
Guide for APEX WAVES models including: PCIe-6612 Counter-Timer Module, PCIe-6612, Counter-Timer Module, Module
PCIe-6612 National Instruments Counter/Timer Device | Apex Waves
File Info : application/pdf, 4 Pages, 1.41MB
DocumentDocumentPCIe-6612 NOTE TO USERS NI 66xx Pinout Labels for the SCB-68A Counter/Timer Modules/Devices Using the 68-Pin Shielded Connector Block If you are using an NI 66xx (formerly referred to as TIO) counter/timer device or module with the SCB-68A, you can print and attach a connector-specific pinout label to the cover of the connector block for easy connection reference. This document provides the label for the following models: · NI 6601 · NI 6602 · NI 6608 · NI 6612 · NI 6614 Use the following label if you are connecting the SCB-68A to NI 6601, NI 6602, and NI 6608 models. Figure 1. NI 660x DIO/CTR 68 D GND 34 PFI 31/P0.31/CTR 2 SOURCE 67 PFI 30/P0.30/CTR 2 GATE 33 D GND 66 PFI 29/P0.29/CTR 2 AUX 32 PFI 28/P0.28/CTR 2 OUT 65 D GND 31 PFI 27/P0.27/CTR 3 SOURCE 64 PFI 26/P0.26/CTR 3 GATE 30 D GND 63 PFI 25/P0.25/CTR 3 AUX 29 PFI 24/P0.24/CTR 3 OUT 62 D GND 28 PFI 23/P0.23/CTR 4 SOURCE 61 PFI 22/P0.22/CTR 4 GATE 27 D GND 60 PFI 21/P0.21/CTR 4 AUX 26 PFI 20/P0.20/CTR 4 OUT DIO/CTR 59 D GND 25 PFI 19/P0.19/CTR 5 SOURCE 58 PFI 18/P0.18/CTR 5 GATE 24 D GND 57 PFI 17/P0.17/CTR 5 AUX 23 PFI 16/P0.16/CTR 5 OUT 56 R GND 22 PFI 15/P0.15/CTR 6 SOURCE 55 D GND 21 PFI 14/P0.14/CTR 6 GATE 54 PFI 13/P0.13/CTR 6 AUX 20 D GND 53 PFI 12/PO.12/CTR 6 OUT 19 R GND 52 PFI 11/P0.11/CTR 7 SOURCE 18 D GND DIO/CTR 51 PFI 10/PO.10/CTR 7 GATE 17 PFI 9/P0.9/CTR 7 AUX 50 D GND 16 PFI 8/P0.8/CTR 7 OUT 49 D GND 15 PFI 7/P0.7 48 PFI 6/P0.6 14 D GND 47 PFI 5/P0.5 13 PFI 4/P0.4 46 D GND 12 PFI 3/P0.3 45 PFI 2/P0.2 11 D GND 44 PFI 1/P0.1 10 PFI 0/P0.0 DIO/CTR 1 +5 V 35 R GND 2 PFI 39/CTR 0 SOURCE 36 D GND 3 PFI 38/CTR 0 GATE 37 RESERVED 4 RESERVED 38 RESERVED 5 PFI 36/CTR 0 OUT 39 D GND 6 PFI 33/CTR 1 AUX 40 PFI 37/CTR 0 AUX 7 PFI 35/CTR 1 SOURCE 41 D GND 8 PFI 34/CTR 1 GATE 42 D GND 9 PFI 32/CTR 1 OUT 43 R GND SCB-68A Quick Reference Label NI 660x Counter/Timer (TIO) Models R GND: These terminals are routed to RESERVED when using the product with a SH68-68-D1 shielded cable or routed to D GND when using the product with a R68-68 ribbon cable. Direct Feedthrough 1 S1 S2 2 123 2 | ni.com | NI 66xx Pinout Labels for the SCB-68A Note To Users Use the following label if you are connecting the SCB-68A to NI 6612 and NI 6614 models. Figure 2. NI 661x DIO/CTR 68 D GND 34 PFI 31/P0.31/CTR 2 SOURCE 67 PFI 30/P0.30/CTR 2 GATE 33 D GND 66 PFI 29/P0.29/CTR 2 AUX 32 PFI 28/P0.28/CTR 2 OUT 65 D GND 31 PFI 27/P0.27/CTR 3 SOURCE 64 PFI 26/P0.26/CTR 3 GATE 30 D GND 63 PFI 25/P0.25/CTR 3 AUX 29 PFI 24/P0.24/CTR 3 OUT 62 D GND 28 PFI 23/P0.23/CTR 4 SOURCE 61 PFI 22/P0.22/CTR 4 GATE 27 D GND 60 PFI 21/P0.21/CTR 4 AUX 26 PFI 20/P0.20/CTR 4 OUT DIO/CTR 59 D GND 25 PFI 19/P0.19/CTR 5 SOURCE 58 PFI 18/P0.18/CTR 5 GATE 24 D GND 57 PFI 17/P0.17/CTR 5 AUX 23 PFI 16/P0.16/CTR 5 OUT 56 R GND 22 PFI 15/P0.15/CTR 6 SOURCE 55 D GND 21 PFI 14/P0.14/CTR 6 GATE 54 PFI 13/P0.13/CTR 6 AUX 20 D GND 53 PFI 12/PO.12/CTR 6 OUT 19 R GND 52 PFI 11/P0.11/CTR 7 SOURCE 18 D GND DIO/CTR 51 PFI 10/PO.10/CTR 7 GATE 17 PFI 9/P0.9/CTR 7 AUX 50 D GND 16 PFI 8/P0.8/CTR 7 OUT 49 D GND 15 PFI 7/P0.7 48 PFI 6/P0.6 14 D GND 47 PFI 5/P0.5 13 PFI 4/P0.4 46 D GND 12 PFI 3/P0.3 45 PFI 2/P0.2 11 D GND 44 PFI 1/P0.1 10 PFI 0/P0.0 DIO/CTR 1 +5 V 35 R GND 2 PFI 39/P1.7/CTR 0 SOURCE 36 D GND 3 PFI 38/P1.6/CTR 0 GATE 37 RESERVED 4 RESERVED 38 RESERVED 5 PFI 36/P1.4/CTR 0 OUT 39 D GND 6 PFI 33/P1.1/CTR 1 AUX 40 PFI 37/P1.6/CTR 0 AUX 7 PFI 35/P1.3/CTR 1 SOURCE 41 D GND 8 PFI 34/P1.2/CTR 1 GATE 42 D GND 9 PFI 32/P1.0/CTR 1 OUT 43 R GND SCB-68A Quick Reference Label NI 661x Counter/Timer (TIO) Models R GND: These terminals are routed to RESERVED when using the product with a SH68-68-D1 shielded cable or routed to D GND when using the product with a R68-68 ribbon cable. Direct Feedthrough 1 S1 S2 2 123 Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for more information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patents Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. © 2017 National Instruments. All rights reserved. 376819A-01 Aug17
![]() |
NI 78xxR Pinout Labels for SCB-68 Connector Block Reference guide providing pinout labels for National Instruments NI 78xxR R Series modules and devices when used with the SCB-68 68-pin shielded connector block. Includes detailed pinout tables for RMIO, RAO, and RDIO connectors. |
![]() |
NI 78xxR Pinout Labels for SCB-68A Connector Block This document provides pinout labels for National Instruments 78xxR reconfigurable I/O modules and devices when used with the SCB-68A shielded connector block. |
![]() |
NI 78xxR Pinout Labels for SCB-68 Connector Block | National Instruments Provides detailed pinout labels and connector information for National Instruments NI 78xxR Reconfigurable I/O (RIO) devices when used with the SCB-68 Shielded Connector Block. Covers RMIO, RAO, and RDIO connector pin assignments. |
![]() |
NI-DAQ 6.6 for Mac OS Release Notes and Installation Guide Release notes and installation guide for National Instruments NI-DAQ 6.6 driver software for Mac OS, detailing supported hardware, platforms, installation steps, and configuration utilities. |
![]() |
National Instruments RF Signal Generators and Power Meters Overview A comprehensive overview of National Instruments' RF and microwave signal generators (NI PXI-5671, NI PXIe-5672, NI PXIe-5673, NI PXI-565x series) and RF power meter (NI USB-5680), detailing their key specifications, modulation capabilities, hardware architecture, software compatibility, and ordering information for various RF test and measurement applications. |
![]() |
NI 62xx/63xx Pinout Labels for SCB-68A Provides pinout labels for National Instruments (NI) 62xx and 63xx series multifunction I/O modules and devices when used with the SCB-68A shielded connector block, detailing connections for various connectors and configurations. |
![]() |
NI TB-2648/2649/2650/2651 Terminal Block Installation Instructions Installation guide for National Instruments TB-2648, TB-2649, TB-2650, and TB-2651 terminal blocks used with NI PXI/PXIe-2531 switch modules. Includes configuration details, physical installation steps, signal connection pinouts, and recommended accessories. |
![]() |
National Instruments Digital I/O Connectivity and Signal Conditioning Accessories A guide to National Instruments Digital I/O accessories, detailing cables, connector blocks, and signal conditioning hardware with compatibility information and product specifications. |