AmScope B120C

AmScope 40X-2500X LED Compound Binocular Laboratory Microscope

Model: B120C

Marca: AmScope

Introducció

The AmScope B120C binocular compound microscope is engineered for educational, clinical, and laboratory applications. It is an ideal instrument for students and professionals in medical and biological fields. This microscope features a professional Siedentopf binocular head, a double-layer mechanical stage, coaxial coarse and fine focusing, and LED illumination. It offers six magnification settings ranging from 40x to 2500x, making it suitable for detailed biological, pharmaceutical, and bacteriological research.

This manual provides essential information for the proper setup, operation, maintenance, and troubleshooting of your AmScope B120C microscope to ensure optimal performance and longevity.

Muntatge i muntatge

Upon unboxing, carefully remove all components from the packaging. Ensure all parts are present and undamaged before proceeding with assembly.

AmScope B120C Microscope fully assembled with sample view

Figure 1: Fully assembled AmScope B120C microscope with an example of a blood cell sample under observation.

Passos de configuració inicials:

  1. Desembalatge: Gently remove the microscope body, binocular head, eyepieces, objectives, and power cord from their protective packaging.
  2. Attaching the Binocular Head: Loosen the head locking screw on the top of the microscope body. Carefully insert the binocular head into the top port, ensuring it is fully seated. Tighten the locking screw to secure the head.
  3. Inserció d'oculars: Insert the WF10X and WF25X widefield eyepieces into the eyepiece tubes of the binocular head.
  4. Installing Objectives: Rotate the revolving nosepiece to expose the empty objective ports. Screw in the 4x, 10x, 40x (S), and 100x (S, oil) achromatic objectives into the nosepiece in ascending order of magnification.
  5. Connexió d'alimentació: Connect the power cord to the microscope's power input and then to a 240 Volt AC power outlet. Ensure the power switch is in the OFF position before connecting.
  6. Ajust de la distància interpupil·lar: While looking through the eyepieces, adjust the distance between the eyepiece tubes by moving them closer or further apart until a single, clear circular field of view s'observa.
  7. Ajust de diòptries: If one eye is dominant or has different vision, use the diopter adjustment ring on one of the eyepiece tubes to fine-tune focus for that eye after focusing with the other eye.

Instruccions de funcionament

Binocular Head Rotation:

The Siedentopf binocular head can be rotated 360 degrees and is inclined at 30 degrees for comfortable viewing, reducing neck strain during prolonged use.

Binocular head rotation and inclination diagram

Figure 2: The binocular head offers 360-degree rotation and a 30-degree inclination for ergonomic viewing.

Configuració d'ampliació:

The microscope provides six widefield magnification settings by combining the WF10X and WF25X eyepieces with the 4x, 10x, 40x, and 100x objectives:

  • 40x (10x eyepiece x 4x objective)
  • 100x (10x eyepiece x 10x objective)
  • 250x (25x eyepiece x 10x objective)
  • 400x (10x eyepiece x 40x objective)
  • 1000x (10x eyepiece x 100x objective)
  • 2500x (25x eyepiece x 100x objective)
Microscope objectives and eyepieces with magnification examples

Figure 3: Illustration of various magnification levels achievable with the included objectives and eyepieces.

Mecànica Stage and Focusing:

La mecànica de doble capatage allows for smooth and precise movement of specimen slides. Use the coaxial coarse and fine focus knobs located on both sides of the microscope for accurate focusing.

  • Botó d'enfocament aproximat: Used for large adjustments to bring the specimen into approximate focus.
  • Botó d'enfocament fi: Used for small, precise adjustments to achieve sharp focus.
  • StagBloqueig electrònic: A stage locking device protects objectives and slides from accidental contact.
Mecànica stage and focus knobs diagram

Figura 4: La mecànicatage provides precise slide positioning, controlled by separate coarse and fine focus knobs.

Sistema d'il·luminació LED:

The microscope features powerful LED transmitted illumination with variable intensity. The light source is daylight balanced to produce natural colors for imaging, improving contrast and resolution.

  • Condensador Abbe: The NA1.25 Abbe condenser with an iris diaphragm and filters allows for precise control over the illumination aperture and contrast.
  • Rack and Pinion Adjustment: The condenser can be adjusted vertically using a rack and pinion mechanism.
LED illumination system diagram

Figure 5: The LED sub-stage lighting provides cool, energy-efficient illumination for clear specimen viewing.

Person using AmScope B120C microscope

Figure 6: A user observing a specimen through the AmScope B120C microscope.

Microscòpic view of pink biological tissue

Figura 7: Example of a biological tissue sample as seen through the microscope.

Microscòpic view of plant cells

Figura 8: Example of plant cells observed under the microscope.

Manteniment i cura

Un manteniment adequat garanteix la longevitat i el rendiment òptim del vostre microscopi.

  • Òptiques de neteja: Use only specialized lens cleaning paper and lens cleaning solution for objectives and eyepieces. Never touch optical surfaces with bare fingers. Dust can be removed with a soft brush or air blower.
  • Neteja del cos: Netegeu el cos del microscopi amb un drap suau iamp tela. Eviteu utilitzar productes químics aggressivs o netejadors abrasius.
  • Emmagatzematge: When not in use, cover the microscope with a dust cover to protect it from dust and debris. Store in a dry, cool place away from direct sunlight and extreme temperatures.
  • Bulb Recycling: For information on recycling the LED bulb, please refer to local regulations and guidelines for electronic waste.
  • Broken Bulb Handling: In the event of a broken bulb, exercise caution. Do not touch broken glass directly. Refer to local guidelines for safe cleanup and disposal of broken lamps.

Resolució de problemes

Aquesta secció tracta problemes comuns que podeu trobar amb el vostre microscopi.

ProblemaCausa possibleSolució
Sense il·luminacióPower cord disconnected; power switch off; intensity knob set to minimum.Check power connection; turn on power switch; increase intensity.
Imatge borrosa o desenfocadaIncorrect focus adjustment; objective not fully engaged; slide upside down.Adjust coarse and fine focus; rotate nosepiece until objective clicks into place; ensure slide cover slip is facing up.
Eyepiece does not stay in positionEyepiece not fully inserted or locking mechanism loose.Ensure eyepiece is fully seated in the tube. If a locking screw is present, tighten it gently.
UK plug provided without adapterIncorrect regional power plug.An adapter for your region (e.g., Schuko for EU) should be included. If not, contact customer support.

Especificacions

CaracterísticaDetall
ModelB120C
MarcaAmScope
Tipus de microscopiCompound Binocular
OcularsWF10X, WF25X Widefield
Objectius4x, 10x, 40x (S), 100x (S, oil) Achromatic DIN
Interval d'ampliació40x - 2500x
CapBinocular Siedentopf, inclinat 30 graus, giratori 360 graus
Distància interpupilarAjustable
Ajust de diòptriesOn left eyepiece tube
NasalRevolving, Quadruple
StageS mecànica de doble capatage, Stain-resistant
Centrant-seCoaxial Coarse and Fine Focus, with tension control and stagi parada
Il·luminacióLED Transmitted, Variable Intensity
CondensadorNA1.25 Abbe Condenser with Iris Diaphragm and Filters, Rack and Pinion Adjustment
Font d'alimentació240 Volt AC, Battery Power (Type: Battery Power Supply)
MaterialMetall
Dimensions45.6 x 31.6 x 24 cm
Pes4.46 kg

Garantia i Suport

For warranty information, technical support, or any inquiries regarding your AmScope B120C microscope, please contact the seller, AmScope Global, directly through the platform where the purchase was made. Ensure you have your purchase details and model number (B120C) ready for faster assistance.

You can typically find seller contact information on your order details page or by visiting the AmScope brand store on Amazon.

Visit the AmScope Store on Amazon

© 2024 AmScope. Tots els drets reservats.

Aquest manual només té finalitats informatives. Les especificacions estan subjectes a canvis sense previ avís.

Ask a question about this manual