1. Introduction
This manual provides comprehensive instructions for the safe and effective operation of your Vodeson Handheld Spectrometer, model 340-1020nm. This compact and portable device is designed for precise light measurement across a wide spectral range, from 340nm to 1020nm. Please read this manual thoroughly before using the device to ensure optimal performance and longevity.
2. Safety Information
- Do not expose the device to extreme temperatures, humidity, or direct sunlight.
- Avoid dropping or subjecting the device to strong impacts.
- Do not attempt to open or modify the device. Refer all servicing to qualified personnel.
- Keep the optical sensor clean and free from dust or debris. Use a soft, lint-free cloth for cleaning.
- Ensure proper ventilation when operating the device for extended periods.
3. Package Contents
Verify that all items are present in the package:
- Vodeson Handheld Spectrometer
- User Manual (this document)
- (Additional accessories such as charging cable or protective case may be included depending on the specific product variant.)
4. Product Overview
The Vodeson Handheld Spectrometer is a compact and versatile tool for light spectrum analysis. It features a broad wavelength range and is designed for portability and ease of use with compatible devices.

Figure 4.1: The Vodeson Handheld Spectrometer connected to a smartphone, showing real-time spectral data and analysis. The device is black with a white optical sensor on the front.

Figure 4.2: Illustrates the compact and lightweight design of the spectrometer, fitting easily in the palm of a hand. Dimensions are approximately 1.85 inches (47mm) by 1.3 inches (33.2mm) by 1.1 inches (28mm).

Figure 4.3: The spectrometer offers wide compatibility with various operating systems, including Windows 8/10/11 and Android devices such as smartphones and tablets.
5. Setup
5.1 Initial Connection
- Charge the Device: If applicable, ensure the spectrometer is fully charged before first use. Connect it to a standard USB power source using the provided cable.
- Install Software/App:
- For Android devices: Download the official Vodeson Spectrometer application from the Google Play Store.
- For Windows PCs: Download the Vodeson Spectrometer software from the official Vodeson website.
- Connect the Spectrometer:
- For Android devices: Connect the spectrometer to your Android phone or tablet via a compatible USB-C to USB-C or USB-A to USB-C adapter/cable (not included, if required).
- For Windows PCs: Connect the spectrometer to an available USB port on your computer using a standard USB cable.
- Power On: Press and hold the power button (if present) until the indicator light illuminates.
5.2 Software/App Configuration
- Launch the Vodeson Spectrometer application/software on your connected device.
- The software should automatically detect the connected spectrometer. If not, check the connection and restart the application.
- Follow any on-screen prompts for initial calibration or settings adjustments.
6. Operating Instructions
6.1 Taking a Measurement
- Position the Spectrometer: Point the optical sensor of the spectrometer directly at the light source you wish to measure. Ensure there are no obstructions between the sensor and the light source.
- Open the Application: Ensure the Vodeson Spectrometer application is running and connected to the device.
- Initiate Measurement: Within the application, locate the "Measure" or "Scan" button. Tap or click it to begin the spectral analysis.
- Observe Data: The application will display the absolute spectrum, data analysis table, and other relevant parameters in real-time.

Figure 6.1: The spectrometer actively measuring a light source, with the corresponding spectral data displayed on a connected smartphone. The device is capable of measuring across a wide spectral range of 340-1020 nm.
6.2 Interpreting Measurement Data
The application provides a detailed analysis of the light spectrum. Key data points include:
- Absolute Spectrum Graph: Visual representation of light intensity across different wavelengths.
- Data Analysis Table: Numerical values for various parameters such as CIE1931 color space tristimulus values (X, Y, Z), chromaticity coordinates (x, y), and exposure time.
- Additional Parameters: Depending on the application settings, you may view color rendering index (CRI), correlated color temperature (CCT), illuminance (Lux), and specific parameters for plant growth light analysis (PAR, PPFD).

Figure 6.2: A close-up of the spectrometer application interface, displaying the absolute spectrum graph and a data analysis table with values for CIE1931 color space tristimulus and chromaticity coordinates.

Figure 6.3: A comprehensive list of measurable parameters supported by the spectrometer, categorized into Basic Parameters, Blue Light Hazard, and Plant Light Parameters, including metrics like CCT, CRI, PAR, and PPFD.
6.3 Applications
The Vodeson Handheld Spectrometer is suitable for various applications, including:
- Lighting performance evaluation
- Color rendering analysis
- Plant growth light testing
- General spectral analysis for research and industrial purposes
7. Maintenance
7.1 Cleaning
- Gently wipe the exterior of the device with a soft, dry, lint-free cloth.
- For the optical sensor, use a specialized lens cleaning cloth or air blower to remove dust. Avoid touching the sensor directly with fingers.
- Do not use abrasive cleaners, solvents, or harsh chemicals.
7.2 Storage
- Store the spectrometer in a cool, dry place, away from direct sunlight and extreme temperatures.
- If storing for an extended period, ensure the device is fully charged before storage and recharge periodically to maintain battery health.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on. | Low battery or no power. | Charge the device using the appropriate USB cable and power source. |
| Application does not detect the device. | Incorrect connection, software issue, or device not powered on. |
|
| Inaccurate readings. | Dirty sensor, improper positioning, or environmental interference. |
|
9. Specifications
| Feature | Detail |
|---|---|
| Model | 340-1020nm |
| Wavelength Range | 340-1020 nm |
| Compatibility | Windows 8/10/11, Android |
| Applications | Lighting performance evaluation, color rendering analysis, plant growth light testing, general spectral analysis. |
| Package Dimensions | 5.9 x 3.9 x 2 inches |
| Weight | 0.8 ounces |
| Manufacturer | VODESON |
| ASIN | B0FGNGL51M |
10. Warranty and Support
10.1 Warranty Information
This product comes with a standard manufacturer's warranty. Please refer to the warranty card included with your purchase or visit the official Vodeson website for detailed warranty terms and conditions. Keep your proof of purchase for warranty claims.
10.2 Customer Support
For technical assistance, troubleshooting, or any questions regarding your Vodeson Handheld Spectrometer, please contact Vodeson customer support through their official website or the contact information provided with your product documentation. When contacting support, please have your product model and ASIN (B0FGNGL51M) ready.
Related Documents - 340-1020nm
![]() |
Thorlabs Optical Spectrum Analyzers: OSA Series Overview and Specifications Explore Thorlabs' Optical Spectrum Analyzers (OSAs), featuring dual-functionality as spectrometers and wavelength meters. This document details the OSA series, covering models from 350 nm to 12.0 µm, their Fourier transform technology, key specifications, and applications in scientific research and industry. |
![]() |
LTDZ 35M-4400M Handheld Spectrum Analyzer Operation Manual This manual provides detailed information on the LTDZ 35M-4400M handheld spectrum analyzer, covering its product description, performance specifications, operational functions, working principle, and fine-tuning controls. It also includes a tutorial for customers to add a battery. |
![]() |
Dr.meter LX1330B Digital Lux Meter Instruction Manual Comprehensive instruction manual for the Dr.meter LX1330B Digital Lux Meter, covering features, specifications, operation, maintenance, and recommended illumination levels. |
![]() |
Dr.meter LX1332B Digital Lux Meter Operation Manual Comprehensive operation manual for the Dr.meter LX1332B Digital Lux Meter, covering features, specifications, panel descriptions, operation instructions, maintenance, and recommended illumination levels for various environments. |
![]() |
Stilo STI1698 Digital Clamp Multimeter User Manual User manual for the Stilo STI1698 Digital Clamp Multimeter, detailing its features, specifications, measurement procedures, safety guidelines, maintenance, and mobile app connectivity. |
![]() |
Tenmars TM-720 LUX/FC Light Meter User Manual User manual for the Tenmars TM-720 LUX/FC Light Meter, detailing its features, specifications, operation, safety precautions, recommended illumination levels, and maintenance. |
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.