 3.2 Connection to driver.............................................................................................................................................6 3.3 Wiring of the junction box....................................................................................................................................8 4. Software update .......................................................................................................................................................10 5. Technical specifications ............................................................................................................................................11 6. Cleaning and maintenance .......................................................................................................................................13 6.1 Disposing of the product ....................................................................................................................................13 7. ChangeLog ................................................................................................................................................................13 2 UVinere Remote FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING YOUR UVinere Remote ! Save it for future reference. This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure safe operation, it is absolutely necessary for the user to follow the safety instructions and warnings written in this manual. The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to the device. Unauthorized modification will void warranty. 1. Safety instructions THIS LUMINAIRE IS DESIGNED WITH UV LEDS AND MUST BE INSTALLED IN COMPLIANCE WITH COMPETENT TECHNICAL DIRECTIONS TO PREVENT THE USER'S EYE AND BARE SKIN FROM EXPOSURE TO HARMFUL UV RADIATION. CE LUMINAIRE EST CONCU POUR ETRE UTILISE AVEC DES LED UV ET DOIT ETRE INSTALLE EN STRICTE CONFORMITE AVEC LES INSTRUCTIONS AFIN D'EVITER QUE LES YEUX OU LA PEAU L'UTILISATEUR NE SOIENT EXPOSES AUX EFFETS NEFASTES DES RAYONS UV. CAUTION: Radiation exposure may cause blindness and cancer of skin! Distance from UV source 0.8m (2.6ft) 0.9m (3.0ft) 1m (3.3ft) 1.5m (4.9ft) 2m (6.6ft) 3m (9.8ft) 4m (13ft) 5m (16.4ft) 6m (19.7ft) 7m (23ft) 8m (26ft) 9m (29.5ft) 10m (32.8ft) Maximum exposure time (minutes) Non optical version UVinere 1 UVinere 2 UVinere 4 UVinere 1 21 26.6 32.9 74.0 131.5 295.9 526.0 821.8 1183.4 1610.8 2103.9 2662.7 3287.3 37.0 65.7 147.9 263.0 410.9 591.7 805.4 1051.9 1331.4 1643.7 18.5 32.9 74.0 131.5 205.5 295.9 402.7 526.0 665.7 821.8 24.5 55.0 97.9 152.9 220.2 299.7 391.4 495.4 611.6 24° UVinere 2 27.5 48.9 76.5 110.1 149.8 195.7 247.7 305.8 UVinere 4 24.5 38.2 55.0 74.9 97.9 123.9 152.9 3 UVinere Remote DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT! Always disconnect the fixture from power before cleaning, servicing or installing. This fixture falls under protection class III. The fixture was designed for outdoor use. This fixture must not be used for underwater installation. When choosing the installation spot, please make sure that the fixture is not exposed to extreme heat or dust. Do not install the unit near an open flame. Avoid using the unit in locations subject to possible impacts. The fixture body never must be covered with cloth or other materials when the fixture is under operation. Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened. The fixture becomes hot during operation. Allow the fixture to cool approximately 30 minutes prior to servicing or maintenance. Operate the fixture only after having familiarized yourself with its functions. Do not permit operation by persons not qualified to operate the fixture. Please consider that unauthorized modifications on the fixture are forbidden due to safety reasons! Please use the original packaging if the fixture is to be transported. If this device will be operated in any way different to the one described in this manual, the product may suffer damages and the warranty becomes void. Furthermore, any other operation may lead to dangers like short-circuit, burns, electric shock etc. Refer servicing to qualified service personnel. The product (covers and cables) must not be exposed to a high frequency electromagnetic field higher than 3V/m. Immunity of the equipment is designed according to the standard EN 55035 Electromagnetic compatibility of multimedia equipment - Immunity requirements Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia equipment Emission Requirements according to class B. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. The [Device] wireless operation is safe and complies to RF Exposure requirements. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed 4 UVinere Remote and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. Warning for fixtures with Harsh Environment Finish (HEF): Handle with care! Avoid any damage to the painted surface. Damaging the paint may result in corrosion and loss of warranty. 2. Fixture exterior view 1. Transparent glass cover 2. Gore tex valve 3. Cable gland M20 (IN) 4. Housing 5. Mounting brackets 6. Cable gland M20 (OUT) 7. Junction box 5 UVinere Remote 3. Installation 3.1 Mounting the fixture The UVinere Remote can be arranged in any orientation on a flat, non-flammable surface by means of two mounting brackets (5) which can be tilted by 30°. 3.2 Connection to driver The unit must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations. The UVinere Remote modules should be connected to the E-Box Remote or E-Box Remote basic as stated in the chapter "Technical specifications". Example of connection 6 UVinere Remote The table below states max. number of UVinere Remote modules connected to the E-box Remote/E-box Remote Basic. Cable length * 25 m 50 m 75 m 100 m Max. number of UVineres Remote UV connected to the E-box Remote/E-box Remote Basic UVinere Remote 1 UVinere Remote 2 UVinere Remote 4 20 10 5 16 8 4 13 6 3 10 5 2 * Cable length is a total cable length between E-box Remote (E-box Remote Basic) and last connected UVinere Remote. Example: Total cable length=L1+L2+L3+L3 Max. number of UVinere Remote modules connected to the one output of the E-box Remote/E-box Remote Basic is stated in the following table. Max. number of UVineres Remote connected to the one output of the E-box Remote/E-box Remote Basic UVinere Remote 1 UVinere Remote 2 UVinere Remote 4 16 8 4 Example: if you want to connect 10 UVineres Remote to the E-box Remote, you may connect 8 UVineres Remote 2 to the output 1 and 2 UVineres Remote UV 2 to the output 2 (at total cable length of 25 m). 7 UVinere Remote 3.3 Wiring of the junction box 1. Unscrew the four screws (9) on the cover (8) of the junction box (7), remove the cover (8) and the gasket (10). 2. Remove the end cap (11) from cable glands before passing cables throw cable glands M20 (3,6). The cable glands M20x1.5 can be used for cables of a diameter of 7-13mm. 3. Pass the power/data cables through the cable glands (3,6) and connect them to the connection blocks (12, 13). 4. After checking all connections, fill the junction box with synthetic resin. Make sure that the End cap is inserted in unused cable gland before filling it. At filling of the junction box proceed according instructions stated on the bag of the resin. The connection blocks have to be fully poured in the resin. 5. Place the gasket (10) on the junction box (7) and screw the cover (8) to the junction box (7). Check that all cable glands (and blind flange) and screws are firmly tightened. Wiring of connection blocks (12,13) in the junction box CE version Connector Vcc D+ Function LEDs + Data + Colour of wire Red Orange DData White 8 0V LEDs Black Ground Not connected US version Connector Function Colour of wire Vcc LEDs + Red UVinere Remote D+ Data + Orange DData White 0V LEDs Black Ground Yellow/Green NOTE: Each line of UVineres Remote connected to the LED output of the E-box Remote/E-box Remote Basic has to be terminated at the last fixture. EITHER connect a 120 Ohm resistor between terminals D+ and D- in the last fixture, OR terminate via RDM as described in the user manual for the E-box Remote. Ensure ONLY the last fixture in the line is terminated using ONE of the above methods! To keep declared IP rating of the fixture, every cable gland has to be covered with the end cap (11) if the cable gland is not used for cable passing. We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of the cable gland before inserting it into the body of the gland and an adequate layer of the paste LOCTITE 577 on the thread of the body of gland (if the cable gland was screwed out). 9 UVinere Remote 4. Software update Software update of UVinere Remote has to be done by means of the software ROBE Uploader running on PC. The ROBE Uploader is a software for automatized software update of ROBE fixtures. The ROBE Uploader switches Emineres Remote UV to the update mode automatically. Please see https://www.robe.cz/robe-uploader/ for more information about ROBE uploader and the E-box Remote user manual (E-box Remote Basic user manual). 10 UVinere Remote 5. Technical specifications Power supply · Input voltage: 48 V · Power consumption: UVinere Remote 1: 20W UVinere Remote 2: 40W UVinere Remote 4: 80W Optic · Light source: UVinere Remote 1: 8 x UV LEDs UVinere Remote 2: 16 x UV LEDs UVinere Remote 4: 32 x UV LEDs · UV LEDs Wave Length: 365nm · Beam Angle: optical version: 24° non-optical version: 92° · LEDs lifetime: 10.000 hrs Compatible drivers · E-box Remote, E-box Remote Basic Mounting method · Via two L-shape brackets with adjustment range 30° Housing · Aluminium extruded body · Tempered glass Cooling system · Convection Total heat dissipation · UVinere Remote 1: 51 BTU/h (calculated) · UVinere Remote 2: 102 BTU/h (calculated) · UVinere Remote 4: 205 BTU/h (calculated) Weight · UVinere Remote 1: 2 kg (4.41 lbs) · UVinere Remote 2: 3.1 kg (6.83 lbs) · UVinere Remote 4: 5.1 kg (11.24 lbs) 11 Dimensions (All dimensions in mm [inch]) UVinere Remote Protection factor · CE: IP 67 · US: Suitable for wet location Impact rating · CE: IK06 Operating ambient temperature range · -20°C /+40°C (-4°F /+104°F) Operating temperature · +67°C @ Ambient +40°C (+153°F @ Ambient +104°F) Connection · 5-cored cable Included items · 1 x UVinere Remote · 1 x User manual Optional accessories ·Cable for Eminere Remote (P/N 13053336) ·Black Glass Adaptor UVinere Remote 2 RAL9011 (P/N 10980752) ·Black Glass Adaptor UVinere Remote 4 RAL9011 (P/N 10980702) 12 6. Cleaning and maintenance UVinere Remote DANGER ! Disconnect from the mains before starting any maintenance or cleaning work Rinse off loose dirt with low pressure water spray. Wash the housing with a soft brush or sponge and a mild, nonabrasive washing detergent. Rinse it. Maintenance and service operations are only to be carried out by a qualified person. Should you need any spare parts, please use ROBE OEM parts. 6.1 Disposing of the product To preserve the environment please dispose or recycle this product at the end of its life according to the local regulations and codes. 7. ChangeLog This section summarizes changes in the user manual. Version of Date of issue Description of changes the manual 1.0 19/05/2022 QR code added 1.1 17/08/2022 Termination of Emineres line added, colors of wires changed 1.2 09/01/2023 Eminere Remote 1 added 1.3 18/01/2023 Device renamed to UVinere Remote 1.4 10/02/2023 DMX chart ver. 3.2 1.5 11/01/2024 Description of junction box connection 1.6 16/02/2024 Notice about Protection class III added to Safety instructins Specifications are subject to change without notice. February 16, 2024 Copyright © 2020-2024 Robe Lighting - All rights reserved Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o. Palackeho 416/20 CZ 75701 Valasske Mezirici 13 DMX protocol DMX protocol for: Eminere 1/2/3/4; Eminere Side 1/2/3/4; Eminere Inground 2/4; Eminere Remote 1/2/3/4; UVinere 2/4; UVinere Remote 1/2/4 Version: 3.3 (23 modes in total), software version 3.0 and higher Mode/Channels in all Mode 1: RGBW(A)-8bit, Mode 2: RGB 8-bit, Mode 3: full RGBW(A) 1 2 3 4 5 6 7 8-10 Mode 4: White-full control, Mode 5: Reduced RGBW(A) 4 3 12 3 6 8 15 Reserved Mode 6- Reduced RGBW(A)+white control Mode 7- full RGBW(A)+virtual colour wheel RGBW(A) / RGB modes Mode/channels DMX 1 2 3 4 5 6 7 Value Function - - - - - -1 Special functions 0 No function To activate following functions , stop in DMX value for at least 3 sec. 1-2 Save current DMX values to fixture as initial DMX values. 3-4 Show saved initial DMX values 5-6 Run factory demo sequences at switching fixture on (without DMX) 7-8 Insect friendly light On (RGBA version only) 9-10 Insect friendly light Off (RGBA version only) 11-255 Reserved 1 1 1 - 112 Red 0-255 Red LEDs saturation control (0-100%) - - 2 - - -3 Red Fine 0-255 Red LEDs saturation control fine 2 2 3 - 224 Green 0-255 Green LEDs saturation control (0-100%) - - 4 - - -5 Green Fine 0-255 Green LEDs saturation control fine 3 3 5 - 336 Blue 0-255 Blue LEDs saturation control (0-100%) - - 6 - - -7 Blue Fine 0-255 Blue LEDs saturation control fine 4 - 7 - 448 White (Amber) 0-255 White LEDs saturation control (0-100%) - - 8 - - -9 White (Amber) Fine 0-255 White LEDs saturation control fine - - 9 1 - 5 10 Green correction 0 Uncorrected white 1-127 Minus green --> uncorrected white 128 Uncorrected white (128=default) 129-255 Uncorrected white --> Plus green - - 10 2 - 6 11 Colour temperature correction (CTC) 0 No function 1-10 Tungsten dimming 2700 K 11-20 Tungsten dimming 3200 K 21-255 Colour temperature changing from 1800 K --> 6500 K Type of control step step step step step step proportional proportional proportional proportional proportional proportional proportional proportional step proportional step proportional step step step proportional Page 1 DMX protocol Mode/channels DMX 1 2 3 4 5 6 7 Value Function Type of control (21-1800K, 66-2700K, 91-3200K,141-4200K, 211-5600K, 255- - - - - - - 12 6500K) Virtual Colour Wheel 0 No function step 1-2 White 1800 K step 3-4 White 2700 K step 5-6 White 3200 K step 7-8 White 4200 K step 9-10 White 5600 K step 11-12 White 6500 K step 13 Blue (Blue=full, Red+Green+White/Amber=0) step 14-23 Red=0, Green->up,Blue =full, White/Amber=0 proportional 24 Cyan (Red=0, Green=full, Blue =full, White/Amber=0) step 25-34 Red=0, Green=full, Blue->down, White/Amber=0 proportional 35 Green (Red=0, Green=full, Blue =0, White/Amber=0) step 36-45 Red->up, Green=full, Blue=0, White/Amber=0 proportional 46 Yellow (Red=full, Green=full, Blue=0, White/Amber=0) step 47-56 Red=full, Green->down, Blue=0, White/Amber=0 proportional 57 Red(Red=full, Green=0, Blue=0, White/Amber=0) step 58-67 Red=full, Green=0, Blue->up, White/Amber=0 proportional 68 Magenta (Red=full, Green=0, Blue=full, White/Amber=0) step 69-78 Red -> down, Green=0, Blue=full, White/Amber=0 proportional 79 Blue (Red=0, Green=0, Blue=full, White/Amber=0) step Transition effects 80-87 Rainbow effect (with fade time) from slow-> fast proportional 88-95 Rainbow effect (without fade time) from slow-> fast proportional 96-103 Full dynamic white (1800K->6500K->1800K) (with fade time) from proportional slow-> fast 104-111 Full dynamic white (1800K->6500K->1800K) (without fade time) proportional from slow-> fast 112-119 Dynamic warm white (1800K-3000K-1800K) (with fade time) from slow-> fast 120-127 Dynamic warm white (1800K-3000K-1800K) (without fade time) from slow-> fast 128-135 Rainbow effect + full dynamic white (with fade time) from slow-> fast 136-143 Rainbow effect + full dynamic white (without fade time) from proportional proportional proportional proportional slow-> fast 144-151 Blue/Green effect (with fade time) from slow-> fast proportional 152-159 Blue/Green effect (without fade time) from slow-> fast proportional 160-167 Red/Blue effect (with fade time) from slow-> fast proportional 168-175 Red/Blue effect (without fade time) from slow-> fast proportional 176-183 Green/Red effect (with fade time) from slow-> fast proportional 184-191 Green/Red effect (without fade time) from slow-> fast proportional 192-199 Blue/4000K effect (with fade time) from slow-> fast proportional 200-207 Blue/4000K effect (without fade time) from slow-> fast proportional 208-215 Green/4000K effect (with fade time) from slow-> fast proportional 216-223 Green/4000K effect (without fade time) from slow-> fast proportional 224-231 Red/4000K effect (with fade time) from slow-> fast proportional 232-239 Red/4000K effect (without fade time) from slow-> fast proportional 240-255 Reserved Page 2 DMX protocol Mode/channels DMX 1 2 3 4 5 6 7 Value Function 13 Shutter/Strobe 0-31 Shutter closed 32-63 Shutter open 64-95 Strobe-effect from slow to fast 96-127 Shutter open 128-143 Opening pulse in sequences from slow to fast 144-159 Closing pulse in sequences from fast to slow 160-191 Shutter open 192-223 Random strobe-effect from slow to fast 224-255 Shutter open - - 11 3 5 7 14 Dimmer 0-255 Light intensity coarse (0-100%) - - 12 - 6 8 15 Dimmer Fine 0-255 Light intensity fine Copyright © 2022-2024 Robe Lighting s.r.o. - All rights reserved All Specifications subject to change without notice Type of control step step proportional step proportional proportional step proportional step proportional proportional Page 3 DMX protocol DMX protocol for: Eminere 1/2/3/4; Eminere Side 1/2/3/4; Eminere Inground 2/4; Eminere Remote 1/2/3/4; UVinere 2/4; UVinere Remote 1/2/4 Version: 3.3 (23 modes in total) Mode/Channels in all Mode 11: White selection, Mode 12: WW + CW 11 12 13 14-16 Mode 13: Only dimmer 3 4 2 Reserved Mode 13 is suitable for UVinere and UVinere Remote TW and PW modes Mode/channels 11 12 13 DMX Value Function 1 - - White colour selection 0 - 255 White from 2700 K - 6500 K - 1 - Warm White 0 - 255 Warm White LEDs saturation control (0-100%) - 2 - Cool White 0 - 255 Cool White LEDs saturation control (0-100%) 2 3 1 Dimmer 0 - 255 Light intensity coarse (0 - 100%) 3 4 2 Dimmer Fine 0 - 255 Light intensity fine Copyright © 2022-2024 Robe Lighting s.r.o. - All rights reserved All Specifications subject to change without notice Type of control proportional proportional proportional proportional proportional Page 4 DMX protocol DMX protocol for: Eminere 1/2/3/4; Eminere Side 1/2/3/4; Eminere Inground 2/4; Eminere Remote 1/2/3/4; Version: 3.3 (23 modes in total) Mode/Channels in all 17 18 19 20 16 12 8 8 Mode/channels 17 18 19 20 1 1 - - 2 2 - - 3 3 - - 4 - - - 5 4 - - 6 5 - - 7 6 - - 8 - - - 9 7 - - 10 8 - - 11 9 - - 12 - - - 13 10 - - 14 11 - - 15 12 - - 16 - - - - - 1 - - - 2 - - - 3 - Mode 17: RGBW(A) pixels, Mode 18: RGB pixels, Mode 19: TW pixels, 21-23 Mode 20: PW dimmer pixels Reserved Pixel modes DMX Value Function Type of control Red 1 -Eminere 1/2/3/4 0 - 255 Red LEDs saturation control (0-100%) proportional Green 1-Eminere 1/2/3/4 0 - 255 Green LEDs saturation control (0-100%) proportional Blue 1-Eminere 1/2/3/4 0 - 255 Blue LEDs saturation control (0-100%) proportional White (Amber) 1-Eminere 1/2/3/4 0 - 255 White LEDs saturation control (0-100%) proportional Red 2 -Eminere 2/3/4 0 - 255 Red LEDs saturation control (0-100%) proportional Green 2-Eminere 2/3/4 0 - 255 Green LEDs saturation control (0-100%) proportional Blue 2-Eminere 2/3/4 0 - 255 Red LEDs saturation control (0-100%) proportional White (Amber) 2-Eminere 2/3/4 0 - 255 White LEDs saturation control (0-100%) proportional Red 3-Eminere 3/4 0 - 255 Red LEDs saturation control (0-100%) proportional Green 3-Eminere 3/4 0 - 255 Green LEDs saturation control (0-100%) proportional Blue 3-Eminere 3/4 0 - 255 Blue LEDs saturation control (0-100%) proportional White (Amber) 3-Eminere 3/4 0 - 255 White LEDs saturation control (0-100%) proportional Red 4-Eminere 4 0 - 255 Red LEDs saturation control (0-100%) proportional Green 4-Eminere 4 0 - 255 Green LEDs saturation control (0-100%) proportional Blue 4-Eminere 4 0 - 255 Blue LEDs saturation control (0-100%) proportional White (Amber) 4 -Eminere 4 0 - 255 White LEDs saturation control (0-100%) proportional Warm White 1 -Eminere 1/2/3/4 Warm White LEDs saturation control (0-100%) proportional Cool White 1-Eminere 1/2/3/4 0 - 255 Cool White LEDs saturation control (0-100%) proportional Warm White 2-Eminere 2/3/4 Page 5 DMX protocol Mode/channels DMX 17 18 19 20 Value Function 0 - 255 Warm White LEDs saturation control (0-100%) - - 4 - Cool White 2-Eminere 2/3/4 0 - 255 Cool White LEDs saturation control (0-100%) - - 5 - Warm White 3-Eminere 3/4 0 - 255 Warm White LEDs saturation control (0-100%) - - 6 - Cool White 3-Eminere 3/4 0 - 255 Cool White LEDs saturation control (0-100%) - - 7 - Warm White 4 -Eminere 4 0 - 255 Warm White LEDs saturation control (0-100%) - - 8 - Cool White 4 -Eminere 4 0 - 255 Cool White LEDs saturation control (0-100%) - - - 1 Dimmer 1 0 - 255 Light intensity coarse (0 - 100%) - - - 2 Dimmer Fine 1 0 - 255 Light intensity fine - - - 3 Dimmer 2 0 - 255 Light intensity coarse (0 - 100%) - - - 4 Dimmer Fine 2 0 - 255 Light intensity fine - - - 5 Dimmer 3 0 - 255 Light intensity coarse (0 - 100%) - - - 6 Dimmer Fine 3 0 - 255 Light intensity fine - - - 7 Dimmer 4 0 - 255 Light intensity coarse (0 - 100%) - - - 8 Dimmer Fine 4 0 - 255 Light intensity fine Copyright © 2022-2024 Robe Lighting s.r.o. - All rights reserved All Specifications subject to change without notice Type of control proportional proportional proportional proportional proportional proportional proportional proportional proportional proportional proportional proportional proportional proportional Page 6