BITMAIN S19e XP Hyd Algorithm With Maximum Hashrate

Product Information
Specifications
| Product Glance | Value |
|---|---|
| Model | S19e XP Hyd. |
| Sub Version | |
| Crypto algorithm/coins | SHA256|BTC/BCH/BSV |
| Typical hashrate, TH/s(1-1) | 251 |
| Power on wall @35(1-2), Watt(1-1) | 240 |
| Power efficiency on wall@35(1-2), J/T(1-1) | 10 |
Frequently Asked Questions (FAQ)
- Q: What is the recommended coolant for the S19e XP Hyd.?
A: The recommended coolants are Antifreeze, Pure water, or Deionized water based on the specified pH values.
Specification
| Product Glance | Value | |
| Model | S19e XP Hyd. | |
| Sub | 251T | 240T |
| Version | 10 | |
| Crypto algorithm/coins | SHA256|BTC/BCH/BSV | |
| Typical hash rate, TH/s(1-1) | 251 | 240 |
| Power on wall @35℃(1-2), Watt(1-1) | 5522 | 5280 |
| Power efficiency on wall@35℃(1-2), J/T(1-1) | 22 | |
Detailed Characteristics
| Detailed Characteristics | Value |
| Power supply | |
| Phase | 3 |
| Input voltage, Volt(2-1) | 380~415 |
| Input frequency range, Hz | 50~60 |
| Input max current, Amp | 12 |
| Hardware configuration | |
| Network connection mode | RJ45 Ethernet 10/100M |
| Server size (length*width*height, w/o package), mm | 410*170*209 |
| Server size (length*width*height, with package), mm | 570*316*430 |
| Net weight, kg | 12.8 |
| Gross weight, kg | 14.1 |
| Environment requirements | |
| Inlet coolant temperature, °C | 20~50 |
| Coolant flow, L/min | 8.0~10.0 |
| Coolant pressure, bar | ≤3.5 |
| Working Coolant (2-2) | Antifreeze/ Pure water/ Deionized water |
| Coolant pH value | Antifreeze: 7.0~9.0 Prue water: 6.5~7.5
Deionized water:8.5~9.5 |
| Diameter of Coolant pipe connector, mm | OD10 |
| Storage temperature, °C | -20~70 |
| Operation humidity(non-condensing), RH | 10~90% |
Notes:
- The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by 3%, and the actual power on wall and power efficiency on wall fluctuate by 5%.
- Inlet coolant temperature.
- Caution: Wrong input voltage may cause server damaged.
- For detailed working coolant use and maintenance instructions, please refer to “ANTSPACE HK3 Water Cooling Container & Dry-Wet Tower Product Manual”, Chapter 9, Article 3, Point 6, “Maintenance of Coolant”!
Performance Curve
- Hashrate vs. Inlet Coolant Temperature.

- Power Efficiency vs. Inlet Coolant Temperature.