YITAHOME MAYIHpE0Kj

YITAHOME 24000 BTU Mini Split Air Conditioner Heat Pump System User Manual

Brand: YITAHOME | Model: MAYIHpE0Kj

Product Overview

The YITAHOME 24000 BTU Mini Split Air Conditioner Heat Pump System is an energy-efficient, ductless inverter system designed for both cooling and heating. It is compatible with Wi-Fi and Alexa, making it convenient for modern homes. This system is ideal for covering areas up to 1500 sq. ft. and comes with a complete installation kit. Its advanced inverter technology contributes to significant energy savings compared to traditional models.

YITAHOME 24000 BTU Mini Split Air Conditioner Heat Pump System with indoor and outdoor units, remote, and installation accessories.

Image: The YITAHOME 24000 BTU Mini Split Air Conditioner Heat Pump System, showing the indoor unit, outdoor unit, remote control, and various installation components including copper piping, electrical cables, and insulation tape.

Key Features

  • Energy-Efficient Cooling & Heating: Features a high-powered compressor and heat pump with inverter technology, saving up to 25% energy (up to 50% vs 14 SEER2 models). Ideal for 1500 sq. ft. areas.
  • Five Operating Modes: Offers Auto, Cooling, Drying, Heating, and Fan modes, with four fan speeds (Low, Medium, High, Turbo).
  • Smart Control: Remote, Wi-Fi, and Alexa compatibility for convenient control.
  • Advanced Functions: Includes auto defrost, self-diagnosis, 135°F self-cleaning, iFEEL, 0-24h timer, sleep mode, energy-saving mode, and 'healthy' modes (negative ion, electrostatic & PM2.5 removal).
  • Quiet Operation: Runs quietly at under 50 dB, suitable for bedrooms and living spaces.
  • All-Weather Responsiveness: Operates effectively from 5°F to 118°F.
  • Optimal Airflow: Max airflow reaches 50 ft with 4D air circulation.
YITAHOME Mini Split AC remote control and a diagram showing 7 modes: Auto, Cool, Heat, Dry, Sleep, ECO, Fan, and featured functions like Display, °F/°C, 24H timer, Swing, iClean, and Health.

Image: A detailed view of the remote control and a graphic illustrating the seven operating modes and various featured functions of the YITAHOME mini split system.

Installation Guide

Proper installation is crucial for the optimal performance and longevity of your YITAHOME Mini Split Air Conditioner. It is highly recommended that installation be performed by a licensed HVAC professional.

1. Preparation and Tools

Ensure you have all necessary tools and materials before beginning the installation process. The unit ships in two packages, which may arrive separately.

  • Indoor unit, outdoor unit, remote, and installation kit.
  • Tools may include: Hole saw, Multimeter, Pipe cutter, Hex wrenches, Refrigerant (R32), Torque wrench, Adjustable wrench, Tape measure, Pressure gauge, Safety belt, Flaring tool, Bracket, Level, Phillips screwdriver, Electroprobe, Vacuum pump, Pliers, Copper tube.
YITAHOME Mini Split AC components and installation tools including indoor unit, outdoor unit, remote, copper pipes, electrical wires, and various hand tools.

Image: A comprehensive display of the YITAHOME mini split system components and the necessary tools for installation, such as wrenches, gauges, and drilling equipment.

2. Installation Environment Check

Before selecting the installation location, ensure the environment meets the following criteria:

  • No heat source or steam source nearby.
  • No obstructions around the inlet and outlet of both indoor and outdoor units.
  • No smoke or oil in the vicinity.
  • No flammable, explosive, or corrosive gases present.

3. Indoor Unit Installation

The indoor unit must be installed on a hard, flat, and firm wall to prevent vibration and noise. Ensure adequate clearance:

  • To ceiling: > 15cm
  • To obstacle (sides): > 20cm
  • To floor: 230-260cm

Mounting Plate Installation:

  1. Put the mounting plate on the wall and use a level to make it horizontal.
  2. Select the position for at least 5 screws on the plate.
  3. Punch holes in the wall.
  4. Use expansion screw kits to firmly fix the plate to the wall. Do not use nails.

Drill Wall Hole for Piping:

  • After determining where the pipe will go through the wall, drill holes.
  • When drilling, ensure to avoid wires, plumbing, gas, and other sensitive components.
  • The wall hole should be inclined outward by 5-10°, with a diameter of 60-80mm.
  • Use an anti-dust bag to avoid dust when drilling.

Connection Cable Installation:

  1. Pass the power cable out from the back of the indoor unit and fix it on the terminal board.
  2. Fix the cable with a clamp.

Knock-out Panel:

  • According to piping direction, remove the knock-out panel with a knife, and remove burrs to prevent the drain pipe from being broken.

Refrigerant Piping Connection:

  1. Use both hands to turn the pipe in the desired direction. It is forbidden to operate with one hand, which will make the tube deform and rupture.
  2. Aim at the pipe center, tighten the taper nut with fingers, then tighten the taper nut with 2 wrenches.
  3. It's better to use a torque wrench to tighten the taper nut. Refer to the provided torque table for specific values based on pipe size.

Drain Hose Installation:

  • Connect the drain hose with the water outlet pipe, and fix it firmly with adhesive tape. The length should be more than 5cm to prevent water leakage.

Wrap the Piping:

  • Wrap refrigerant piping, wires, and drain pipe with wrapping tape.

Mount Indoor Unit:

  • Put the refrigerant piping out of the wall hole.
  • Put the indoor unit on the mounting plate.
  • Push the lower part of the indoor unit until a 'click' sound is heard to make sure the indoor unit is firmly fixed to the wall.

Pipe Protecting Ring and Putty:

  • To protect piping and wires, a pipe protecting ring shall be installed sealed with putty.

4. Outdoor Unit Installation

The outdoor unit must be installed in a firm and flat place to prevent vibration and noise. Ensure adequate clearance:

  • To the obstruction (top): > 20cm
  • Air in side: > 10cm
  • To the obstruction (sides): > 30cm
  • Air out side: > 200cm

Install Outdoor Unit Bracket:

  • If installing the air conditioner to a higher place, the operator should wear a safety belt and helmet.
  • Use a level to ensure the bracket is horizontal and vertical.
  • Use at least 6 expansion bolts to make sure brackets are fixed firmly on the wall.

Mount Outdoor Unit:

  • Put the outdoor unit onto the brackets.
  • Use 4 screws to fix the feet of the outdoor unit.

Connect Refrigerant Piping:

  1. Remove the nut from the stop valves.
  2. Aim at the pipe center of the stop valve, tighten the taper nut with fingers.
  3. Screw 2 caps.
  4. Tighten the taper nut with 2 wrenches. It's better to use a torque wrench to tighten the taper nut. Refer to the provided torque table for specific values based on pipe size.

Attention:

When the length of the connecting pipe is changed, extra amount of refrigerant needs to be added or reduced, so that the operation and performance of the air conditioner will not be compromised.

Length of connection pipeAdded or reduced refrigerantAmount of refrigerant for the unit
<3mCC≤12000Btu: reduce 20g/m
CC≥18000Btu: reduce 50g/m
≤1Kg
≤2Kg
3-5mNot needed
5-15mCC≤12000Btu: add 20g/m
CC≥18000Btu: add 30g/m
≤1Kg
≤2Kg

Electrical Wiring:

  1. Remove the electrical box cover.
  2. Fix cables to the terminal board according to the wiring diagram on the E-parts cover. Must follow the wiring diagram inside the box cover.
  3. Use a clamp to fix cables.
  4. Put the electrical box cover back.

Vacuumize:

  1. Before vacuuming, check all the nuts of the indoor and outdoor unit are tightened.
  2. Connect the stop valve, charging hose, manifold valve, and vacuum pump as shown in the diagram.
  3. Turn on handle Lo to vacuumize.
  4. Vacuum for 15 minutes at least, make sure the value on the pressure gauge is ≤0.1MPa.
  5. Keep pressure for 3-5 minutes after vacuumizing, ensure pressure springback ≤0.05MPa.
  6. Open 1/4 liquid valve, and remove the charging hose.
  7. Open all the liquid valves and gas valves.
  8. Screw all the caps and tighten up.

Video: This video provides a detailed step-by-step guide on how to install the YITAHOME Inverter Ductless Mini Split AC and Heater system, covering tool preparation, indoor and outdoor unit mounting, piping, electrical connections, and vacuuming procedures.

Trial Operation

After installation, perform a trial operation to ensure proper functioning and safety.

  • Electrical Safety Check: Use a multimeter to test possible leaking positions of the outdoor unit shell during trial operation. If there is electricity leakage, turn off power immediately to do further examination.
  • Water Drain and Leakage Test: Remove one filter from the indoor unit. Pour in 500ml water along the evaporator for about 20 seconds. Check if water drain can normally flow out and if any water leakage is around the indoor unit.

Maintenance

Regular maintenance ensures the efficiency and longevity of your air conditioner.

  • The air filter is removable and washable. It should be cleaned monthly to maintain optimal performance and air quality.
  • The unit features a 135°F self-cleaning function for internal sanitation.

Specifications

SpecificationValue
ManufacturerYITAHOME
Part NumberMAYIHpE0Kj
Item Weight32.6 pounds
Product Dimensions8.8 x 37 x 12.4 inches
Item model numberMAYIHpE0Kj
ColorWhite
Style24000 BTU 208-230V / 18.5 SEER2 -- WiFi
MaterialIron, Aluminum, Plastic
Voltage220 Volts
Wattage2100 watts
Installation MethodSplit System
Item Package Quantity1
Sound Level50 dB
Special FeaturesAir Purification Filter, Auto Clean, Dehumidifier, Heating & Cooling Function, Inverter Compressor, Remote Controlled, Sleep Mode, WiFi Enabled
Included ComponentsOutdoor unit, indoor unit and mounting accessories
Batteries Required?No
Capacity2 Tons
Cooling Power24000 British Thermal Units
BEE Star Rating5 Star
Start year2025
Seasonal Energy Efficiency Ratio (SEER)18.5

Warranty and Support

Your YITAHOME Mini Split Air Conditioner comes with a comprehensive warranty:

  • Parts Warranty: 5 years
  • Compressor Warranty: 7 years

For any missing or damaged parts, or to troubleshoot technical issues, please contact the manufacturer directly. YITAHOME focuses on continuous innovation to enhance energy efficiency and user experience, delivering high-performance solutions.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.