OEMIRY OM-ROF03

OEMIRY Alkaline UV Reverse Osmosis System User Manual

Model: OM-ROF03

1. Introduction

Thank you for choosing the OEMIRY Alkaline UV Reverse Osmosis System. This advanced tankless water filtration system is designed to provide clean, safe, and healthy drinking water for your household. Featuring an 8-stage filtration process, including UV sterilization and alkaline remineralization, it effectively removes over 99.99% of contaminants while enhancing water taste and restoring essential minerals.

This manual provides comprehensive instructions for the proper installation, operation, and maintenance of your new water filtration system. Please read it thoroughly before beginning installation or use to ensure optimal performance and longevity of the product.

2. What's in the Box

Carefully unpack all components and verify that all items are present and undamaged. If any items are missing or damaged, please contact OEMIRY customer support.

  • RO Water Filter System Unit
  • Faucet
  • UV Sterilizer
  • Drain Saddle
  • Inlet Hose
  • Outlet Hose
  • Replacement Filters (Pre-installed or separate, refer to packaging)
  • Instruction Manual (This document)
OEMIRY Alkaline UV Reverse Osmosis System with faucet and four filter cartridges

Image: The OEMIRY Alkaline UV Reverse Osmosis System, showing the main unit with four filter cartridges (Alkaline, RO, CTO, PP) and the accompanying faucet.

3. Specifications

FeatureDetail
Model NumberOM-ROF03
Product Dimensions16.7 x 5.1 x 15.7 inches
Weight21.9 Pounds
MaterialStainless Steel
Filtration Stages8-Stage (PP, CTO, RO, ALK, UV Sterilizer)
Purified Water Output (GPD)500 Gallons Per Day
Pure to Drain Ratio2:1
Input Voltage120V-240V

The system is designed for under-sink installation, offering a tankless design to save space and prevent secondary contamination.

Diagram illustrating the 8-stage filtration process and contaminants removed

Image: A visual representation of the 8-stage filtration process, highlighting the removal of various contaminants such as PFOA, PFOS, Lead, Fluoride, Chlorine, and TDS.

4. Setup and Installation

Proper installation is crucial for the optimal performance of your RO system. Please follow these guidelines carefully.

4.1 Pre-Installation Checklist

  • Power Outlet: Ensure a 120V-240V power socket is available under your kitchen sink for the UV sterilization system.
  • Space Requirements: The system dimensions are 16.7''x5.1''x15.7''. Verify that there is sufficient space under your sink to accommodate the filter unit.
  • Clearance: Leave at least 5 inches of space around the unit where water pipes need to be connected for normal installation and future maintenance.
  • Drainage: Confirm there is a sewage outlet and appropriate tools/connections for the sewage pipe under the sink. The system has three water outlets: inlet, purified water outlet, and sewage outlet.

4.2 Installation Steps (Overview)

  1. Turn off the main water supply to your sink.
  2. Install the dedicated faucet on your sink countertop.
  3. Connect the inlet hose to your cold water supply line.
  4. Install the drain saddle on the drain pipe for the waste water line.
  5. Connect the purified water outlet hose from the system to the new faucet.
  6. Connect the waste water hose from the system to the drain saddle.
  7. Plug in the power adapter for the UV sterilizer.
  8. Slowly turn on the main water supply and check for leaks.
  9. Flush the system as per the operating instructions before first use.
Diagram showing under-sink installation of the RO system with water purification and waste water flow

Image: An illustrative diagram demonstrating the under-sink installation of the OEMIRY RO system, detailing the connections for water purification and waste water lines.

5. Operating Instructions

Your OEMIRY RO system is designed for ease of use and automatic operation.

5.1 First Use and Flushing

Before consuming water from the system for the first time, it is essential to flush the filters to remove any carbon fines or air from the system. Open the purified water faucet and let the water run for at least 15-30 minutes, or until the water runs clear and free of air bubbles. This ensures optimal filter performance and water quality.

5.2 Daily Operation

  • To dispense purified water, simply open the dedicated RO faucet.
  • The system will automatically activate to produce purified water as needed.
  • The UV sterilization system operates automatically based on water pressure, ensuring continuous disinfection.
  • The tankless design provides fresh, on-demand purified water without storage, preventing secondary contamination.

The system can produce up to 500 gallons of purified water per day with an efficient 2:1 pure water to waste ratio, minimizing water waste compared to traditional RO systems.

6. Maintenance and Filter Replacement

Regular maintenance, particularly timely filter replacement, is vital to ensure the continuous high performance and longevity of your OEMIRY RO system.

6.1 Filter Lifespan and Replacement Schedule

The OEMIRY filters are encased in durable 5-grade stainless steel material. Only the internal filter element needs replacement, reducing overall replacement costs and extending the life of the filter housing. Actual filter life may vary based on local water conditions and usage.

Filter TypeRecommended Replacement Interval
PP Filter (Sediment)6-8 months
CTO Filter (Carbon Block)12 months
ALK Filter (Alkaline Remineralization)12 months
RO Filter (Reverse Osmosis Membrane)12-24 months

6.2 Filter Replacement Procedure

  1. Turn off the water supply to the RO system.
  2. Unplug the power adapter.
  3. Carefully unscrew the filter housing of the filter to be replaced.
  4. Remove the old filter element and dispose of it properly.
  5. Insert the new filter element, ensuring it is seated correctly.
  6. Screw the filter housing back on securely.
  7. Turn on the water supply and check for leaks.
  8. Plug in the power adapter.
  9. Flush the system for 10-15 minutes after replacing any filter to remove air and carbon fines.
Diagram showing filter stages and their recommended replacement intervals

Image: A diagram illustrating the four main filter stages (PP, CTO, RO, ALK) and their respective recommended replacement intervals for optimal performance.

7. Troubleshooting

This section provides solutions to common issues you might encounter with your OEMIRY RO system. For problems not listed here, or if solutions do not resolve the issue, please contact customer support.

7.1 Common Issues and Solutions

  • Low Water Flow:
    • Check if the main water supply valve to the system is fully open.
    • Inspect filters for clogging. Replace filters if they are past their recommended lifespan.
    • Ensure there are no kinks in the water lines.
  • Unusual Taste or Odor:
    • This often indicates that the carbon (CTO) or alkaline (ALK) filters need replacement.
    • Ensure the system was properly flushed after installation or filter replacement.
  • Water Leakage:
    • Turn off the water supply immediately.
    • Check all connections and fittings for tightness. Ensure O-rings are properly seated.
    • Inspect filter housings for cracks or damage.
  • UV Sterilizer Not Working:
    • Ensure the system is properly plugged into a functional power outlet.
    • Verify that the UV lamp is not burnt out and is correctly installed.

8. Warranty and Customer Support

OEMIRY is committed to providing high-quality products and excellent customer service. For specific warranty details regarding your OEMIRY Alkaline UV Reverse Osmosis System, please refer to the warranty card included with your product or visit the official OEMIRY website.

If you have any questions, require technical assistance, or need to order replacement parts, please do not hesitate to contact our customer support team. When contacting support, please have your product model number (OM-ROF03) and purchase date ready.

OEMIRY Customer Support:
Please refer to the contact information provided on the OEMIRY official website or your product packaging for the most up-to-date support channels.

© 2024 OEMIRY. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.