1. Introduction
This manual provides essential information for the safe installation, operation, and maintenance of your OELFFOW 100A Generator Transfer Switch. This device is designed to safely transfer electrical load between a utility power source and a standby generator, ensuring continuous power supply to your electrical equipment. Please read this manual thoroughly before installation and use.
2. Safety Information
WARNING: Electrical shock hazard. Installation and servicing of this transfer switch must be performed by a qualified electrician in accordance with all national and local electrical codes. Failure to follow these instructions can result in serious injury or death.
- Always disconnect all power sources (utility and generator) before working on the transfer switch.
- Ensure proper grounding of the transfer switch.
- Do not operate the switch if it is damaged or appears to be malfunctioning.
- Keep the enclosure door closed and secured during operation to prevent accidental contact with live parts.
- This transfer switch is rated for 100A and is suitable for 120/240/450V systems. Do not exceed these ratings.
3. Product Overview
The OELFFOW 100A Generator Transfer Switch is a general-duty, double-throw safety switch designed for reliable power transfer. It features a robust construction and is compliant with NEMA 3R standards, making it suitable for both indoor and outdoor installations.
Key Features:
- Current Rating: 100 Amperes
- Voltage Compatibility: 120V, 240V, 450V
- Power Capacity: Up to 45000W
- Enclosure Rating: NEMA 3R for indoor/outdoor use, providing protection against rain, sleet, snow, and external ice formation.
- Arc Extinguishing Cover: Designed to effectively prevent electric arcs, enhancing safety and extending equipment lifespan.
- Durable Construction: Made with a cold-rolled steel shell, epoxy insulation pad, and T2 electrolytic copper components for longevity.

Image 3.1: Internal view of the transfer switch showing the arc extinguishing cover design. This feature helps prevent electrical arcs, ensuring safety and extending the equipment's operational life.

Image 3.2: Detailed view highlighting the premium and durable construction of the transfer switch, including the cold-rolled steel shell, epoxy insulation pad, and T2 electrolytic copper components.

Image 3.3: The NEMA 3R compliant enclosure ensures the transfer switch can withstand various extreme weather conditions, including rain, wind, and snow, making it suitable for outdoor installation.
4. Setup and Installation
Installation of this transfer switch requires electrical expertise. It is strongly recommended that a licensed electrician performs the installation to ensure compliance with all applicable electrical codes and safety standards.
Mounting:
The OELFFOW transfer switch is designed for wall mounting. Select a suitable location that is easily accessible for operation and maintenance, yet protected from potential physical damage. Ensure the mounting surface is capable of supporting the weight of the unit (approximately 11.42 pounds).
Wiring:
Refer to the wiring diagram below for proper electrical connections. All wiring must conform to local and national electrical codes. Use appropriately sized conductors for 100A service. Ensure all connections are tight and secure.

Image 4.1: Detailed wiring diagram for the OELFFOW 100A Generator Transfer Switch. This diagram illustrates connections for LINE1 (utility), LINE2 (generator), LOAD, and the ground bar. It also shows the non-fusible two-pole configuration with a neutral for two sources or two loads.
- Connect the utility power source to the designated 'LINE1' terminals.
- Connect the generator power source to the designated 'LINE2' terminals.
- Connect the electrical load (house/equipment) to the 'LOAD' terminals.
- Ensure the ground bar is properly connected to the main grounding electrode system.
5. Operating Instructions
The OELFFOW 100A Generator Transfer Switch operates manually with an ON-OFF-ON switching mechanism. This allows for safe and controlled transfer between utility and generator power.
Switching Between Mains and Standby Power:

Image 5.1: Diagram illustrating the easy switching mechanism between mains power (electric company) and backup power (generator) to supply electricity to the house or electrical equipment.
- To transfer from Utility (Mains) to Generator Power:
- Ensure the generator is running and stable.
- Move the transfer switch handle from the 'ON' (Utility) position to the 'OFF' (Center) position. This disconnects the load from the utility.
- Wait a few seconds for any residual power to dissipate.
- Move the handle to the other 'ON' (Generator) position. The load will now be powered by the generator.
- To transfer from Generator to Utility (Mains) Power:
- Ensure utility power has been restored and is stable.
- Move the transfer switch handle from the 'ON' (Generator) position to the 'OFF' (Center) position. This disconnects the load from the generator.
- Wait a few seconds.
- Move the handle to the original 'ON' (Utility) position. The load will now be powered by the utility.
- Shut down the generator.
Always ensure the switch is fully engaged in either the 'ON' (Utility) or 'ON' (Generator) position, or completely in the 'OFF' (Center) position. Never leave the switch in an intermediate position.
6. Maintenance
Regular maintenance helps ensure the longevity and safe operation of your transfer switch. Always disconnect all power sources before performing any maintenance.
- Annual Inspection: Have a qualified electrician inspect the transfer switch annually. This includes checking for loose connections, signs of corrosion, or damage to the enclosure and internal components.
- Cleaning: Keep the exterior of the enclosure clean and free from debris. If necessary, gently wipe internal components with a dry, non-conductive cloth after ensuring all power is off.
- Lubrication: The mechanical switching mechanism may benefit from light lubrication with a non-conductive, electrical-grade lubricant if operation becomes stiff. Consult a professional.
- Environmental Protection: Ensure the NEMA 3R enclosure remains sealed to protect internal components from moisture and dust. Check gaskets and seals for wear.
7. Troubleshooting
If you encounter issues with your OELFFOW 100A Generator Transfer Switch, consider the following common troubleshooting steps. For complex issues, contact a qualified electrician.
- No Power to Load:
- Check if the utility power is active.
- Ensure the generator is running and producing power.
- Verify the transfer switch handle is fully engaged in either the utility 'ON' or generator 'ON' position.
- Check for tripped circuit breakers in your main panel or on the generator.
- Switch Handle is Stiff:
- Do not force the handle.
- Ensure no obstructions are preventing movement.
- Consult a qualified electrician for inspection and potential lubrication.
- Unusual Noises or Smells:
- Immediately disconnect all power sources.
- Do not attempt to operate the switch.
- Contact a qualified electrician for urgent inspection.
8. Specifications
Detailed technical specifications for the OELFFOW 100A Generator Transfer Switch.

Image 8.1: Visual representation of the product dimensions and a summary of key parameters for the OELFFOW 100A Generator Transfer Switch.
| Parameter | Value |
|---|---|
| Brand | OELFFOW |
| Model Number | LBT-081-100MH-1 |
| Rated Current | 100 A |
| Rated Voltage | 120/240 VAC (also compatible with 450V systems) |
| Maximum Power | 45000W (12000W/24000W/45000W depending on voltage configuration) |
| Number of Poles | 2P (Two-Pole) |
| Phase Type | Single-phase or Three-phase (application dependent) |
| Operation Mode | ON-OFF-ON Manual Transfer |
| Mounting Type | Wall Mount |
| Material | Cold-rolled Steel Plate DC01, Metal, Plastic, T2 Electrolytic Copper |
| Enclosure Rating | NEMA 3R (Indoor/Outdoor Use) |
| Product Dimensions | 14.96 x 9.45 x 7.48 inches (approx. 38 x 24 x 19 cm) |
| Item Weight | 11.42 pounds (approx. 5.18 kg) |
9. Warranty and Support
For warranty information, technical support, or service inquiries regarding your OELFFOW 100A Generator Transfer Switch, please refer to the documentation provided at the time of purchase or contact the seller directly. Ensure you have your model number (LBT-081-100MH-1) and purchase details available when contacting support.