1. Introduction
The Povlen TH570-Y is an advanced 5-in-1 electronic wall scanner designed to accurately detect studs, metal objects, pipes, and live AC wires behind various wall materials. This device helps users locate hidden objects before drilling, cutting, or performing other wall modifications, ensuring safety and preventing damage.

Image: The Povlen TH570-Y stud finder, highlighting its upgraded model features for improved accuracy and stability.
2. Safety Information
- Always read and understand this manual before operating the device.
- Do not rely solely on the stud finder to locate live AC wires. Always turn off power to the area before drilling or cutting into walls.
- Keep the device dry and clean. Avoid exposure to extreme temperatures or humidity.
- Do not attempt to open or modify the device. Repairs should only be performed by qualified personnel.
- Dispose of batteries responsibly according to local regulations.
3. Product Features
- Enhanced Precision and Speed: Locates edges and centers of metal, studs, joists, pipes, and live AC wires with high accuracy.
- Five Scanning Modes:
- Stud Scan: Detects wood and metal studs up to 0.5 inches (13 mm) deep.
- Deep Stud Scan 1: Detects wood and metal studs up to 1 inch (25 mm) deep.
- Deep Stud Scan 2: Detects wood and metal studs up to 1.5 inches (38 mm) deep.
- Metal Scan: Detects metal objects (e.g., rebar, pipes) up to 2.36 inches (60 mm) deep.
- AC Scan: Detects live unshielded AC wires up to 2 inches (51 mm) deep.
- Durable Design: Shock-resistant and dust-resistant for long-lasting use.
- Clear LCD Display: Backlit screen shows center and edge indications, mode, and battery status.
- Audio Alerts: Provides audible signals for detection.
- Continuous Live Wire Alert: Alerts for live AC wires in all scanning modes.

Image: Illustration of the five scanning modes (Stud 1/2", 1", 1 1/2", Metal, AC) and their respective detection depths.
4. Package Contents
- Povlen TH570-Y Stud Finder
- User Manual (this document)
- Batteries (Alkaline, pre-installed or included)
5. Setup
5.1 Battery Installation
The Povlen TH570-Y requires alkaline batteries for operation. Ensure batteries are correctly installed before use.
- Locate the battery compartment cover on the back of the device.
- Slide or open the cover.
- Insert the required batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- Close the battery compartment cover securely.
6. Operating Instructions
6.1 Power On/Off
To power on the device, press and hold the "ON/OFF" button. To power off, press and hold the "ON/OFF" button again until the display turns off, or the device will automatically power off after a period of inactivity.
6.2 Mode Selection
Press the "MODE" button to cycle through the available scanning modes: Stud 1/2", Stud 1", Stud 1 1/2", Metal, and AC. The selected mode will be indicated on the LCD display.

Image: Detailed view of the stud finder's display and buttons, including Power Button, Mode Button, Scan Button, Direction Indicator, and Mode Indicator.
6.3 Scanning Procedure
For accurate readings, the device must be calibrated against the wall surface before each scan. Calibration ensures the sensor is adjusted to the wall's density.
- Calibrate: Place the stud finder flat against the wall where you intend to start scanning. Ensure there are no studs, metal, or wires in the immediate area. Press and hold the "ON/OFF" button. Keep the device still against the wall until the calibration is complete (usually a few seconds). The display will show "CENTER" or a similar indication when ready. Release the "ON/OFF" button.
- Select Mode: Choose the appropriate scanning mode using the "MODE" button.
- Scan: While holding the "ON/OFF" button, slowly slide the device horizontally across the wall surface. Maintain constant contact with the wall.
- Detect Edge: As the device moves over the edge of a stud, the signal strength bars will increase, and an edge indicator may appear.
- Locate Center: Continue sliding until the "CENTER" indicator appears on the display, accompanied by an audio alert. This indicates the center of the stud.
- Verify and Mark: For best accuracy, scan the area from both directions and mark the center point where the "CENTER" indicator consistently appears.

Image: Step 1 of scanning: Calibrating the device by pressing the power button against a clear wall section.

Image: Step 3 of scanning: Slowly moving the stud finder across the wall surface.

Image: The stud finder indicating the edge of a stud as it is moved across the wall.

Image: The stud finder indicating the center of a stud, with a user marking the detected location.

Image: The stud finder's display showing how it indicates the exact center and edge of a stud with visual and audio alerts.
6.4 Live AC Wire Detection
The device provides continuous live AC wire alerts in all modes. If a live AC wire is detected, a specific icon (e.g., lightning bolt) will appear on the display, and an audio alert will sound. Exercise extreme caution when live wires are indicated.

Image: A user detecting a live AC wire with the stud finder, emphasizing safety before drilling.
7. Maintenance
- Cleaning: Wipe the device with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Storage: Store the stud finder in a cool, dry place away from direct sunlight and extreme temperatures. Remove batteries if storing for extended periods to prevent leakage.
- Battery Replacement: Replace batteries when the low battery indicator appears on the display to ensure optimal performance.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not turn on. | Dead or incorrectly installed batteries. | Check battery polarity or replace with new alkaline batteries. |
| Inaccurate readings or false positives. | Improper calibration; moisture in wall; presence of other materials. | Recalibrate the device on a clear section of the wall. Ensure the wall is dry. Scan from multiple directions. |
| Device constantly beeps or shows AC warning. | Live AC wires are present; high electromagnetic interference. | Proceed with extreme caution. Turn off power to the area if possible. Avoid scanning near strong electrical fields. |
| Cannot find studs in deep scan mode. | Wall material too thick; object beyond detection depth. | Ensure you are using the correct deep scan mode. Detection depth limits apply to different materials. |
9. Specifications
| Model Number | TH570-Y |
| Stud Detection Depth | Up to 1.5 inches (38 mm) |
| Metal Detection Depth | Up to 2.36 inches (60 mm) |
| Live AC Wire Detection Depth | Up to 2 inches (51 mm) |
| Power Source | Battery Powered (Alkaline) |
| Item Weight | 1.76 ounces |
| Package Dimensions | 7.76 x 3.39 x 1.65 inches |
| Color | Black-yellow |
10. Warranty and Support
10.1 Warranty Information
This product is covered by a standard manufacturer's warranty. For details regarding warranty coverage, duration, and claims, please refer to the documentation provided at the time of purchase or contact customer support.
Extended protection plans may be available for purchase separately. Please check with your retailer for options such as 3-Year or 4-Year Protection Plans.
10.2 Customer Support
For technical assistance, troubleshooting, or general inquiries about your Povlen TH570-Y Stud Finder, please contact Povlen customer support. Contact information can typically be found on the product packaging or the official Povlen website.
Manufacturer: Povlen
For online inquiries, you may visit the Povlen Store on Amazon.