AmScope B120C-DK-E1
AmScope B120C-DK-E1 Binocular LED Darkfield Microscope User Manual
Model: B120C-DK-E1
Introducció
This manual provides instructions for the proper setup, operation, and maintenance of your AmScope B120C-DK-E1 Binocular LED Darkfield Microscope. This instrument is designed for educational, clinical, and laboratory applications, offering both brightfield and darkfield observation capabilities. Please read this manual thoroughly before using the microscope to ensure safe and effective operation.
Informació de seguretat
- Manegeu sempre el microscopi amb cura. Eviteu moviments o impactes bruscos.
- Assegureu-vos que el microscopi estigui col·locat sobre una superfície estable i anivellada per evitar que es bolqui.
- Disconnect the power cord before cleaning or performing any maintenance.
- Do not expose the microscope to direct sunlight, high temperatures, or high humidity.
- Feu servir només l'adaptador de corrent especificat.
- Keep the optical components clean. Avoid touching lenses with bare hands.
- Do not attempt to disassemble or repair the microscope yourself. Contact qualified service personnel.
Components i característiques
Familiarize yourself with the main components of your AmScope B120C-DK-E1 microscope:
Figura 1: Acabatview of the AmScope B120C-DK-E1 Binocular Compound Microscope, highlighting key features such as the 2-layer mechanical stage, 360-degree adjustable head, 40X-2500X magnification, coaxial coarse and fine focus, and LED sub-stage il·luminació.
Figura 2: The Siedentopf binocular head, featuring 360-degree rotation and a 30-degree inclination for comfortable viewing and posture adjustment.
Figura 3: Detallada view of the 2-layer mechanical stage and the coaxial coarse and fine focus knobs, designed for precise specimen movement and focusing.
Figura 4: Els subwoofers LEDtage lighting system, providing cool, energy-efficient, and daylight-balanced illumination for improved contrast and resolution.
Components clau:
- Siedentopf Binocular Head: Rotates 360 degrees with a 30-degree inclination for ergonomic viewing.
- Oculars: Includes 10X and 25X widefield eyepieces for various magnification levels.
- Lents objectius: Achromatic, color-coded objective lenses (e.g., 4X, 10X, 40X, 100X oil) mounted on a revolving nosepiece.
- Mecànica Stage: A 2-layer stage with low-position controls for precise X-Y movement of slides.
- Coaxial Focus Knobs: Separate coarse and fine focus adjustments for accurate focusing.
- LED Illuminator: Sub-stage LED light source with adjustable brightness.
- Condensador: Includes a brightfield condenser and a darkfield condenser for specialized observation.
- 1MP Digital Eyepiece Camera: For capturing images and videos, compatible with Windows, Mac, and Linux.
Configuració
- Desembalatge: Traieu amb cura tots els components de l'embalatge. Conserveu l'embalatge per a futurs transports o emmagatzematge.
- Col·locació: Col·loqueu el microscopi sobre una superfície estable i sense vibracions, allunyada de la llum solar directa i de fonts de calor.
- Instal·lació del capçal: Loosen the head retaining screw on the top of the microscope body. Gently insert the binocular head into the opening, ensuring it is fully seated. Tighten the retaining screw.
- Instal·lació de l'ocular: Remove the protective caps from the eyepiece tubes. Insert the desired eyepieces (10X or 25X) into the tubes.
- Objective Lens Installation: Rotate the revolving nosepiece to ensure there is no objective lens directly above the stage. Screw the objective lenses into the nosepiece in increasing order of magnification (e.g., 4X, 10X, 40X, 100X).
- Connexió d'alimentació: Connect the power cord to the microscope's power input and then to a suitable electrical outlet.
- Digital Eyepiece Camera Installation: If using the digital eyepiece, remove one of the standard eyepieces and insert the 1MP digital eyepiece camera into the eyepiece tube. Connect the camera to your computer via USB.
Instruccions de funcionament
1. Brightfield Observation
Figura 5: Examples of magnification levels (10X, 100X, 400X, 1000X) achievable with the AmScope B120C-DK-E1, utilizing various objective lenses and eyepieces, including the additional 25X eyepieces for up to 2500X magnification.
- Encès: Turn on the main power switch. Adjust the LED illuminator brightness using the dimmer control.
- Stage Ajust: Baixar el s mecànictage using the coarse focus knob to create enough space to place a slide.
- Slide Placement: Place a prepared specimen slide onto the mechanical stage, assegurant-ho amb la stage clips. Use the X-Y stage controls to position the specimen over the light aperture.
- Magnification Selection: Rotate the revolving nosepiece to select the lowest power objective lens (e.g., 4X). Ensure it clicks into place.
- Enfocament:
- Mentre mireu pels oculars, aixequeu lentament la stage utilitzant el botó d'enfocament aproximat fins que la mostra quedi força enfocada.
- Use the fine focus knob to achieve sharp focus.
- Adjust the interpupillary distance (distance between eyepieces) and diopter adjustment on the eyepiece for comfortable viewing and to correct for differences in vision between your eyes.
- Incrementasing Magnification: Once focused at low power, rotate the nosepiece to a higher power objective (e.g., 10X, 40X). The microscope is parfocal, meaning only minor adjustments with the fine focus knob should be needed.
- Ús de l'objectiu d'immersió en oli 100X:
- After focusing with the 40X objective, rotate the nosepiece halfway between the 40X and 100X objectives.
- Place a small drop of immersion oil directly onto the center of the specimen slide.
- Rotate the 100X objective into the oil drop. The objective lens should make contact with the oil.
- Use only the fine focus knob to bring the image into sharp focus. Do not use the coarse focus knob with the 100X objective.
- After use, clean the 100X objective lens and the slide immediately with lens cleaning solution and lens paper.
- Condenser Adjustment: Adjust the iris diaphragm on the condenser to control the amount of light and contrast. For higher magnifications, open the diaphragm more. For lower magnifications, close it slightly. The condenser can also be centered for optimal illumination.
2. Darkfield Observation
The AmScope B120C-DK-E1 includes a darkfield condenser for observing unstained, live specimens.
- Condenser Exchange: Remove the brightfield condenser from its mount beneath the stage. Carefully insert the darkfield condenser into the mount. Ensure it is seated correctly.
- Preparació de la mostra: Darkfield observation works best with thin, unstained specimens.
- Il·luminació: Turn on the LED illuminator and set it to a high brightness level.
- Enfocament: Use a low power objective (e.g., 10X or 20X, if available) first. Focus on the specimen as you would in brightfield. The specimen will appear brightly lit against a dark background.
- Centering the Darkfield Condenser: Some darkfield condensers require centering. If your condenser has centering screws, adjust them until the darkfield effect is uniform across the field of view.
- Higher Magnification: For higher magnifications, you may need to use a specialized darkfield objective or ensure your standard objectives are compatible. Always ensure sufficient immersion oil is used with 100X darkfield objectives.
3. Digital Eyepiece Camera Operation
The included 1MP digital eyepiece camera allows for image capture and live viewtreballant en un ordinador.
Figura 6: The AmScope B120C-DK-E1 microscope connected to a laptop, demonstrating live digital viewing and image capture capabilities via the 1MP digital eyepiece camera.
- Instal·lació de programari: Install the professional microscopy software provided (or download the latest version from the AmScope website) onto your Windows, Mac, or Linux computer.
- Connect Camera: Insert the digital eyepiece camera into one of the microscope's eyepiece tubes and connect it to your computer via the USB cable.
- Programari de llançament: Open the installed microscopy software. The software should detect the camera automatically.
- Viu View: The software will display a live feed from the microscope. Adjust microscope focus and illumination for the best image.
- Image/Video Capture: Use the software's functions to capture still images or record videos of your observations. The software also provides tools for image processing and measurement.
Manteniment
- Neteja de lents: Use a soft brush to remove dust from lens surfaces. For smudges or oil, use a small amount of lens cleaning solution on lens paper. Wipe gently in a circular motion. Never use abrasive cloths or harsh chemicals.
- Neteja del cos: Netegeu el cos del microscopi amb un drap suau iamp drap. Eviteu que la humitat entri en els components elèctrics.
- Emmagatzematge: Quan no l'utilitzeu, cobriu el microscopi amb una funda antipols per protegir-lo de la pols i les restes. Guardeu-lo en un lloc fresc i sec.
- Oli d'immersió: Always clean immersion oil from the 100X objective and slides immediately after use. Dried oil can be difficult to remove and can damage the lens.
Resolució de problemes
| Problema | Causa possible | Solució |
|---|---|---|
| Sense il·luminació | Power cord disconnected, power switch off, dimmer set to minimum, LED bulb failure. | Check power connections, turn on switch, adjust dimmer, contact support if LED is faulty. |
| Imatge poc clara/borrosa | Incorrect focus, objective lens dirty, eyepiece dirty, slide upside down, condenser not adjusted. | Adjust coarse/fine focus, clean lenses, ensure slide is correct side up, adjust condenser/diaphragm. |
| Taques fosques al camp de view | Pols a l'ocular, l'objectiu o la diapositiva. | Clean eyepieces, objectives, and slides. Rotate eyepiece to determine if dust is on eyepiece. |
| No darkfield effect | Incorrect condenser, condenser not centered, illumination too low. | Ensure darkfield condenser is installed, center the condenser, increase illumination brightness. |
| Digital camera not detected | USB cable disconnected, software not installed, driver issue. | Check USB connection, install software/drivers, restart computer. |
Especificacions
| Model | B120C-DK-E1 |
| Cap | Binocular Siedentopf, giratori de 360°, inclinat a 30° |
| Oculars | WF10X, WF25X |
| Lents Objectives | Achromatic 4X, 10X, 40X (Spring), 100X (Spring, Oil) |
| Ampliació total | 40X-2500X |
| Nasal | Revolving Quadruple |
| Stage | S mecànica de 2 capestage with X-Y Scale |
| Centrant-se | Coaxial Coarse & Fine Adjustment |
| Il·luminació | LED Transmitted Light with Dimmer |
| Condensador | Abbe NA1.25 (Brightfield), Darkfield Condenser |
| Càmera digital | 1MP USB Digital Eyepiece Camera |
| Font d'alimentació | Elèctric amb cable |
| Material | Metall |
| Color | Blanc |
Garantia i Suport
The AmScope B120C-DK-E1 microscope comes with a 5 any de garantia del fabricant. For warranty claims, technical support, or service inquiries, please contact AmScope customer service directly.
For additional resources, software downloads, and frequently asked questions, please visit the official AmScope weblloc: