1. Introducció
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the MITSUBISHI FR-D740-036-NA FR-D700 Series Inverter Drive. This device is a three-phase inverter designed for motor speed control applications, rated at 2 HP, 3.6 AMP, and 400 V. Please read this manual thoroughly before attempting to install or operate the unit.
2. Informació de seguretat
PERILL: Improper handling can lead to serious injury or death. Ensure all power is disconnected before installation or maintenance. Only qualified personnel should perform electrical work.
PRECAUCIÓ: Failure to follow instructions may result in minor injury or equipment damage. Observe all warnings and instructions provided in this manual and on the product labels.
- Do not operate the inverter with wet hands.
- Do not touch internal components immediately after power-off, as residual voltage pot estar present.
- Assegureu-vos de posar a terra correctament l'inversor.
- Install the inverter in an environment free from excessive dust, moisture, corrosive gases, or direct sunlight.
3. Producte acabatview
The MITSUBISHI FR-D740-036-NA is a compact and versatile inverter drive from the FR-D700 series, designed for various industrial applications requiring precise motor speed control. It features an integrated control panel for easy operation and monitoring.

Figura 3.1: Davant view of the MITSUBISHI FR-D740-036-NA Inverter Drive. The image displays the dark gray unit with the MITSUBISHI logo at the top left, an LED display, and a control panel featuring a rotary dial, 'RUN', 'STOP/RESET', 'MODE', 'SET', and 'PU/EXT' buttons. Ventilation grilles are visible on the right side. The unit is labeled 'D700' and '3φ 400V'.
3.1. Components clau
- Tauler de control: Features an LED display, rotary dial, and push buttons for parameter setting and operation.
- Terminals de potència: Per connectar l'entrada d'alimentació i la sortida del motor.
- Terminals de control: For external control signals.
- Heat Sink/Ventilation: Dissenyat per a una dissipació eficient de la calor.
4. Configuració i instal·lació
4.1. Muntatge
Mount the inverter vertically on a flat, non-flammable surface. Ensure adequate clearance around the unit for proper ventilation (at least 50mm above and below, and 10mm on sides).
4.2. Cablatge
- Power Input (R/L1, S/L2, T/L3): Connect the three-phase 400V AC power supply.
- Sortida del motor (U, V, W): Connecteu-ho als terminals del motor.
- Grounding (E/PE): Ensure the inverter is properly grounded to prevent electrical shock and noise.
- Control Circuit Wiring: Connect external control signals (e.g., start/stop, speed reference) to the control terminals as per your application requirements. Refer to the detailed wiring diagrams in the full technical manual for specific terminal assignments.
Nota: Use appropriate wire gauges and ensure all connections are secure to prevent loose contacts and potential hazards.
5. Instruccions de funcionament
5.1. Engegada inicial
After completing wiring, apply power to the inverter. The LED display will illuminate, typically showing the current frequency or a status code.
5.2. Funcionament bàsic a través del tauler de control
- Botó EXECUTAR: Press to start the motor.
- Botó STOP/RESET: Press to stop the motor or reset an alarm.
- Botó MODE: Cycles through display modes (e.g., output frequency, output current, output voltagi).
- Botó SET: Used to enter parameter setting mode or confirm a setting.
- Marcador rotatiu: Adjusts frequency reference or parameter values.
- PU/EXT Button: Toggles between PU (Panel Unit) operation and EXT (External) control.
5.3. Configuració de paràmetres
To adjust operating parameters (e.g., maximum frequency, acceleration/deceleration time):
- Premeu el botó MODE button until the desired parameter group is displayed.
- Premeu el botó SET button to enter parameter setting mode.
- Utilitza el Dial rotatiu to select the specific parameter number.
- Premeu SET de nou a view el valor actual.
- Utilitza el Dial rotatiu per canviar el valor.
- Premeu SET per guardar el nou valor.
- Premeu MODE per sortir de la configuració dels paràmetres.
Refer to the MITSUBISHI FR-D700 Series technical manual for a complete list of parameters and their functions.
6. Manteniment
Regular maintenance ensures optimal performance and extends the lifespan of the inverter drive. Always disconnect power before performing any maintenance.
6.1. Controls diaris
- Check for abnormal noises or vibrations.
- Monitor the display for error codes.
- Ensure cooling fan is operating correctly and not obstructed.
6.2. Periodic Checks (Monthly/Quarterly)
- Clean dust and debris from the heat sink and ventilation openings.
- Inspect wiring for signs of damage, loose connections, or discoloration.
- Check terminal screws for tightness.
- Verify environmental conditions (temperature, humidity).
6.3. Substitució de components
Components such as cooling fans and capacitors have a finite lifespan. Refer to the technical manual for recommended replacement intervals. Replacement should only be performed by qualified service personnel.
7. Solució De Problemes
This section outlines common issues and their potential solutions. For detailed error codes and advanced troubleshooting, consult the comprehensive MITSUBISHI FR-D700 Series technical manual.
| Codi de símptoma/error | Causa possible | Acció Correctiva |
|---|---|---|
| Sense pantalla/Sense alimentació | No input power; Blown fuse; Faulty wiring. | Comprovar l'alimentació; Inspeccionar els fusibles; Verificar les connexions del cablejat. |
| El motor no funciona | Stop command active; Incorrect frequency setting; Motor wiring error. | Check control signals; Adjust frequency; Verify motor connections (U, V, W). |
| Overcurrent alarm (E.OC1, E.OC2, E.OC3) | Sudden load change; Short circuit in motor/wiring; Inverter capacity too small. | Check load conditions; Inspect motor/wiring; Ensure inverter matches motor requirements. |
| Overvoltage alarm (E.OV1, E.OV2) | Regenerative energy from motor; High input voltage. | Increase deceleration time; Install braking resistor if necessary; Check input voltage. |
8. Especificacions
The following are key specifications for the MITSUBISHI FR-D740-036-NA Inverter Drive:
- Model: FR-D740-036-NA
- Sèrie: Sèrie FR-D700
- Rated Motor Output: 2 CV (1.5 kW)
- Corrent de sortida nominal: 3.6 AMP
- Entrada Voltage: Three-Phase, 400 V AC (380-480V)
- Vol. De sortidatage: Three-Phase, 400 V AC (proportional to input voltage)
- Interval de freqüència de sortida: 0.2 a 400 Hz
- Mètode de control: Soft-PWM control, V/F control, General-purpose magnetic flux vector control
- Dimensions (aprox.): 9 x 7 x 9 polzades
- Pes (aprox.): 4 lliures
- Condicions ambientals:
- Operating Temperature: -10°C to +50°C (14°F to 122°F)
- Storage Temperature: -20°C to +65°C ((-4°F to 149°F)
- Humidity: 90% RH or less (non-condensing)
- Normes aplicables: US/CA/MX Specification
9. Garantia i Suport
9.1. Informació de la garantia
MITSUBISHI Electric products are typically covered by a standard manufacturer's warranty against defects in materials and workmanship. The specific terms and duration of the warranty may vary by region and product. Please refer to the warranty documentation provided with your purchase or contact your local MITSUBISHI Electric representative for details.
9.2. Suport tècnic
For technical assistance, troubleshooting beyond this manual, or service inquiries, please contact your authorized MITSUBISHI Electric distributor or visit the official MITSUBISHI Electric weblloc web per a recursos de suport i informació de contacte.
Recursos en línia: www.mitsubishielectric.com