telemetry & changeover

TLC 300/T2
TLC2000/T….
RDMODSER-FM
RDMODGSM-FM

Broadcast TLC2000-T Telemetry and Changeover A0 TLC2000 front view

Features
  • PRIMARY APPLICATION: RVR telemetry systems allow for an immediate intervention in case of fault, thanks to the radio station remote control. Equipment great flexibility makes it possible to control a high number of devices or to modify the station layout. This operation does not involve any radical changes of the control system, it is simply a matter of adding expansion boards that will increase the number of operating parameters the system can manage.
  • TELEMETRY FEATURES: all RVR telemetry devices control and program the alarms, send/receive text messages (SMS), connect to external/internal GSM and PSTN modems, and use the telecon control software designed by RVR.
    The various functions, technical data and the available product versions are detailed in the following sections of this catalogue about functional specifications, technical specifications and product versions.
  • HARDWARE FEATURES: all RVR telemetry systems are housed in lightweight and rugged stainless steel rack cases having the dimension of 1 HE or 2 HE.
  • USER-FRIENDLY FEATURES: the front panel features many leds that indicate instant system status to the operator.
    In model TLC2000 the user-friendly HMI with graphic display ensures prompt reading and setting up of all operating parameters. It is possible to control and vary any system setting through a simple knob (encoder).
  • EASE OF MAINTENANCE: all RVR telemetry systems are assembled using modules and boards with connectors so that it is easy to remove, replace and add modules and boards.
  • RELIABILITY/CONTINUITY: TLC 2000 and TLC300 telemetry systems feature 24 V power connector that could be used in case of mains power failure.
    RDMODSER or GSM products are battery-powered.
  • NTERFACE CONTROL: the rear panel features all connectors that could be used to connect the equipment to the various station components. (see technical specifications section). Although our telemetry systems are designed to communicate in the best way possible with all RVR equipment, they can also interface with the equipment of other manufacturers, as far as their main operating parameters are output via analogue signals with value between 0 and +5V.
    The Telecon software used for remotely controlling the equipment is one of the most comprehensive and powerful systems on the market and, yet, it features a user-friendly HMI.
    Telecon developed by RVR Elettronica is fully compatible with any WINDOWS™ operating system.
  • REGULATORY COMPLIANCE: all RVR telemetry systems comply with EC, FCC and CCIR standards.
Telemetry unit

Broadcast TLC2000-T Telemetry and Changeover A1

  1. TLC300/T2 front view
  2. RDMODGSM-FM front view

TCP INT-PTX-16
TCP INT-DDS
TCP INT-TEX
TEL INK-C1
TEL INK-SNMP2

 

Broadcast TLC2000-T Telemetry and Changeover A2 Broadcast TLC2000-T Telemetry and Changeover A3
TCP-IP Interface                               TELINK-C1 Interface

Features

TCP-IP
Allows the telemetry of RVR equipments remotely, through internet network, or a local LAN network in standard TCP/IP protocol.
Allows the reading of equipment values linked to the interface through a common PC’s browser (HTTP).
Can receive start and stop commands and send alarms by e-mail (SMTP).
Built-in a powerful 16bit DSP Bit of 52MIPS to control all advanced features.
The TCP/IP interface opens the telemetry of RVR equipments to the Internet world.
Designed in order to connect to an ADSL router or to a LAN network with server DHCP internet function any RVR equipment predisposed for the telemetry with TELECON via RS232.
It uses a powerful 16bit DSP Bit of 52MIPS and it is equipped with standard power supply input.
It realizes the telemetry remotely through a “tunnel” in Internet network, or a local LAN network in standard TCP/IP protocol.
Every equipment is identified from a owner static address (for example 192.168.0.244) or through a DNS server can be identified from a name (for example RADIO RVR ELETTRONICA).
The address is connected as DHCP client.
The security is guaranteed in the access through LOGIN with User ID and Password; moreover it is guaranteed through 2 levels password (User and Administrator).
E-mail messages: the alarms come signal to you by e-mail. The start and stop commands are given from outside through e-mail (SMTP).
FTP server: data transfer process.
It is possible to give enabling or disabling commands to the equipment, read values of power etc.

TELINK
The TELINK is an interface endowed with a microcomputer with risc microprocessor and an operating system specialized resident RTOS in the simultaneous management of data that transit throught 4 serial ports.
The TELINK opens the channel of telemetry standard RVR, available on connector DB9 and normally connected to the Telecon32 or to the modem, to systems of telemetry of station of high-level what ANTLAN, BURK, SNMP.
Besides it has a Web resident Server that allows to be connected online ethernet and explored by a normal browser type explorer or similar (function HTML). Besides it supports the messages e-mail to signal errors of system. The protocols TCP/IP, Telnet, http, SNMP, XML/RSS, HTTPS/SSL/SSH is managed by a DSP to 120Mhz inside to the TELINK.
The door Web Server can be connected online internet and medium a link dns the TELINK can be questioned with an univocal name of station rather than the IP address (example: from internet radio_rvr_spa.it rather than xxx.xxx.xxx.xxx).
The TELINK is contained in a screening metallic playpen to easily install on bar omega or 1 unit rack for the TELINK-SNMP2 version. All the signals and the feeding are endowed with connectors for a rapids substitution. The feeding is galvanic isolated and the signals filtered for having a high immunity from the radio frequency troubles. The fuse is restoring auto and the entry it foresees a varistore of protection from the extratensionis. The retention of the data in memory dates is done with maxi life boundless capacitor rather than batteries to the NiCd that they ask for maintenance in the time.
In the façade there are nine led for a complete synoptic on the traffic of the serial lines and the diagnosis of the typology of error with three red led. TELINK is endowed with watchdog hardware for automatic reset in case of anomalous stop of the processor or lowering under the limit of the tension of feeding.
The TELINK is endowed with a formality “simulation” that it allows to a system ANTLAN or BURK to regularly be connected to the TELINK reading some virtual (test of the protocol and the net) values.

Telemetry interface

Broadcast TLC2000-T Telemetry and Changeover A4

TELINK-SNMP2 Interface

 

Functional specifications

Working parameters management

Telecon software connection
All working parameters reading
ON/OFF state management
Change transmitter power management
Nominal and low power state management
Mains and alarm management
Custom alarms management
Electromechanical telecontrol and telealert
Modem GSM (/MODGSM) support
Modem PSTN Fixed-line (/MODPSTN) support

SMS alert

SMS alarms alert
SMS alarms restore alert
Receive commands via SMS
Registration identification data and SMS sending
Alarms alert through data call

Interface controls

WEB interface support (TCPIP-INT series)
SNMP interface support (TELINK-SNMP2)
ANTLAN & BURK interface support (TELINK-C1)

On board telemetry without modem (TLC)On board telemetry with GSM modemExternal customizable telemetry TLC2000 Professional seriesExternal customizable telemetry  TLC300/T2 Easy maintenance modelExternal telemetry without GSM modem RDMODSER-FM Professional model
Red RightRed RightRed RightRed RightRed Right
Red RightRed RightRed Right
Red RightRed RightRed RightRed RightRed Right
Red RightRed RightRed RightRed RightRed Right
Red RightRed RightRed Right
Red RightRed RightRed RightRed RightRed Right
Red RightRed Right
Red RightRed RightRed RightRed RightRed Right
Red RightRed RightRed RightRed Right
Red RightRed RightRed RightRed RightRed Right
Red RightRed RightRed Right
Red RightRed RightRed RightRed RightRed Right
Red Right
Red RightRed RightRed RightRed RightRed Right
Red RightRed Right
Red RightRed RightRed RightRed Right
Red RightRed RightRed RightRed Right

External telemetry with GSM modem RDMODGSM-FM Professional series

Telemetry and changeover SCMLCD1+1 Series for double exciters transmittersTelemetry and changeover SCMLCDN+1 series for multi transmittersTelemetry and changeover SCMLCD1+1 TCS model for double exciters transmit

Telemetry and changeover SCM6/1 model for multi transmitters

Red RightRed RightRed RightRed Right
Red Right
Red RightRed RightRed RightRed RightRed Right
Red RightRed RightRed RightRed Right
Red Right
Red RightRed RightRed RightRed Right
Red RightRed Right
Red RightRed Right
Red RightRed RightRed RightRed Right
Red RightRed RightRed Right
Red RightRed RightRed RightRed Right
Red Right
Red RightRed RightRed RightRed Right
Red Right
Red RightRed RightRed RightRed Right
Red RightRed RightRed Right
Red RightRed RightRed Right
Telemetry unit & telemetry interface technical specification
TLC 300/T2TLC 2000/(T1…T6)RDMODSER-FM RDMODGSM-FM
ParametersValuesValuesValues
GENERALS
Primary Power100 – 120 – 220 – 240 VAC ±15% or 24 VDC115 / 230 VAC ±15%
Phisical Dimensions (W x H x D)483 x 44 x 263 mm483 x 88 x 263 mm483 x 44 x 263 mm
Weight4,3 kg7 kg6,5 kg
Environmental working temperature-10 to + 50 °C
CoolingForced with internal fans
INPUT
Analog8 analog inputs for each T card maximum 2 cards8 analog inputs for each T card maximum 6 cards
Digital/Analog16 digital inputs for each T card maximum 2 cards16 digital inputs for each T card  maximum 6 cards
OUTPUTS
Relay8 Relayoutputs for each T card maximum 2 T cards8 Relayoutputs for each T card  maximum 6 T cards
INTERFACE
RS232Yes
RS485Yes
IIC BUSYes
RJ 45 (LAN) 
STANDARD COMPLIANCE
SafetyEN60215:1997
EMCEN 301 489-11 V1.4.1
Spectrum OptimizationEN 301 511 V9.0.2

All pictures are RVR’s property and they are only indicative and not binding. The pictures can be modified without notice.
These are general specifications. They show typical values and are subject to change without notice.

Ordering information

Broadcast TLC2000-T Telemetry and Changeover B1 Broadcast TLC2000-T Telemetry and Changeover B2
Img.1                                                        Img.2

Broadcast TLC2000-T Telemetry and Changeover B3 Broadcast TLC2000-T Telemetry and Changeover B4
Img.3                                                        Img.4

Broadcast TLC2000-T Telemetry and Changeover B5 Broadcast TLC2000-T Telemetry and Changeover B6
Img.5                                                        Img.6

Broadcast TLC2000-T Telemetry and Changeover B7 Broadcast TLC2000-T Telemetry and Changeover B8
Img.7                                                        Img.8

Telemetry unit version
CodeDescriptionHE Unit
RDMODSER-FMTelemetry unit fully digital for single exciter – without modem 1 HE
Img.1RDMODGSM-FMTelemetry unit fully digital for single exciter1 HE
Img.2TLC300/T2Telemetry unit with Nr 1 I/O base card on board1 HE
Img.3TLC2000/T1Professional telemetry unit with Nr 1 I/O base card on board2 HE
Img.4TLC2000/T2Professional telemetry unit with Nr 1 I/O additional card on board 2 HE
Img.5TLC2000/T3Professional telemetry unit with Nr 2 I/O additional cards on board 2 HE
Img.6TLC2000/T4Professional telemetry unit with Nr 3 I/O additional cards on board 2 HE
Img.7TLC2000/T5Professional telemetry unit with Nr 4 I/O additional cards on board 2 HE
Img.8TLC2000/T6Professional telemetry unit with Nr 5 I/O additional cards on board 2 HE
TCPINT-PTX-16 TCPIPINT-DDS TCPINT-TEXTELINK-C1TELINK-SNMP2
ValuesValuesValues
10-30 V DC230 VAC ±15%
73 x 33 x 95 mm150 x 40 x 100 mm483 x 44 x 300 mm
0,3 kg0,8 kg4 kg
-10 to + 50 °C
Yes
Yes
YesYes
EN60215:1997 
EN 301 489-11 V1.4.1 

CE note  99/5/CE Revision: 03/10

Telemetry interface
CodeDescriptionHE Unit
TCPIPINT-PTX-16Web interface for PTX 16 bit exciter series Box
TCPIPINT-DDS Web interface for PTX DDS exciter series Box
TCPIPINT-TEX Web interface for TEX exciter series Box
TELINK-C1Interfaccia di telemetria protocollo ANTLAN/BURK Box
TELINK-SNMP2 Interfaccia di telemetria RVR/SNMP 1 HE

 RVRRVR Elettronica S.p.A.
Via del Fonditore, 2/2c
Zona Industriale Roveri • 40138 Bologna • Italy
Phone: +39 051 6010506 • Fax: +39 051 6011104
e-mail: info@rvr.it • web: http://www.rvr.it

ISO 9001:2000 certified since 2000
RINA ISO 9001.2000

Documents / Resources

Broadcast TLC2000-T Telemetry and Changeover [pdf] Owner's Manual
TLC2000-T Telemetry and Changeover, TLC2000-T, Telemetry and Changeover, Changeover

References