SongLong 800L/H-DZ

SongLong 800L/H Aquarium Pump Instruction Manual

Model: 800L/H-DZ

1. Introduction

Thank you for choosing the SongLong 800L/H Aquarium Pump. This submersible water pump is designed for various aquatic applications, including aquariums, fountains, hydroponic systems, and small ponds. Its efficient and quiet operation ensures a healthy and vibrant aquatic environment. Please read this manual thoroughly before installation and operation to ensure safe and optimal performance.

SongLong 800L/H Aquarium Pump in various applications: fish tank, fountain, hydroponics, and small pond.

Image 1.1: The SongLong 800L/H Aquarium Pump is suitable for multiple uses, including aquariums, fountains, hydroponic setups, and small ponds.

2. Safety Instructions

  • Always disconnect the power supply before performing any maintenance or cleaning.
  • Ensure the pump is fully submerged in water during operation to prevent overheating and damage.
  • Do not operate the pump with a damaged power cord or plug. If damaged, contact the manufacturer for replacement.
  • This pump is designed for fresh and saltwater applications only. Do not use with flammable or corrosive liquids.
  • Keep out of reach of children.
  • Ensure the power outlet has a proper ground connection.
  • Do not lift the pump by its power cord.

3. Package Contents

Please check the package to ensure all components are present and undamaged:

  • 1 x SongLong 800L/H Aquarium Pump
  • 1 x Water Tube (1 meter anti-deformation)
  • 2 x Nozzles (8mm and 13mm)

4. Product Features

  • High Flow Rate: 800 Liters per Hour (L/H) for efficient water circulation.
  • Adjustable Water Flow: Includes different nozzle options (8mm, 13mm) and a 1-meter anti-deformation water tube for versatile flow configurations.
  • Strong Suction Cups: Equipped with four robust suction cups for secure placement on horizontal or vertical surfaces.
  • Detachable Design: Easy to disassemble and clean without the need for additional tools.
  • Ultra-Quiet Operation: Engineered for minimal noise output.
  • Energy-Saving: Designed for efficient power consumption.
  • Long Power Cord: Features a 3-meter extra-long power cord for flexible installation.
SongLong 800L/H Aquarium Pump with 1m anti-deformation water tube and 8mm and 13mm nozzles.

Image 4.1: The pump comes with a 1-meter anti-deformation water tube and two nozzle sizes (8mm and 13mm) for varied water flow options.

SongLong 800L/H Aquarium Pump showing strong suction cups and placement options on horizontal and vertical planes.

Image 4.2: The pump features four strong suction cups for secure mounting, allowing for both horizontal and vertical placement within your aquatic setup.

5. Setup Instructions

  1. Unpack and Inspect: Carefully remove all components from the packaging. Inspect the pump, power cord, and accessories for any signs of damage.
  2. Choose Nozzle and Tube: Select the appropriate nozzle (8mm or 13mm) for your desired water flow and connect it to the pump's outlet. Attach the provided water tube if required for your application.
  3. Placement: Position the pump in your aquarium, fountain, or pond. Ensure it is fully submerged in water. Use the four strong suction cups on the bottom of the pump to secure it firmly to a clean, smooth surface, either horizontally or vertically.
  4. Power Connection: Route the 3-meter extra-long power cord safely, ensuring it does not create a tripping hazard and is not kinked. Plug the pump into a suitable, grounded electrical outlet.
Comparison of SongLong pump with 3m power cord versus another pump with a shorter cord, showing easier wiring.

Image 5.1: The SongLong pump features a 3-meter extra-long power cord, facilitating easier wiring and installation compared to pumps with shorter cords.

6. Operating Instructions

  1. Initial Start-up: Once the pump is fully submerged and connected to power, it will begin operating.
  2. Flow Adjustment: The pump's flow rate is determined by the chosen nozzle size and any connected tubing. Ensure the water flow is appropriate for your application.
  3. Continuous Operation: The pump is designed for continuous operation, provided it remains fully submerged and free from obstructions.
  4. Shut Down: To turn off the pump, simply unplug it from the power outlet.

7. Maintenance

Regular cleaning and maintenance will prolong the life and efficiency of your pump.

  1. Disconnect Power: Always unplug the pump from the power source before cleaning or performing any maintenance.
  2. Disassembly: The pump features a detachable design for easy cleaning. Gently remove the front cover, then the filter, and finally the rotor assembly. No tools are required for this process.
  3. Cleaning: Rinse all components (front cover, filter, rotor, housing, gland, outlet) under clean running water. Use a soft brush to remove any accumulated debris, algae, or mineral deposits. Pay special attention to the impeller (rotor) and its housing to ensure smooth rotation.
  4. Reassembly: Once all parts are clean, reassemble the pump in reverse order: insert the rotor, attach the gland, then the filter, and finally secure the front cover. Ensure all parts fit snugly.
  5. Regular Checks: Periodically check the power cord for any signs of wear or damage.
Exploded view of SongLong 800L/H Aquarium Pump showing detachable components: Filter, Gland, Rotor, Housing, Outlet, Front Cover. Also highlights ultra-quiet and energy-saving features.

Image 7.1: The pump's detachable design allows for easy disassembly and cleaning of its components, including the filter, rotor, and housing, without the need for tools.

8. Troubleshooting

ProblemPossible CauseSolution
Pump does not start.No power supply.
Impeller jammed.
Power cord damaged.
Check power connection and outlet.
Disconnect power, disassemble, and clean impeller.
Do not use; contact manufacturer.
Reduced water flow.Filter clogged.
Impeller dirty.
Kinked tubing.
Clean the filter.
Disconnect power, disassemble, and clean impeller.
Straighten or replace tubing.
Pump is noisy.Impeller obstructed or worn.
Pump not fully submerged.
Disconnect power, disassemble, and clean impeller. Replace if worn.
Ensure pump is completely underwater.

9. Specifications

FeatureDetail
BrandSongLong
Model Number800L/H-DZ
Manufacturer Part Number800DZUK
Product Dimensions (L x W x H)2.76" x 3.31" x 1.97"
Power SourceCorded Electric
Flow Rate800 Liters/Hour (L/H)
Included ComponentsPump, Tube, Nozzles

10. Warranty and Support

For warranty information or technical support, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

© 2023 SongLong. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.