GOPLUS GQ22175FR

GOPLUS Reversible Split Air Conditioner 9000 BTU (Model GQ22175FR) User Manual

Model: GQ22175FR

1. Introduction

This manual provides essential information for the safe installation, operation, and maintenance of your GOPLUS Reversible Split Air Conditioner. This unit is designed to provide efficient heating and cooling for your home, featuring 7 distinct operating modes and advanced inverter technology for optimal comfort and energy savings. Please read this manual thoroughly before using the appliance and keep it for future reference.

Family relaxing in a room with the GOPLUS air conditioner providing cool air.

Image: The GOPLUS air conditioner providing comfortable air in a living space, illustrating its comfort-enhancing capabilities.

2. Safety Instructions

Important: Failure to follow these safety instructions may result in electric shock, fire, serious injury, or death.

  • Before installation, it is imperative to consult local authorities and neighbors regarding regulations and potential impacts.
  • Professional installation is mandatory. Do not attempt to install the unit yourself. Contact and use a qualified professional for this operation.
  • The air conditioner is not equipped with a power plug. Professional wiring is required to ensure safe and correct electrical connection.
  • Ensure the power supply matches the unit's specifications (220-240 V~ 50HZ).
  • Do not insert fingers or objects into the air inlet or outlet.
  • Keep the unit away from flammable materials and heat sources.
  • Do not operate the unit with wet hands.
  • In case of abnormal operation, strange sounds, or smoke, immediately turn off the unit and disconnect the power supply. Contact a qualified technician.

3. Package Contents

Carefully unpack the box and ensure all items are present and undamaged. If any items are missing or damaged, contact your retailer.

  • 1 x Reversible Air Conditioner Unit Set (Indoor and Outdoor Units)
  • 2 x Copper Connection Pipes (one for gas, one for liquid)
  • 1 x Communication Wire
  • 2 x Drain Pipes
  • 1 x Power Cable
  • 1 x Insulating Foam
  • 1 x Remote Control
  • 1 x Sealant
  • 1 x Adhesive Tape
  • 1 x Drain Elbow

4. Setup and Installation

Reminder: Installation must be performed by a qualified professional.

The GOPLUS Reversible Split Air Conditioner is designed for through-the-wall installation. The professional installer will handle the placement of both the indoor and outdoor units, ensuring proper connection of the copper pipes, communication wire, drain pipes, and electrical wiring.

Unit Dimensions:

  • Indoor Unit: 78 cm (L) x 20 cm (W) x 25 cm (H)
  • Outdoor Unit: 73 cm (L) x 28 cm (W) x 45.5 cm (H)
GOPLUS outdoor air conditioner unit operating in extreme temperatures, cooling at 53°C and heating at -20°C.

Image: The outdoor unit demonstrating stable performance in extreme weather conditions, capable of cooling at 53°C and heating at -20°C.

5. Operating Instructions

Your air conditioner offers various modes and settings for personalized comfort. All functions are controlled via the provided remote control.

Operating Modes:

Select from seven distinct operating modes to suit your needs:

  • Automatic: The unit automatically selects the appropriate mode (cooling or heating) based on the ambient temperature.
  • Cooling: Provides rapid cooling, reaching desired temperatures in approximately 30 seconds.
  • Heating: Provides rapid heating, reaching desired temperatures in approximately 60 seconds.
  • Dehumidification: Reduces humidity in the room without significant temperature change.
  • Ventilation: Circulates air without cooling or heating.
  • Sleep: Adjusts temperature and fan speed for quiet, comfortable sleep.
  • Eco-saving: Optimizes performance to reduce energy consumption.

Additional Functions:

  • Digital Display: Shows current settings and temperature.
  • Air Deflector Oscillation: Ensures uniform air distribution throughout the room.
  • Health Mode: Activates specific settings for improved air quality.
  • Sensation Regulation: Adjusts operation based on perceived comfort.

Air Speed Regulation:

The unit offers eight adjustable fan speed levels:

  • Automatic
  • Silent
  • Low
  • Low-Medium
  • Medium
  • Medium-High
  • High
  • Turbo

Timer Function:

Use the timer to program the automatic shutdown of the appliance, enhancing convenience and energy saving.

Quiet Operation:

The indoor unit operates at a low noise level of 22 dB. Combined with the Sleep mode and silent speed, it creates a calm environment. The display off function minimizes light disturbance for peaceful sleep.

Diagram showing rapid cooling in 30 seconds and rapid heating in 60 seconds, with a coverage area of 24 m².

Image: Illustration of the air conditioner's rapid cooling (30s) and heating (60s) capabilities, covering an area of up to 24 m².

6. Maintenance

Regular maintenance ensures optimal performance, air quality, and extends the lifespan of your air conditioner.

Self-Cleaning Function:

The unit is equipped with an auto-cleaning function. It is recommended to activate this function every three months to eliminate accumulated dirt on the indoor evaporator, ensuring a healthier environment.

Filter Cleaning:

The air filter is removable and washable. It is advised to clean the filter every 3 to 6 months to maintain pure and fresh air, and to preserve a healthy environment for all occupants.

Image showing the GOPLUS air conditioner with an emphasis on its self-cleaning function and removable, washable filters.

Image: The air conditioner highlighting its self-cleaning feature and easily removable, washable filters for improved air quality and maintenance.

7. Troubleshooting

If you encounter issues with your air conditioner, please refer to the following general troubleshooting tips. For complex problems, contact a qualified technician.

  • Unit does not turn on: Check if the power cable is properly connected and if there is power to the outlet. Ensure the remote control batteries are not depleted.
  • Insufficient cooling/heating: Verify that the selected mode is correct and the temperature setting is appropriate. Ensure air filters are clean and there are no obstructions to the indoor or outdoor unit's airflow. Check if doors and windows are closed.
  • Unusual noises: Minor noises during operation are normal. If you hear loud or unusual sounds, turn off the unit and contact a professional.
  • Water leakage: Check if the drain pipe is properly installed and not blocked.

8. Specifications

FeatureSpecification
BrandGOPLUS
Model NumberGQ22175FR
Cooling Capacity9000 BTU
Cooling Power1380 W
Heating Power1552 W
Voltage220-240 V~ 50HZ
Coverage Area14-22 m²
Temperature Adjustment Range16-31 ℃
Indoor Noise Level22 dB
Energy EfficiencyA++
Refrigerant TypeR32
Total Net Weight29.5 kg
ColorWhite
MaterialMetal, Aluminum, Copper, ABS
Annual Energy Consumption2156 kWh/year
Country of OriginChina
Installation TypeThrough the wall

9. Warranty and Support

Warranty Information: No specific warranty details are provided in this manual. Please refer to your purchase agreement or contact your retailer for information regarding the product warranty.

Technical Support: For technical assistance, service, or any questions not covered in this manual, please contact the seller 'Augenstern24' or your professional installer who performed the installation.

Ask a question about this manual