  • Arrowg+ard Blue® Three-Lumen Catheter: 12 Fr. (4.1 mm OD) x 16 cm
  • Spring-Wire Guide, Marked: .035″ (0.89 mm) dia. x 23-5/8″ (60 cm) (Straight Soft Tip on One End – “J” Tip on Other) with Arrow Advancer
  • Catèter: 18 Ga. x 2-1/2″ (6.35 cm) Radiopac més de 20 Ga. RW Agulla introductora
  • Agulla d'injecció: 25 Ga. x 1 "(2.54 cm)
  • Agulla de farciment contundent: 18 Ga. X 1-1 / 2 ″ (3.81 cm)
  • Pressure Transduction Probe
  • Introducer Needle: 18 Ga. x 2-1/2″ (6.35 cm) XTW and 5 mL Arrow® Raulerson Spring-Wire Introduction Syringe
  • Injection Needle: 22 Ga. x 1-1/2″ (3.81 cm) and 5 mL Luer-Slip Syringe
  • Xeringa: 3 mL Luer-Lock
  • Tissue Dilator: 12 Fr. (4.0 mm) x 14 cm
  • 5 ml Solució de lidocaïna HCl a l'1% i preparació d'alcohol
  • 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®1 One-Step Solution with Hi-Lite Orange™ Tint
  • SharpsAway® II Locking Disposal Cup
  • SharpsAway® Disposal Cup
  • Drap: 41 "x 55" amb fenestració de 4".
  • Porta-agulles
  • Bisturí de seguretat: #11
  • Coixinet de gasa: 2 "x 2" (5 cm x 5 cm)
  • Coixinet de gasa: 4 "x 4" (10 cm x 10 cm)
  • Suture: 3-0 Silk with Curved Needle

1A registered trademark of CareFusion or one of its subsidiaries.

Només Rx
Advertència: Read all package insert warnings, precautions, and instructions prior to use. Failure to do so may result in severe patient injury or death. California Prop. 65
⚠ ADVERTÈNCIA: Càncer i danys reproductius.
www.P65Warnings.ca.gov
Not made with natural rubber latex. Store between 20 – 25°C (68 – 77°F). Sterilized using ethylene oxide unless otherwise indicated in the contents list. Fluid path components are non-pyrogenic.
contraindicacions: The Arrowg+ard Blue antimicrobial catheter is contraindicated for patients with known hypersensitivity to chlorhexidine, silver sulfadiazine and/or sulfa drugs. ARROW AK-22123-CDC Lumen CVC for High Volume Infusions-FIG21

Priming volumes are approximate and are done without accessories. † Flow rate values are approximate and are determined using deionized water at 100 cm head height. Arrow International LLC Subsidiary of Teleflex Incorporated 3015 Carrington Mill Blvd. Morrisville, NC 27560 USA

Documents/Recursos

ARROW AK-22123-CDC Lumen CVC for High Volume Infusions [pdf] Manual d'usuari
AK-22123-CDC Lumen CVC for High Volume Infusions, Lumen CVC for High Volume Infusions, High Volume Infusions, Volume Infusions

referències

Deixa un comentari

La seva adreça de correu electrònic no es publicarà.