Wiltec 65829 (18600 L/h)

Wiltec Pool Pump 18600 L/h User Manual

Model: 65829 (18600 L/h) | Brand: Wiltec

1. Уводзіны

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Wiltec Pool Pump, model 65829. This pump is designed for circulating and filtering water in pools ranging from 74 to 110 cubic meters, offering a high flow rate of 18,600 liters per hour and a maximum head of 13 meters. It is compatible with sand filter systems and features an integrated pre-filter for enhanced protection.

Wiltec Pool Pump 18600 L/h installed next to a swimming pool

Малюнак 1: Wiltec Pool Pump 18600 L/h in a typical pool setup. This image shows the pump connected to a pool system, highlighting its compact design and connection points.

2. Інфармацыя па бяспецы

Read all safety instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury. Keep this manual for future reference.

  • Заўсёды адключайце помпу ад электрасеткі перад выкананнем любога тэхнічнага абслугоўвання або чысткі.
  • Ensure the electrical installation complies with local regulations and is protected by a Residual Current Device (RCD) with a tripping current not exceeding 30 mA.
  • Не выкарыстоўвайце помпу, калі пашкоджаны шнур харчавання або вілка.
  • The pump must be installed on a stable, level surface, protected from direct sunlight and adverse weather conditions.
  • Ensure adequate ventilation around the pump motor to prevent overheating.
  • This pump is designed for fresh water only, with a liquid temperature range of 0-35°C. Do not use with corrosive, flammable, or explosive liquids.

For detailed safety guidelines, please refer to the official Safety Information PDF document: Інфармацыя па бяспецы (PDF)

3. Камплектуючыя і памеры прадукту

The Wiltec Pool Pump consists of a robust motor, a pump housing with an integrated pre-filter, and inlet/outlet connections. Understanding the dimensions is crucial for proper installation and space planning.

Technical drawing showing the dimensions of the Wiltec Pool Pump

Малюнак 2: Product Dimensions. This diagram illustrates the pump's overall length (580 mm), width (242 mm), and height (367 mm), along with specific measurements for connections and components.

Асноўныя кампаненты ўключаюць:

  • Pre-filter Basket: Located at the inlet, designed to capture debris larger than 3.9 mm.
  • Матор: 750W copper-wound motor with thermal overload protection.
  • Корпус помпы: Трывалая пластыкавая канструкцыя.
  • Уваход/выхад: Standard connections for pool hoses.

4. Настройка і ўстаноўка

Proper installation is vital for the pump's performance and longevity. It is recommended that installation be performed by a qualified technician.

  1. Размяшчэнне: Position the pump on a firm, level surface as close to the pool as possible to minimize suction lift. Ensure it is below the water level if possible for self-priming.
  2. Мантаж: Secure the pump to the surface using appropriate fasteners to prevent vibration and movement.
  3. Сантэхнічныя злучэнні: Connect the pump's inlet to the pool skimmer/main drain line and the outlet to the sand filter and return lines. Ensure all connections are watertight using thread sealant tape or appropriate gaskets.
  4. Электрычнае падключэнне: Connect the pump to a dedicated, properly grounded electrical circuit protected by an RCD. Verify that the power supply voltage matches the pump's requirements (230V, 50Hz).
  5. Грунтоўка: Before first use, fill the pre-filter housing with water to ensure the pump is primed. This prevents dry running and potential damage.

5. Інструкцыя па эксплуатацыі

Пасля ўстаноўкі і залівання помпа гатовы да працы.

  1. Запуск помпы: Ensure all valves are open and the pre-filter is full of water. Connect the pump to the power supply. The pump will start circulating water.
  2. Маніторынг прадукцыйнасці: Observe the water flow and pressure gauge (if installed on your filter system) to ensure optimal operation. The pump is designed for a maximum flow rate of 18,600 L/h and a maximum head of 13 meters.
  3. Дыяпазон тэмператур: The pump is designed to operate with liquid temperatures between 0°C and 35°C. Operating outside this range may damage the pump.
  4. Спыненне помпы: Disconnect the pump from the power supply. Close any necessary valves to prevent water backflow.
Diagram showing optimal flow rate and head for the Wiltec Pool Pump

Малюнак 3: Optimal Performance. This image highlights the pump's maximum head of 13 meters and maximum flow rate of 18,600 L/h, along with the recommended liquid temperature range of 0-35°C.

6. Тэхнічнае абслугоўванне

Рэгулярнае тэхнічнае абслугоўванне забяспечвае даўгавечнасць і эфектыўную працу вашага басейна.

  • Папярэдняя ачыстка фільтра: The integrated pre-filter collects debris such as leaves, twigs, gravel, and hair. Regularly inspect and clean the pre-filter basket to maintain optimal flow and prevent pump strain. To clean, disconnect power, open the pre-filter lid, remove the basket, empty debris, and rinse thoroughly. Reassemble, ensuring the O-ring is properly seated and the lid is securely tightened.
  • Image showing the pre-filter of the Wiltec Pool Pump collecting debris

    Малюнак 4: Pre-filter Function. This image demonstrates how the pump's pre-filter effectively captures various types of debris, such as leaves, twigs, gravel, and hair, protecting the pump's internal components.

  • Праверка рухавіка: Periodically check the motor for any unusual noises or excessive heat. The copper-wound motor is designed for stable operation and includes thermal overload protection.
  • У разрэзе view of the Wiltec Pool Pump motor showing copper windings

    Малюнак 5: Robust Motor Design. This image provides a view of the pump's copper-wound motor, emphasizing its stable operation and built-in protection against overheating and overload.

  • Генеральная ўборка: Трымайце знешнія паверхні помпы чыстымі і без бруду і смецця.
  • Зімоўка: In regions with freezing temperatures, drain the pump completely and store it in a dry, frost-free location during the off-season to prevent damage.

7. Выпраўленне непаладак

Калі ў вас узніклі праблемы з помпай, звярніцеся да наступных распаўсюджаных праблем і іх рашэнняў:

праблемаМагчымая прычынаРашэнне
Помпа не запускаеццаNo power; tripped circuit breaker; motor overload protection activatedCheck power supply and connections; reset circuit breaker; allow motor to cool down if overheated.
Нізкі расход вадыClogged pre-filter basket; air leak in suction line; low water level in pool; clogged impellerClean pre-filter basket; check all suction line connections for leaks; ensure adequate pool water level; inspect impeller for blockages.
Помпа працуе, але вада не цячэPump not primed; air lock; closed valve in suction linePrime the pump by filling the pre-filter with water; check for and release air locks; ensure all valves are open.
Незвычайны шум або вібрацыяAir in system; debris in impeller; loose mountingCheck for air leaks and prime pump; clean impeller; tighten mounting bolts.

If problems persist after attempting these solutions, contact a qualified service technician or Wiltec customer support.

8. Тэхнічныя характарыстыкі

СпецыфікацыяКаштоўнасць
ВытворцаВільтэк
Нумар мадэлі65829
Хуткасць патоку (макс.)18,600 л/гадз
Ватtage750 Вт
Макс Хэд13 метраў
Рэкамендаваны аб'ём басейна74-110 м³
Памеры прадукту (Д х Ш х У)58 х 24.7 х 36.7 см
Вага прадмета10.25 кг
МатэрыялПластыкавыя
КолерСіні, чорны
Тып харчаваннярубчатая
Тэмпературны дыяпазон вадкасці0-35°C

9. Гарантыя і падтрымка

Каб атрымаць інфармацыю аб гарантыі, тэхнічнай падтрымцы або абслугоўванні, звярніцеся непасрэдна да прадаўца або вытворцы. Захоўвайце чэк аб куплі як пацверджанне пакупкі.

A Certificate of Conformity is available for this product: Certificate of Conformity (PDF)

© 2026 Wiltec. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.