1. Introduction
The OWILIWO Spa RF Radiofrequency Medical Multifunctional Device is designed for non-invasive skin care and body fat reduction. This device utilizes advanced 40KHz cavitation and radiofrequency (RF) technologies to assist in body slimming, skin tightening, and improving skin texture. This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your device.
2. Safety Precautions
Please read and understand all safety instructions before using the device. Failure to follow these guidelines may result in injury or device malfunction.
- Always clean the skin thoroughly before treatment.
- Apply a specialized gel, cream, or essential oil to the treatment area. The device requires a water-based medium for proper function and to prevent damage to the instrument.
- Do not hold the operating head stationary in one place for extended periods. Move the head continuously over the treatment area.
- Avoid direct contact with bony areas during treatment.
- Do not use disinfectant products for cleaning the device. Use a damp cotton cloth or towel.
- Ensure both the operator and the person receiving treatment remove all metal jewelry and accessories from their bodies.
- If the device is used continuously for 1 hour, allow it to rest for 10 minutes before resuming operation.
- Some individuals may experience temporary tinnitus when using the 40KHz cavitation head. This is a normal phenomenon due to the frequency range exceeding human acoustic perception.
3. Product Overview
The OWILIWO Spa RF device is a 3-in-1 system featuring a main unit and three distinct operating heads for various applications.

Image: The main unit of the OWILIWO Spa RF device with its three specialized treatment heads.
3.1 Components
- Main Control Unit with Color Touch Screen
- 40KHz Cavitation Head (for body fat reduction)
- Multipolar RF Head (typically for face and body)
- Tripolar RF Head (typically for face and eyes)
- Power Adapter

Image: Detailed view of the device's interfaces, including the touch display, output ports for the treatment heads, power switch, and fuse.
4. Setup
Follow these steps to set up your OWILIWO Spa RF device:
- Unpack all components from the packaging.
- Place the main control unit on a stable, flat surface.
- Connect the desired treatment head (40KHz Cavitation, Multipolar RF, or Tripolar RF) to its corresponding output interface on the main unit. Ensure a secure connection.
- Connect the power adapter to the device's power input and then plug it into a suitable electrical outlet.
- Turn on the device using the power switch located on the back or side of the unit.
5. Operation
The device features a user-friendly color touch screen for easy operation. It is recommended to use the device for 15-20 minutes per session, 3 times a week.
5.1 General Operation Steps
- After powering on, the touch screen will display available modes (Cavitation 40K, Tripolar RF, Multipolar RF).
- Select the desired mode by tapping on the corresponding icon.
- Adjust the energy level and treatment time using the controls on the touch screen. Start with lower energy settings and gradually increase as tolerated.
- Apply a generous amount of conductive gel, cream, or oil to the clean treatment area.
- Begin treatment by moving the selected head in slow, continuous circular or linear motions over the skin.
- Monitor skin response during treatment. If discomfort or excessive heat occurs, reduce the energy level or stop the session.
- After the session, turn off the device and clean the treatment head.
5.2 Using the 40KHz Cavitation Head
The 40KHz Cavitation head is designed for body shaping and fat reduction. It uses high-frequency sound waves to break down fat cells.

Image: Application of the 40KHz Cavitation head on a leg for body shaping.
- Application Area: Arms, legs, thighs, back, abdomen, and other body parts with localized fat.
- Function: Dissolves fat, tightens skin, enhances skin elasticity, accelerates fat cell movement, promotes intestinal and lymphatic circulation.
- Technique: Move the head in continuous circular motions over the target area.

Image: The 40KHz Cavitation head in operation, with the device's touch screen displaying settings.
5.3 Using the Tripolar RF Head
The Tripolar RF head is suitable for delicate areas like the face and eyes.

Image: Application of the Tripolar RF head on the face for skin treatment.
- Application Area: Face and eyes.
- Function: Firms and lifts skin, reduces wrinkles, shrinks pores, reduces puffiness around eyes, reduces dark circles and eye bags, improves skin texture, rejuvenates skin, and improves eye contour.
- Energy Level: Suitable for 1-2 energy settings.
5.4 Using the Multipolar RF Head
The Multipolar RF head is suitable for broader areas of the face and neck.

Image: Application of the Multipolar RF head on the face and neck area.
- Application Area: Face or neck.
- Function: Enhances skin elasticity, firms and lifts skin, reduces facial puffiness, reduces redness, improves skin texture, enhances metabolism.
- Energy Level: Suitable for 2-3 energy settings.
6. Maintenance
Proper maintenance ensures the longevity and optimal performance of your device.
- Cleaning: After each use, wipe the treatment heads and the main unit with a soft, damp cloth or wet cotton. Do not use harsh chemicals, alcohol, or abrasive cleaners. Ensure the device is powered off and unplugged before cleaning.
- Storage: Store the device and its accessories in a cool, dry place, away from direct sunlight and extreme temperatures. Keep out of reach of children.
- Inspection: Periodically inspect the power cord and treatment heads for any signs of damage. If any damage is found, discontinue use and contact customer support.
7. Troubleshooting
If you encounter any issues with your device, refer to the following common troubleshooting steps:
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on | Power cord not connected; Power outlet malfunction; Device fuse blown. | Check power cord connection; Try a different outlet; Inspect and replace fuse if necessary. |
| No sensation or heat from treatment head | Head not properly connected; Insufficient gel/oil; Energy level too low; Device malfunction. | Ensure head is securely connected; Apply more conductive gel/oil; Increase energy level gradually; Contact customer support if issue persists. |
| Screen unresponsive | Temporary software glitch. | Power off the device, wait 30 seconds, then power on again. |
| Tinnitus during 40KHz cavitation | Normal physiological response to high-frequency sound waves. | This is generally normal. If it causes significant discomfort, reduce intensity or duration. |
8. Specifications
| Feature | Detail |
|---|---|
| Brand | OWILIWO |
| Model Name | Spa RF |
| ASIN | B0F9Y8R317 |
| Manufacturer | ALMA LASERS LTD. |
| Manufacturer Reference | XinwoCA004 |
| Colour | White |
| Power Source | Wired |
| Parcel Dimensions | 37.4 x 20.7 x 20.3 cm |
| Item Weight | 1.99 kg |
| Included Components | Cavitation 40K head, Multipolar RF head, Tripolar RF head |
| Date First Available | May 27 2025 |
9. Legal Disclaimer
Actual product packaging and materials may contain more and different information than what is shown on our website. We recommend that you do not rely solely on the information presented and that you always read labels, warnings, and directions before using or consuming a product.