1. Introduction

The JXRSKJ DC Relay Timer Module is a high-performance, programmable timer switch designed for precise control of electrical devices. It features a wide input voltage range (5V to 36V) and a clear LED display for easy monitoring. This module is ideal for controlling DC motors, LED strips, micro pumps, and solenoid valves in various applications, including home automation, industrial control, and DIY projects. Its advanced control unit ensures high stability, low power consumption, and quiet operation without the wear associated with traditional electromagnetic relays.

2. Product Overview

This module utilizes a parallel MOS output structure, providing high current capacity and performance. It can handle operating currents up to 15A and power up to 400W at room temperature. The design prioritizes durability and reliability, offering a longer service life compared to conventional relay modules.

  • High Performance & Durability: Advanced control chip for stability and extended lifespan.
  • Wide Voltage Compatibility: Operates from 5V to 36V DC, suitable for diverse devices.
  • Quiet Operation: No noise or sparking during switching, ideal for sensitive environments.
  • Unlimited Switching Cycles: Supports rapid and frequent on/off operations.
  • LED Display: Provides clear status indication for easy operation.
  • MOS Output: Handles high currents (up to 15A) and power (up to 400W).
Close-up view of the JXRSKJ DC Relay Timer Module showing the LED display, control buttons, and screw terminals.

Image: Detailed view of the module's LED display and components.

Dimensions of the JXRSKJ DC Relay Timer Module, showing length 60mm (2.36 in), width 34mm (1.34 in), and height 12mm (0.47 in).

Image: Product dimensions and size comparison with a hand.

3. Setup and Wiring

The module features user-friendly screw terminal connections for quick and secure wiring. Ensure all connections are firm before applying power.

3.1 Terminal Connections

  • VCC: Positive power supply input (5V-36V DC).
  • GND: Negative power supply input.
  • OUT+: Positive output to the controlled device.
  • OUT-: Negative output to the controlled device.

Important: The output voltage matches the input voltage. Connect your load (e.g., motor, LED strip) between OUT+ and OUT-.

3.2 Wiring Diagram Example

A person wiring the JXRSKJ DC Relay Timer Module with a screwdriver, showing connections to screw terminals.

Image: Example of wiring the module for easy installation.

Multiple installation scenarios for the JXRSKJ DC Relay Timer Module, including integration into an electrical box and breadboard setup.

Image: Various installation examples of the timer module.

After wiring, apply power to the VCC and GND terminals. The LED display will illuminate, indicating the module is powered on.

4. Operating Instructions

The module features three control buttons: SET, UP, and DOWN. These buttons are used to configure the operating mode and time parameters.

4.1 Basic Button Functions

  • SET Button:
    • Short press: Enters parameter setting mode or cycles through parameters within a mode.
    • Long press: Enters mode selection menu.
  • UP Button: Increases the value of the currently selected parameter.
  • DOWN Button: Decreases the value of the currently selected parameter.

4.2 Operating Modes (Example)

While specific modes may vary, common timer relay functions include:

  • P1.1: Delay ON (Trigger activates relay after a set time).
  • P1.2: Delay OFF (Trigger activates relay, then deactivates after a set time).
  • P2.1: Cycle Timer (Relay ON for T1, OFF for T2, repeats N times).
  • P3.1: Infinite Cycle (Relay ON for T1, OFF for T2, repeats indefinitely).

4.3 Setting Parameters

  1. Enter Mode Selection: Long press the SET button until the display shows a mode code (e.g., "P1.1").
  2. Select Mode: Use UP and DOWN buttons to navigate through available operating modes.
  3. Confirm Mode: Short press SET to select the desired mode. The display will then show the first parameter (e.g., "OP" for ON time).
  4. Adjust Parameters: Use UP and DOWN to change the value of the current parameter. Short press SET to move to the next parameter (e.g., "CL" for OFF time, "LOP" for loop count).
  5. Save Settings: After adjusting all parameters for the selected mode, long press SET to save the settings and exit the programming menu. The module will then enter its operational state.

The LED display will show the current time countdown or status during operation.

5. Maintenance

The JXRSKJ DC Relay Timer Module is designed for long-term, reliable operation with minimal maintenance.

  • Cleaning: Keep the module free from dust and debris. Use a soft, dry cloth for cleaning. Avoid using liquids or abrasive cleaners.
  • Environment: Operate the module within its specified temperature and humidity ranges. Avoid exposure to extreme temperatures, moisture, or corrosive environments.
  • Connections: Periodically check screw terminal connections to ensure they remain secure. Loose connections can lead to intermittent operation or damage.

6. Troubleshooting

If you encounter issues with your module, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Module does not power on / LED display is off.No power, incorrect wiring, or power supply voltage is too low.
  • Verify power supply connections to VCC and GND.
  • Ensure input voltage is within the 5V-36V range. Note: Some modules may require slightly above 5V (e.g., 6V) to start reliably.
  • Check for loose wires or short circuits.
Module powers on but does not control the device.Incorrect output wiring, load exceeding module capacity, or incorrect program settings.
  • Confirm the load is correctly connected to OUT+ and OUT-.
  • Ensure the load's current and power requirements do not exceed 15A/400W.
  • Review the operating mode and parameter settings (Section 4).
Inconsistent timing or unexpected behavior.Power fluctuations, electromagnetic interference, or incorrect parameter settings.
  • Ensure a stable power supply.
  • Relocate the module away from strong electromagnetic fields if possible.
  • Re-enter and verify all timing parameters.

7. Specifications

FeatureDetail
BrandJXRSKJ
ModelJIDIANQIMOKUAI-35
Input VoltageDC 5V - 36V
Output TypeMOS Output (Output voltage matches input voltage)
Max. Operating Current15A (at room temperature)
Max. Power400W
Display TypeLED
Included ComponentsDC relay timer module
UPC662987487214

8. Warranty and Support

For warranty information or technical support, please refer to the retailer or manufacturer's official website. Keep your purchase receipt for any warranty claims.

© 2026 JXRSKJ. All rights reserved.

Documents - JXRSKJ – JIDIANQIMOKUAI-35

no relevant documents

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.