antaira LMX-0800 Series 8-Port Industrial Managed Ethernet Switch Installation Guide www.Antaira.com Package Check List The package contains the…
Industrial 6G + 4GF L2+/L3
Managed Ethernet Switch
Quick Installation Guide
8010GX4 is designed for industrial environments requiring high security and high-quality Ethernet/Fiber communication, such as industrial automation, road traffic control, etc. The switch provides 10-port full-gigabit Ethernet including 6-port Gigabit RJ45 and 4-port 100M/1G SFP. Full Gigabit capability and rugged industrial design ensures system high performance and reliability in harsh environments. For convenient traffic control and zero packet loss data transmission, the switch offers contemporary management and security functions.
8010GX4 | |
10/100/1000Base-T | 6 |
100/1000Base SFP | 4 |
Power input | 24VDC (10~60VDC) |
Optional Accessory (for detailed information please refer to the Datasheet):
DIN Rail mount
To mount the switch on the DIN Rail track, insert the upper end of the DIN‐Rail clip into the back of the DIN‐Rail track from its upper side and lightly push the bottom of the DIN‐Rail clip into the track. The DIN Rail should comply with DIN EN50022 standard. Using wrong DIN rail may cause unsafe installation.
Grounding Screw
For avoiding system damage by noise or electric shock, establish a direct connection between the grounding screw and the grounding surface prior to connecting devices.
Wiring the Power Input
Wiring the Relay Output
The relay output of the 2-pin terminal block connector are used to detect userconfigured events. The two wires attached to the fault contacts form a close circuit when a user-configured event is triggered. If a user-configured event does not occur, the fault circuit remains opened.
Wiring the Digital Input
To wire the DI on the Terminal block, loosen screws by screwdriver on the terminal block connector, insert the positive and negative wires into the V+ and V- contact and then tighten screws after the DI wire is connected.
Console/Reset Port
The switch provide Reset and RS232 console for out of band configuration. The default baud rate setting is 115,200, N, 8, 1. Reset button allows you to reset switch or reload to factory default (>7 sec). For further configurations, please refer to User Manual.
Parity: None / Data Bit: 8 / Stop Bit: 1
System LED Indication
LED | Status | Description |
PWR (P1/P2) | Green On | DC-IN Power is On |
Off | No Power in DC-IN | |
Alarm (DO) | Red On | Any failures in port link, ping, power, DO and DI State by SW control |
Off | No failure occurs |
Port LED Indication
LED | Status | Description |
RJ45 Port | Green On | Links established |
Green Blinking | Packets transmitting/receiving | |
Green Off | Link is inactive | |
Amber On | Link Speed 1000M | |
Amber Off | Link Speed 100M | |
SFP Port | Green On | Links established |
Green Blinking | Packets transmitting/receiving | |
Green Off | Link is inactive | |
Amber On | Link Speed 1000M | |
Amber Off | Link Speed 100M |
Safety Precautions
This device supports both in-band and out-of-band network management.
The user can either configure the device through the user-friendly Web/HTTPS management or remotely manage the device through the network by console management or Telnet/SSH. network by console management or Telnet/SSH.
SSH (Secure Shell)
The router supports SSH console and can be connected via command-line interface access remotely. SSH connection can secure all the configuration commands that sent to the switch.
SSH Client
There are many free, sharewares, trials or charged SSH clients you can find on the internet.
◆ For further feature configurations, please refer to User Manual.
Support
At AVCOMM, you can use the online service forms to request the support. The submitted forms are stored in server for AVCOMM team member to assign tasks and monitor the status of your service. Please feel free to write to sales@avcomm.cn if you encounter any problems.
Warranty
5-year Global warranty are available for AVCOMM products assuring our customers that the products shall remain free from defects in workmanship or materials and conform in all material respects to AVCOMM specifications, or purchasers supplied and accepted specifications. The warranty is limited to the repair and/or replacement, at AVCOMM sole discretion, of the defective product during its warranty period. The customer must obtain a Return Merchandise Authorization (RMA) approval code prior to returning the defective Product to AVCOMM for service. The customer agrees to prepay shipping charges, to use the original shipping package or equivalent, and to ensure the product or assume the risk of loss or damage in transit. repaired or replaced products are warranted for ninety (90) days from the date of repair or replacement, or for the remainder of the original product’s warranty period, whichever is longer.
Disclaimer
AVCOMM 8010GX4 Industrial 6G + 4GF L2+/L3 Managed Ethernet Switch [pdf] Installation Guide 8010GX4 Industrial 6G 4GF L2 L3 Managed Ethernet Switch, 8010GX4, Industrial 6G 4GF L2 L3 Managed Ethernet Switch, Managed Ethernet Switch, Ethernet Switch |
2 1-2 Inch Tranquil Light Filtering Sheer Shades Installation Guide 2 1/2" Tranquil Light Filtering…
GR 48 Novinka 48 user manual CONTENT General warnings and safety instructions .................................. 3 Warning…
FAN5856 Thermostat UT-M1 INSTALLATION INSTRUCTIONS Ultecon Thermostat UT-M1 Order Code: FAN5856 1 - Cover Removal…
Hiway 15 PIR Motion Sensor Auto-Adjust Solar Light USER MANUAL Hiway 15 PIR Motion Sensor…
m18 R1 Gaming Laptop Alienware m18 R1 Setup and Specifications Regulatory Model: P51E Regulatory Type:…
ST6000 Wire To RCA Adapter Converter ST6000 REMOTE high signal converter MANUAL DO USUÁRIO USER…